Heater ignites but flame is excessive
Causes:
1. Fuel pump pressure is too high.
2. Nozzle is worn.
3. Incorrect fuel.
Solutions:
1. Fuel pump pressure is too high. Attach a high pressure fuel gauge to the fuel pump and check the pump pressure. Adjust the pressure to the
manufacturer’s specifications with the adjustment on the fuel pump.
2. Nozzle is worn. With enough use, the impurities in the fuel traveling under high pressure thru the nozzle orifice can enlarge the orifice. This is
especially true when diesel fuel is used. A worn nozzle can cause the heater to run “rich” and possibly over fire the heater enough to activate the
safety thermostat and cause a shutdown. Replace after 400 hours of operation.
3. Incorrect fuel. Only use the manufacturer’s recommended fuels. Never use gasoline, paint thinner, solvents, or other flammable liquids. If you
suspect the fuel is incorrect, drain, flush and re-fill the tank with proper fuel.
13
FUEL PUMP ADJUSTMENT
1.10
1.50
80º W
80º W
80º W
12 / 174
2 Stage
P1: 10/145
P2: 20 / 290
1 Stage
12 / 174
Summary of Contents for HVF110HD
Page 5: ...5 ...
Page 7: ...7 For additional details see advanced troubleshooting page 8 pg 6 ...
Page 14: ...14 ...
Page 15: ...HVF110 Electrical Schematic For SN 21100801 and Beyond 15 ...
Page 16: ...HVF110 Breakdown Prior to SN 21100801 16 ...
Page 17: ...HVF110 Parts List Prior to SN 21100801 17 ...
Page 18: ...HVF110 Breakdown SN 21100801 to SN 21101000 18 ...
Page 20: ...20 HVF110 Breakdown For SN 21101001 and Beyond ...
Page 22: ...22 HVF210 Electrical Schematic For SN 21200801 to SN 21201201 ...
Page 26: ...HVF210 Breakdown Prior to SN 21200801 26 ...
Page 27: ...HVF210 Parts List Prior to SN 21200801 27 ...
Page 28: ...28 HVF210 Breakdown For SN 21200801 and Beyond 0 102 ...
Page 30: ...30 HVF310 Breakdown Prior to SN 21301201 ...
Page 32: ...32 HVF310 Breakdown SN 21301201 and Beyond ...
Page 33: ...HVF310 Parts List 33 Photoresistence Protection Switch Support 100 Pa Switch ...
Page 34: ...HVF410HD Electrical Schematic Prior to SN 21800800 34 ...
Page 35: ...HVF410HD Breakdown Prior to SN 21800800 35 ...
Page 37: ...HVF410HD Electrical Schematic SN 21800800 and Beyond 37 ...
Page 38: ...HVF410HD Breakdown SN 21800800 and Beyond 38 ...
Page 39: ...HVF410HD Parts List SN 21800800 and Beyond 39 ...
Page 40: ...342 N Co Rd 400 East Valparaiso IN 46383 219 464 8818 Fax 219 462 7985 www heatwagon com ...