background image

GB

Specifications

Model: 

 

  LDHR018-150EKY 

 LDHR018-200EKY

Voltage (V):  

 

220-240V

~  

220-240V

~

Power consumption (W): 

1500W   

 

2000W

IP-class: 

  IP65 

  IP65

Remote 

control: 

 Yes 

  Yes

Battery 

type: 

 2xAAA 

  2xAAA

I O II Switch function

I = Standby 

Use the remote control to turn ON/OFF the heater.

II = ON   

The heater works directly without remote control.

O = OFF   

Power OFF.

Remote control instructions

  Button 

Function 

 Feature

  

 

 

ON 

Turn ON   

1. Turn ON the heater.

 

 

 

 

 

2. Receiver light in heater will turn red with 100% power  

 

      

 

 

 

output

 

 

OFF 

Turn OFF   

1. Turn OFF the heater.

 

 

 

 

 

2. The receiver light will flash in red color if the heater

 

 

 

 

 

    connects to the power supply there will be no 

 

 

 

 

 

    indication after cutting off the electricity. 

Operation instruction

• 

Remove all package material (including anti-vibration object of the lamp) and check the appliance, 

supply cord and the plug for signs of damage.

• 

Pay attention to the mounting place and all mounting material (dowels and screws). Ensure they are 

suitable and stable enough for mounting and lastingly holding of the appliance.

• 

Before mounting, the minimum safe mounting distances and tilt angles shown in the figures must be 

strictly followed.

• 

The distance between the bottom edge of the appliance and the floor must be at least 1.8 m. See 

figure 2.

• 

There must be a distance of at least 0.25 m between the appliance and the ceilings, roofs or other 

covers. See figure 2.

• 

There must be a distance of at least 0.5 m at each side between the appliance and walls or the like. 

See figure 2.

• 

Recommended degree to mounting surface is 45°.  See figure 3.

• 

Pay attention that the installation of the appliance must not add excessive wind load.

• 

First fix the mounting bracket on the wall. Ensure that the place to be installed is secure and firm if not  

install the appliance to a stand.

• 

Adjust the desired angle of radiation and tighten all screws. Check regularly the screw’s connection. 

Mechanical bearing pressure and oscillation due to wind or rain could lead to loose.

• 

Plug in the power source and operate the remote control. Then observe, whether during the first 10-

15 minutes the appliance works trouble-free.

• 

If you do not use, please remove battery socket from the remote control. 

  4     5

Summary of Contents for ECO plus-line LDHR018-150EKY

Page 1: ...Good for you and the environment Instructions Brugsanvisning Instruktions manual Ohjeet ECO plus line 1500W ECO plus line 2000W 5 Year Warranty...

Page 2: ...e heater is to be permanently connected to an electrical outlet installation must be carried out by an authorized electrician The heater can only be connected to a timer that will switch off the devic...

Page 3: ...duct is turned off due to overheating caused by improper use overheat sensor the product must be disconnected from the socket outlet and cool off Check the product for defects after 30 minutes of cool...

Page 4: ...lastingly holding of the appliance Before mounting the minimum safe mounting distances and tilt angles shown in the figures must be strictly followed The distance between the bottom edge of the appli...

Page 5: ...GB Fig 1 Fig 2 Fig 3 Fig 4 45 0 5...

Page 6: ...sevarmeren n r alle kabler er tilsluttet korrekt Terrassevarmeren m kun tilsluttes en timer der slukker for enheden efter den indstillede tid Tilslut ikke terrassevarmeren til en timer der starter ter...

Page 7: ...for at ON OFF kontakten er slukket Kontroller om r ret er spr ngt Hvis produktet er slukket p grund af overophedning for rsaget af forkert brug overophednings f ler skal produktet skal kobles fra sti...

Page 8: ...rmeren F r ops tning v r opm rksom p afstande til loft v g gulv samt vinkel p hovedet af terrassev armeren De forskrevne m l skal overholdes Se figur 2 3 Afstand mellem underkant af varmeren og gulvet...

Page 9: ...DK Figur 1 Figur 2 Figur 3 Figur 4 45 0 9...

Page 10: ...stallationen utf rs ska str mmen alltid avbrytas Sl f rst p terrassv rmaren n r alla kablar har anslutits korrekt Terrassv rmaren f r endast anslutas till en timer som st nger av enheten efter den ins...

Page 11: ...rtkopplad fr n v gguttaget och svalka Kontrollera produkten f r fel efter 30 minuter av kylning Om det inte finns n gra synliga skador f rs k att teransluta produkten again V nligen kontakta platsen f...

Page 12: ...uppm rksam p avst nd till tak v gg golv samt vinkeln p huvudet av terrassv rmaren De f reskrivna m tten ska f ljas Se figur 2 3 Avst nd mellan underkant av v rmaren och golvet ska minst vara 1 8 meter...

Page 13: ...Figur 1 Figur 2 Figur 3 Figur 4 45 0 SV 13...

Page 14: ...torasiaan Jotta v ltytt isiin paloriskilt henkil vahinkoriskilt ja s hk iskun riskilt pit l mmitint k ytett ess aina noudattaa t m n ohjeen kaikkia turvallisuusohjeita mukaan lukien seuraavat L mmitin...

Page 15: ...o Tarkista onko infrapunal mmittimen lamppu palanut Mik li infrapunal mmitin on ylikuumentumisen takia sammunut irrota verkkojohdon pistotulppa pistorasiasta ja anna laitteen j hty Tarkista laite vaur...

Page 16: ...sein n sek l mmittimen asennuskulmaan Katso kuvat 2 3 ja noudata annettuja v himm iset isyyksi Et isyyden l mmittimen rungosta lattiaan on oltava v hint n 1 8 metri Katso kuva 2 Et isyyden l mmittimen...

Page 17: ...Kuva 1 Kuva 2 Kuva 3 Kuva 4 45 0 17 FI...

Page 18: ...18 Accessories Tilbeh r Art no 212 380 Art no 212 381...

Page 19: ...19 Tillbeh r Lis varusteet Art no 212 385 Art no 212 386 Art no 212 390 Art no 212 393...

Page 20: ...Imported by importeret af NSH NORDIC A S Virkefeltet 4 8740 Br dstrup Danmark www nshnordic com Art no 212 300_212 303...

Reviews: