A. Wiring Requirements
NOTICE:
This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the
Canadian Electric
Code CSA C22.1.
• This appliance comes standard with a 110-120 VAC cord
assembly which has a female plug in to accommodate
all control options and accessories. See Figure 10.1.
This is required for proper operation of the appliance
(IntelliFire Ignition). An outlet box may be installed in a
bottom back corner of the existing solid fuel masonry or
factory built
fi
replace to plug in the cord assembly, or the
supplied power cord may be routed out onto the hearth
to a nearby outlet.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
• Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT
wire
110-120V to the valve or to the appliance wall switch. In-
correct wiring will damage controls.
• An IntelliFire
TM
Plus ignition system is standard with this
appliance.
10
10
Electrical Information
B. IntelliFire™ Plus Ignition System Wiring
• Wire an outlet box (110-120VAC) in the bottom back
corner of the existing solid fuel masonry or factory built
fi
replace to plug in the cord assembly. The supplied
cord assembly may also be routed out onto the hearth
to a nearby outlet.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 10.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire™ Plus
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the cord assembly to
supply power to the insert OR install 4 AA cell batteries
(not included) into the battery pack before use.
ON/OFF Switch
• An ON/OFF switch is included with the appliance
surround and should be attached to surround/facing.
(See Installation instructions for remote control/fronts).
• If desired an additional wall switch or thermostat may
be added to system as shown in Figure 10.1.
Figure 10.1 IPI Wiring Diagram
BLK
RED
BATTERY PACK
6V DC
GROUND
BROWN
GREEN
(MAIN)
ROCKER
SWITCH
ORANGE
(PILOT)
WALL SWITCH
OR REMOTE
INSTALL
TO CORD ASSEMBLY
120VAC
INTERMITTENT
PILOT IGNITOR
RC100 RC200 RC300
(OPTIONAL WIRELESS REMOTE CONTROLS)
TO CORD
ASSEMBLY
(110V)
WHT
ORG
MODULE
FLAME
MODULATION
AUX1 AUX2
AUX300 MODULE
FAN
BLK
RED
AUX2 NOT USED FOR INSERT MODELS.
PROTECTIVE COVER INCLUDED
GROUND
EMC FILTER UNIT