Heat-N-Glo 6000TRXI Installer'S Manual Download Page 7

7

Getting Started

Introducing the Heat-N-Glo Gas Fireplaces

Heat-N-Glo direct vent gas fireplaces are designed to oper-
ate with all combustion air siphoned from outside of the
building and all exhaust gases expelled to the outside.

The information contained in this 

Installers Guide

, unless

noted otherwise, applies to all models and gas control
systems. Gas fireplace diagrams, including the dimensions,
are shown in this section.

Pre-install Preparation

This gas fireplace and its components are tested and safe
when installed in accordance with this 

Installers Guide

.

Report to your dealer any parts damaged in shipment,
particularly the condition of the glass. 

Do not install any

unit with damaged, incomplete, or substitute parts.

The vent system components and trim doors are shipped
in separate packages. The gas logs may be  packaged
separately and must be field installed.

Read all of the instructions before starting the
installation. Follow these instructions carefully during
the installation to ensure maximum safety and benefit.
Failure to follow these instructions will void the
owner’s warranty and may present a fire hazard.

The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo
disclaims any responsibility for, the following actions:

Installation of any damaged fireplace or vent system

component.

Modification of the fireplace or direct vent system.

Installation other than as instructed by Heat-N-Glo.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not manu-

factured and approved by Heat-N-Glo, not withstanding
any independent testing laboratory or other party approval
of such component part or accessory.

ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE
HAZARD.

When planning a fireplace installation, it’s necessary to
determine:

Where the unit is to be installed.

The vent system configuration to be used.

Gas supply piping.

Electrical wiring.

Framing and finishing details.

Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.

If the fireplace is to be installed on carpeting or tile, or on
any combustible material other than wood flooring, the
fireplace should be installed on a metal or wood panel that
extends the full width and depth of the fireplace.

Summary of Contents for 6000TRXI

Page 1: ...RENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 This appliance is only for use with the type of gas indicate...

Page 2: ...DERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the firs...

Page 3: ...lling Vent Components 19 C Vent Termination 23 Step 4 Positioning Leveling and Securing the Fireplace 25 Step 5 Install the Optional Heat Zone Kit 26 Step 6 The Gas Control Systems 26 Step 7 The Gas S...

Page 4: ...s de pi ce se trouve la page suivante 14 4 5 17 18 16 6 Log set assembly 2 3 1 15 7 8 9 10 11 12 13 19 NG LP Exploded Parts Diagram GN PL Vue clat e des pi ces Service Parts 6000TRXI Beginning Manufac...

Page 5: ...old Gasket Joint Diversifi Vari 385 410 Rheostat Knob Black Bouton de Rh ostat Noir 100 512 Flex Ball Valve Assembly Fl chir l Assembl e de Soupape de Balle 302 320A Rheostat Assembly Assembl e de Rh...

Page 6: ...absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitt...

Page 7: ...enefit Failure to follow these instructions will void the owner s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the f...

Page 8: ...LS RATING PLATE AND LABELS TRIM DOOR HOOD TOP STANDOFFS 41 1 8 1044mm 38 965mm 36 1 8 916mm 25 1 4 642mm 34 5 8 879mm 8 5 8 219mm VENT COLLARS ELECTRICAL ACCESS 26 7 8 682mm 12 3 4 323mm 3 1 2 90mm GA...

Page 9: ...tructing the Fireplace Chase A chase is a vertical box like structure built to enclose the gas fireplace and or its vent system Vertical vents that run on the outside of a building may be but are not...

Page 10: ...g material The dia gram below shows framing reference dimensions CAUTION MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING Shows center of 12 x 12 vent f...

Page 11: ...36D 5 3 4 146mm 8 3 4 222mm 11 3 4 298mm DV 48D 7 3 8 187mm 6 5 32 156mm 11 5 8 295mm 8 5 8 220mm 8 1 2 216mm 6 7 16 164mm 11 1 16 281mm 6 1 2 165mm 8 1 2 216mm 5 1 16 129mm 8 5 8 220mm 35 3 4 908mm...

Page 12: ...rminations Kits Identifying Vent Components The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tionships of vertical rise to horizontal run in...

Page 13: ...want to install the vertical baffle 385 128 See flue restrictor installation in structions Figure 6 Flex Vent The flex vent must be supported with the spacing be tween support intervals not exceeding...

