MODEL 950H & 950HL
PROPER SET UP:
Model 950HL
is a liquid withdrawal unit. This unit
will use 11 gal of LP per hour on high fire. Use at
least (1) 200 gal. withdrawal tank. When using
Propane turn the fuel selector valve (located on the
lower manifold) to the
Propane
position. This will
insure 18 hours of continuous operation. Since the
950HL is a Liquid Propane unit, it must be set up
outside of the building. Use 3/8” or 1/2” LPG
approved hose or copper tube.
Model 950H
is a Vapor Propane or Natural Gas unit.
When using Propane turn the fuel selector valve
(located on the lower manifold) to the
Propane
posi-
tion. When using
Natural Gas
turn the selector valve
to the
Natural Gas
position. This unit can be set up indoors or out.
6
NATURAL GAS QUICK
REFERENCE HOSE
CHART
Hose
BTU
Length
1 Million
in Feet <1PSI 1PSI 2PSI 5PSI
10
1-1/2 1-1/4
3/4
3/4
25
2
1-1/4
3/4
3/4
35
2
1-1/4
3/4
3/4
50
2
1-1/4
1
3/4
75
2
1-1/4 1-1/4
3/4
100
2
1-1/4 1-1/4
3/4
125
2-1/2 1-1/2 1-1/4
1
150
2-1/2 1-1/2 1-1/4
1
175
2-1/2 1-1/2 1-1/4
1
200
2-1/2 1-1/2 1-1/4 1-1/4
225
2-1/2 1-1/2 1-1/4 1-1/4
VAPOR PROPANE QUICK
REFERENCE HOSE
CHART
Hose
BTU
Length
1 Million
in Feet 1/2PSI 10PSI
10
1-1/4 3/4
25
1-1/4 3/4
35
1-1/2 3/4
50
1-1/2 3/4
75
2
3/4
100
2
3/4
125
2
3/4
150
2
3/4
175
2
3/4
200
2
3/4
225
2
3/4