34
3/16" (5 mm)
DSI IGNITION
IGNITOR
1/2" (13 mm)
1/2" (13 mm)
STANDING PILOT
3/8" (10 mm)
Figure 31. Gas Controls Systems
Step 6
The Gas
Supply Line
NOTE: Have the gas supply line installed by a
qualified service technician in accordance with
all building codes
.
NOTE: Before the first firing of the fireplace, the
gas supply line should be purged of any trapped
air.
NOTE: Consult local building codes to properly
size the gas supply line leading to the 1/2 inch
(13 mm) hook-up at the unit.
This gas fireplace is designed to accept a 1/2 inch
(13 mm) gas supply line.
To install the gas supply line:
A listed 1/2 inch (13 mm) manual shut-off valve
and a listed flexible gas connector are connected
to the 1/2 inch (13 mm) inlet of the control valve.
A 1/8 inch (3 mm) N.P.T. plugged tapping, acces-
sible for test gauge connection, should be pro-
vided for in the gas supply line leading to the
units shut-off valve.
Locate the gas line access hole in the outer
casing of the fireplace.
Open the fireplace lower grille, insert the gas
supply line through the gas line hole, and connect
it to the shut-off valve.
When attaching the pipe, support the control so
that the lines are not bent or torn.
After the gas line installation is complete, use a
soap solution to carefully check all gas connec-
tions for leaks.
WARNING
DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS
.