Page 14: ...tem with the chart to find the appropriate position to set the Flue Restrictor 1 2 3 4 5 SETTINGS 1 2 3 4 5 Figure 10 CHART Vertical Top Vent NG Top Vent LP Rear Vent NG Rear Vent LP 4 1 1 No Restrict...

Page 15: ...MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m V H 40 MAX 12 4MM H 20 MAX 6 2m Figure 13 Venting with One 90 Elbow NOTE If a 90o elbow is first attached to the unit the maximum horizontal r...

Page 16: ...15 Venting with Two 90 Elbows VENTING WITH TWO 2 90o ELBOWS V FT H H1 FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m V H H1 40 MAX 12 4m H H1 20 MA...

Page 17: ...V H H1 H2 40 MAX 12 4 m H 8 MAX 2 48 m H H 1 H2 20 MAX 6 2 m V H H H1 H2 1 MIN 305mm 2 MAX 610mm 5 MAX 1 52m 2 MIN 610mm 4 MAX 1 22m 10 MAX 3 1m 3 MIN 914mm 6 MAX 1 86m 15 MAX 4 65m 4 MIN 1 22m 8 MAX...

Page 18: ...m V V1 H H1 40 MAX 12 4m V FT H H1 FT 1 MIN 305mm 5 MAX 1 52m 2 MIN 610mm 10 MAX 3 1m 3 MIN 914mm 15 MAX 4 65m 4 MIN 1 22m 20 MAX 6 2m H H1 20 MAX 6 2m NOTE V V1 H H1 40 MAX 12 4m Figure 17 Venting wi...

Page 19: ...NENT 1 Attach the First Vent Component to the Starting Collars To attach the first vent component to the starting collars of the fireplace WARNING THE REAR VENT COLLAR SEAL CAP MUST REMAIN ATTACHED TO...

Page 20: ...o install support brackets for horizontal runs Place the pipe supports around the vent pipe Nail the pipe supports to the framing members Figure 24 Adding Venting Components HEAT SHIELD 3 MIN 76mm COM...

Page 21: ...her interior or exterior walls Cut a 12 inch by 12 inch 305mm X 305mm hole through the wall NOTE The center of the hole is one 1 inch 25 4mm above the center of the horizontal vent pipe Position the f...

Page 22: ...g using the centerpoint previously marked Frame the hole with framing lumber the same size as the ceiling joists Figure 29 Ceiling Firestop Ceiling Side If the area above the ceiling is NOT an attic p...

Page 23: ...POSITIONED SO THAT THEARROW IS POINT ING UP For trapezoidal cap termination kits Using screws secure the cap to the exterior wall through the flanges in the cap Figure 31 Trapezoid Termination Caps WA...

Page 24: ...STRONGLY RECOMMENDED WHENEVER POSSIBLE TO USE THE VINYL PROTECTOR KIT 42 minimum for vinyl clad soffits a vent shall not terminate directly above a sidewalk or paved driveway which is located between...

Page 25: ...n and snow from the vent system Attach a flashing to the roof using nails and use a non hardening mastic around the edges of the flashing base where it meets the roof Attach a storm collar over the fl...

Page 26: ...EMUSTBEWIREDDIRECTLYTOTHEFIRE PLACE JUNCTION BOX Figure 36 Gas Controls System STANDINGPILOT Step 5 installing the Optional Heat Zone Kit NOTE There must be NO INSULATION or other com bustibles inside...

Page 27: ...gged with non combustible insulation to pre vent cold air infiltration Open the fireplace lower grille insert the gas supply line throughthegaslinehole andconnectittotheshut offvalve When attaching th...

Page 28: ...ilot Ignition Wiring Diagram Optional Accessories Optional fan and remote control kits require that 110 120 VAC be wired to the factory installed junction box before the fireplace is permanently insta...

Page 29: ...RROUND SEE THE DIAGRAM BELOW Hearth Extensions A hearth extension may be desirable for aesthetic reasons However ANSI or CAN CGAtesting standards donot require hearth extensions for gas fireplace appl...

Page 30: ...d slightly to avoid excessive flame impingement Step 11 Installing Trim Logs and Ember Material Placing the Ember Material Ember material is shipped with this gas fireplace To place the ember material...

Page 31: ...gas valve has been turned to the OFF position in which case the air would have to be purged NOTE The fireplace should be run 3 to 4 hours on the initial start up Turn it off and let it cool completely...

Page 32: ...burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check of your fireplace s flame patterns Ma...

Reviews: