background image

5

CFX-TV36B-DSI (NG, LP) Service Parts List  /  Liste des pièces de rechange

ITEM /

PIÈCE

 DSI IGNITION

SERIAL # / N°

DE SÉRIE

PART NUMBER

/ N° DE PIÈCE

ON/OFF Wall Switch  /   Interrupteur mural Marche/Arrêt

SRV130-511

Wall Switch Cover Plate  / Cache de l'interrupteur mural

SRV130-512

High Temp Limit Switch  / Interrupteur de détection thermique

SRV60-531

Burner Tube  /  Tube de brûleur

SRV477-312

Burner Orifice NG (#34B)  /  Orifice de brûleur 

 

GN (#34B)

SRV592-800

Burner Orifice LP (#51B)  /  Orifice de brûleur 

 

PL (#51B)

SRV44-801

1

Bimetallic Flue Damper  /  Registre de tuyau bimétallique

SRV492-110A

2

Hood  /  Hotte

SRV592-243

3

Burner NG, LP  /  Brûleur GN, PL

SRV592-174A

4

Grate Assembly /  Module de Grille

SRV592-360A

5

Base Refractory  /  Réfractaire

SRV592-740

6

Refractory, Top  / Réfractaire, Dessus

SRV592-742

7

Log Set  Assembly  /  Jeu de Bûches

LOGS-TV36B

8

Log 1  /  Bûche 1

SRV446-701

9

Log 2  /  Bûche 2

SRV446-702

10

Log 3  /  Bûche 3

SRV446-703

11

Log 4  /  Bûche 4

SRV540-704

12

Log 5 

 

 /  Bûche 5

SRV560-702

13

Log 6 

 

 /  Bûche 6

SRV446-706

Junction Box  /  Boîtier de raccordement

SRV100-254A

Valve NG   /  Valve GN

SRV492-500

Valve LP   /  Valve PL

SRV492-501

Electrode  /  Électrode

SRV501-591

Module  /  Module

SRV501-592

Accessories  /  Accessoires

Make-up Air Kit  /  Module de prise d'air de compensation

AK-CFX

Remote Control Kit  /  Commande à distance

RC-STAT

Remote Control Kit  / Commande à distance

SMART-STAT

Mesh Assembly  / Module de Écran

MESH-CFX

NG Conversion Kit  /  Module de conversion au GN

NGK-TV36B

LP Conversion Kit  /  Module de conversion au propane

LPK-TV36B

Cabinet Doors  /  Portes à battant

GDA-CFXT

Bi-Fold Glass Door  /  Porte en verre pliante

GDA-CFXT-BFBK

IMPORTANT: 

THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When

ordering, supply serial and model numbers to ensure correct service parts.

Summary of Contents for CFX-TV36B

Page 1: ...derwriters Laboratories Listed 592 900F 5 00 READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE Please contact your H...

Page 2: ...he installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Firepla...

Page 3: ...tem 11 A Vent System Approvals 11 B System Components 11 C Bedroom Installation in Canada 12 D Vent Termination 12 Step 5 Positioning Leveling and Securing the Fireplace 12 Step 6 The Gas Control Syst...

Page 4: ...FX TV36B DSI NG LP Exploded Parts Diagram Vue clat e des pi ces Part number list on following page La liste des num ros de pi ce se trouve la page suivante 3 4 2 9 7 Log Set Assembly 5 8 13 12 11 10 6...

Page 5: ...ssembly Jeu de B ches LOGS TV36B 8 Log 1 B che 1 SRV446 701 9 Log 2 B che 2 SRV446 702 10 Log 3 B che 3 SRV446 703 11 Log 4 B che 4 SRV540 704 12 Log 5 B che 5 SRV560 702 13 Log 6 B che 6 SRV446 706 J...

Page 6: ...es current edition The Uniform Mechanical Code current edition and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space This model natural gas...

Page 7: ...ese instructions will void the owner s warranty and may present a fire hazard WARNING IF THERE IS ANY NOTICEABLE DAMAGE TO THE FIBER FIREBOX PLEASE CONTACT YOUR DEALER FOR FURTHER INSTRUCTIONS The Hea...

Page 8: ...8 Figure 1 Diagram of the CFX TV36B...

Page 9: ...to be measured from the unit outer wrap surface to the combustible construction NOT from the screw heads that secure the unit together Minimum Clearances from the Class B Chimney Vent Pipe to Combust...

Page 10: ...the structure where the fireplace is located It is recommended that all natural venting non air tight gas fireplaces have outside air connected to them It is also recommended that the building be mech...

Page 11: ...outlet collar Look at the vent pipe through the holes in the 10 5 8 ring to check that the vent pipe is attached NOTE It is always better to first attach a straight section of vent to the unit before...

Page 12: ...nt Termination VENT CAP 12 X ROOF PITCH IS X 12 LOWEST DISCHARGE OPENING H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Step 5 Positioning Leveling and Securing the Fireplace To properly p...

Page 13: ...hole and connect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn After the gas line installation is complete use a soap solution to carefull...

Page 14: ...nal Accessories Optional remote control kits require that 110 120 VAC be wired to the fireplace junction box WARNING TOAVOID POTENTIAL OVERHEAT ING TO THE REMOTE CONTROL RECEIVER IT MUST BE PLACED ON...

Page 15: ...aterial Installing the Trim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace but MUST NEVER overlap onto the front face The joints b...

Page 16: ...ed for faulty components Now you re ready to light the fireplace WARNING PLEASE REFER TO THE USER S MANUAL FORALL CAUTIONS SAFETY AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERATION OF TH...

Page 17: ...vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a...

Reviews: