10
Vent System
Termination Kits
Vent System Components
SL D-SERIES
D-SERIES
DVK-01D
DVK-TVCD
DVK-01TRD
SLK-01D
SLK-TVCD
SLK-01TRD
Figure 6. Vent Components and Terminations
A. Vent System Approvals
These models have vent starting collars on both the top and
the back of the unit. Depending upon the installation,
decide which ONE set of starting collars will be used to
attached the vent system. The starting collar sealing cap
must remain on the starting collar NOT used.
These models use SL-D-series, direct vent components
when using the
TOP
vent collars and D-series direct vent
components when using the
REAR
vent collars.
The flame and ember appearance may vary based on
the type of fuel burned and the venting configuration used.
WARNING YOU MUST NOT MIX D-SERIES
AND SL D-SERIES COMPONENTS IN ANY
VENT SYSTEM CONFIGURATION.
Identifying Vent Components
Approved vent system components are labeled for
identification.
NO OTHER VENTING SYSTEMS OR
COMPONENTS MAY BE USED
. Detailed installation
instructions are included with each vent termination kit
and should be used in conjunction with this
Installers
Guide
. Figure 6 shows vent system components and
terminations.
The vent systems installed on this gas fireplace may
include one, two, or three 90°
elbow assemblies. The
relationships of vertical rise to horizontal run in vent
configurations using 90° elbows
MUST BE
strictly
adhered to. The rise to run relationships are shown in the
venting drawings and tables on the next several pages.
NOTE:
Two 45° elbows may be used in place of one
90° elbow. You
MUST
always maintain the
MAXIMUM
and
MINIMUM
rise-to-run ratios in the vent system
when using 45° elbows.
Step 3
Installing the
Vent System