Heat-N-Glo 6000TVB Installer'S Manual Download Page 16

20

4

Maintaining and Servicing Your Fireplace

Fireplace Maintenance

Although the frequency of your fireplace servicing and main-

tenance will depend on use and the type of installation, you

should have a qualified service technician perform an appli-

ance check-up at the beginning of each heating season.

See the table below for specific guidelines regarding each

fireplace maintenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICING

YOUR FIREPLACE.

Replacing old ember material

Frequency:

 Once annually, during the checkup.

By:

 Qualified service technician.

Task:

 Brush away loose ember material near the burner.

Replace old ember material with new dime-size and shape

pieces of Golden Ember (DE-93) and Glowing Ember (050-

721). New ember material should be placed alternately on

top of the burner - a layer of Golden Ember, a layer of

Glowing Ember, and so on. Save the remaining ember

material and repeat this procedure at your next servicing.

For more information, see 

Placing Ember Material

.

Cleaning Burner and Controls

Frequency:

 Once annually.

By:

 Qualified service technician.

Task: 

Brush or vacuum the control compartment, fireplace

logs and burner areas surrounding the logs.

Checking Flame Patterns, Flame Height
Frequency:

 Periodically.

By:

 Qualified service technician/Home owner.

Task:

 Make a visual check of your fireplace’s flame patterns.

Make sure the flames are steady - not lifting or floating.

See Figure 17. The flame sensor (DSI) or thermopile/

thermocouple (standing pilot) tips should be covered with

flame. See Figure 8.

Checking Vent System

Frequency:

 Before initial use and at least annually

thereafter, more frequently if possible.

By:

 Qualified service technician/Home owner.

Task: 

Inspect the external vent cap on a regular basis to

ensure that no debris is interfering with the flow of air. Inspect

entire vent system for proper function.

Cleaning Glass Door

Frequency:

  As necessary

By:

 Home owner.

Task: 

Clean as necessary, particularly after adding new ember

(flame colorant) material. Film deposits on the inside of the

glass door should be cleaned off using a household glass

cleaner. 

NOTE: DO NOT handle or attempt to clean the

door when it is hot and DO NOT  use abrasive cleaners.

Figure 17.

Burner Flame Patterns

MAKE SURE THE FLAMES

ARE STEADY—NOT

LIFTING OR FLOATING.

6000TVB

7000TV

Summary of Contents for 6000TVB

Page 1: ...R Underwriters Laboratories Listed 522 902F 9 00 READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE Please contact your Heat N Glo dealer for any questions or concerns For the number of your nearestHeat N Glodealer pleasecall952 985 6000 Printed in U S A Copyright 2000 Heat N Glo a division of Hearth Technologies In...

Page 2: ...the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Fireplace section of the Owners Guide DO NOT USE this appliance if any part has been under water Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control sy...

Page 3: ...4 Installing the Vent System 13 A Vent System Approvals 13 B System Components 13 C Bedroom Installation in Canada 14 D Vent Termination 14 Step 5 Positioning Leveling and Securing the Fireplace 14 Step 6 The Gas Control Systems 14 Step 7 The Gas Supply Line 15 Step 8 Gas Pressure Requirements 15 Step 9 Wiring the Fireplace 16 Step 10 Finishing 18 Step 11 Installing Trim Logs and Ember Material 18...

Page 4: ... Codes current edition The Uniform Mechanical Code current edition and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space These models natural gas and propane can be installed in a bedroom in Canada if a thermostat Model WH STAT is installed with the unit Consult local code authorities Detailed installation instructions for Model WH STAT a...

Page 5: ...t Failure to follow these instructions will void the owner s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the following actions Installation of any damaged fireplace or vent system component Modification of the fireplace or direct vent system Installation other than as instructed by Heat N Glo Improper positioning ...

Page 6: ...10 Figure 1 Diagram of the 7000TV and 6000TVB GAS ACCESS GAS CONTROLS RATING PLATES LABELS VENT COLLARS HOOD STANDOFFS BOTTOM GRILLE COVER ELECTRICAL ACCESS OUTSIDE AIR ...

Page 7: ...e inch 25mm The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the combustible construction NOT from the screw heads that secure the unit together A 42 B 38 1 2 C 22 Figure 3 Framing Dimensions Minimum Clearances from the B Type Vent Pipe to Combustible Materials is 1 inch 25mm all around the pipe Step 2 Framing the Fireplace Fireplace fram...

Page 8: ...echanically or passively balanced to allow atmospherically vented appliances such as top vented gas fireplaces with draft hoods to draft properly If the home experiences negative pressure or is likely to experience negative pressure connection to an outside air source is mandatory Installing Optional Outside Make up Air This unit is equipped to accept outside air By using outside make up air the a...

Page 9: ...h the holes in the 10 5 8 ring to check that the vent pipe is attached NOTE It is always better to first attach a straight section of vent to the unit before attaching an elbow Avoid using elbows in the vent system if possible A 90 degree elbow can be attached directly to the unit If it is it can be followed by a MAXIMUM 15 feet horizontal run a second 90 degree elbow ending in a minimum 30 foot v...

Page 10: ...ring the Fireplace To properly position level and secure the fireplace Place the fireplace into position see Figure 7 Level the fireplace from side to side and from front to back Shim the fireplace with non combustible material such as sheet metal as necessary Secure the fireplace to the framing by nailing or screwing Figure 7 Proper Positioning Leveling and Securing of a Fireplace Step 6 The Gas ...

Page 11: ...rements Pressure requirements for Heat N Glo gas fireplaces are shown in the table below Pressure Natural Gas Propane Minimum 5 0 inches 11 0 inches Inlet Pressure w c w c Maximum Inlet 14 0 inches 14 0 inches Gas Pressure w c w c Manifold 3 5 inches 10 0 inches Pressure w c w c A one eighth 1 8 inch 3 mm N P T plugged tapping is provided on the inlet and outlet side of the gas control for a test ...

Page 12: ...r chute and install the blower YOU MUST REPLACE THE AIR CHUTE AFTER INSTALLATION Remote Wall Switch Position the remote wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails WARNING DO NOT CONNECT 110 120 VAC TO THE REMOTE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED CAUTION ...

Page 13: ...ab into the pilot hole on the outer wrap Optional Accessories Optional fan and remote control kits require that 110 120 VAC be wired to the fireplace junction box Figure 12 Direct Spark Ignition DSI Wiring Diagram Remote Wall Switch Position the remote wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less of 16A W G minimum wire and connect it to the fireplace ON OFF...

Page 14: ...LES IN ANY MANNER Install optional marble and brass trim surround kits as desired Marble brass brick tile or other non combustible materials can be used to cover up the gap between the sheet rock and the fireplace Do not obstruct or modify the air inlet outlet grilles When overlapping on both sides leave enough space so that the bottom grille can be lowered and the trim door removed Positioning th...

Page 15: ... component Tampering with the fireplace components is DANGEROUS and voids all war ranties A small amount of air will be in the gas supply lines When first lighting the fireplace it will take a few minutes for the lines to purge themselves of this air Once the purging is complete the fireplace will light and will operate normally Subsequent lightings of the fireplace will not require this purging o...

Page 16: ...ly By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check of your fireplace s flame patterns Make sure the flames are steady not lifting or floating See Figure 17 The flame sensor DSI or thermopile...

Reviews: