Heat-N-Glo 6000TRS-AU Installation And Operation Instructions Manual Download Page 24

24

2.3

LIGHTING INSTRUCTIONS

LIGHTING INSTRUCTIONS

TO TURN OFF GAS APPLIANCE

1. Open the bottom grille.

2. Turn ON/OFF switch to "OFF".

3. Turn the valve control knob clockwise                 to

the "Pilot" position, then depress knob and
continue turning to "OFF" position.

4. Close the bottom grille.

1. "STOP!" Read the safety information on previous

page.

2. To access controls, rotate the bottom grille

down.

3. Turn the valve control knob to the "OFF" position.

To do this, you must turn the knob clockwise
to the "Pilot" position, and then press in and
continue turning clockwise                   to the
"OFF" position.

GAS CONTROL VALVE

NOTE:

Knob cannot be turned from "PILOT" to

"OFF" unless knob is pushed in slightly.  Do not
force.

4. WAIT FIVE (5)  MINUTES TO CLEAR OUT ANY

GAS.  Then smell for gas, including near the
floor.  If you then smell gas, STOP!  Follow "B"
in the safety information above. If  you don't
smell gas, go to the next step.

5. The pilot should not require accessing for lighting

purposes. The pilot is located inside the
combustion chamber.

THERMOPILE

PILOT BURNER

6. To put the control in the pilot position, turn the

control knob counter-clockwise                     to the
"Pilot" position.

7. To light the pilot depress the control knob and then

depress the red or black piezo button until it makes
a clicking sound.  It may be necessary to repeat this
step. If the pilot does not light after 10 seconds, go
back to step 3. The control knob should be held
down for a MINUTE after pilot ignition.

 • If the control knob does not pop out when

released,

STOP

-shut off the gas supply to

the heater control valve, and

IMMEDIATELY

call your service technician or gas supplier.

• If the pilot will not stay lit after two tries, turn

the control knob to the "OFF" position and
call your service technician or gas supplier.

8. After the pilot has been lit, the burner can be turned

on by turning the knob counter-clockwise

to the "ON" position. Flip the ON/

OFF switch to the "ON" position.

9. Close the bottom grille.

10. When using accessories leave rocker switch in

the "OFF" position.

‹

Summary of Contents for 6000TRS-AU

Page 1: ...4 USA 1 888 427 3973 392 900D 10 02 INSTALLATION AND OPERATION INSTRUCTIONS This product is covered by one or more of the following patents United States 4 112 913 4 408 594 4 422 426 4 424 792 4 520...

Page 2: ...nual Report to your dealer any parts dam aged in shipment specifically check glass condition The gas logs and flue system components are in sepa rate packages Read all instructions before starting ins...

Page 3: ...Installer Testing 21 2 0 OPERATING INSTRUCTIONS 21 2 1 Safety and Lighting Information 23 2 2 Safety Information 23 2 3 Lighting Instructions 24 2 4 Fan Operation 25 3 0 SERVICING AND MAINTENANCE 25 3...

Page 4: ...r remote control are desired If the heater is to be installed on carpeting or tile or on any combustible material other than wood flooring the heater should be installed on a metal or wood panel that...

Page 5: ...FIGURE 2 Heater Dimensions Locations and Space Requirements 1 1 Locating the Heater The diagram See figure 2 shows space and clearance requirements for locating a heater within a room Minimum Clearan...

Page 6: ...2 1066mm 978mm 559mm 6837mm 1054mm FIGURE3 Framing Dimensions For minimum clearances see the direct vent termination clearance diagrams on page 7 1 2 Framing the Heater Framing can be built before or...

Page 7: ...ut 300 Appliances over 50 MJ h input 500 b From the ground or above a balcony 300 c From a return wall or external corner 500 d From a gas meter M 1000 e From an electricity meter or fuse box P 500 f...

Page 8: ...UE SYSTEM Figure 5 shows straight up vertical flue system approved for use on this model STRAIGHT OUT HORIZONTAL FLUE SYSTEM Figure 6 shows straight out horizontal flue systems ap proved for use on th...

Page 9: ...M V H V FT H FT 1 MIN 305mm 4 MAX 1 22m 2 MIN 610mm 8 MAX 2 4m 3 MIN 914mm 12 MAX 3 7m 4 MIN 1 22m 16 MAX 4 9m V H 24 MAX 7 3m H 8 MAX 2 4m FIGURE8 Flueing with One 90 Elbow NOTE If a 90o elbow is fi...

Page 10: ...2 48m 3 MIN 914mm 4 MAX 1 22m 12 MAX 3 72m 4 MIN 1 22m 6 MAX 1 8m 16 MAX 4 9m 20 MAX 6 1m 6 MAX 1 8m 16 MAX 4 9m H1 V H FIGURE 10 Flueing with Two 90 Elbows V FT H H1 FT 1 MIN 305mm 4 MAX 1 22m 2 MIN...

Page 11: ...86 m 12 MAX 3 6 m 4 MIN 1 22 m 8 MAX 2 48 m 16 MAX 4 9 m 8 MAX 2 48 m 16 MAX 4 9 m NOTE V V MAX 36 10 9 m FLUEING WITH THREE 3 90 ELBOWS FIGURE11 Flueing with three 90 elbows V H H H1 H2 1 MIN 305 mm...

Page 12: ...3 MIN 914mm 12 MAX 3 7m 4 MIN 1 22m 16 MAX 4 9m NOTE H H1 16 MAX 4 9m V V1 H H1 36 MAX 10 9m V FT H H1 FT 1 MIN 305mm 4 MAX 1 22m 2 MIN 610mm 8 MAX 2 4m 3 MIN 914mm 12 MAX 3 7m 4 MIN 1 22m 16 MAX 4 9m...

Page 13: ...TOVECEMENTMUSTBEPLACED AROUNDTHEINNERPIPEHEATERSTARTING COLLARBEFOREATTACHINGTHEFIRSTFLUE COMPONENT FAILURE TO SEAL THIS JOINT MAY CAUSE THE HEATER TO OPERATE IM PROPERLY SEEFIGURE14 WARNING ENSURETHA...

Page 14: ...er of the hole is one 1 inch 25mm above the center of the horizontal flue pipe Position the firestops on both sides of the hole pre viously cut and secure the firestops with nails or screws The heat s...

Page 15: ...hole FIGURE 20 Attic Firestop C Flue Termination For Horizontal Terminations To attach and secure the termination to the last section of horizontal flue Rotate and interlock the ends as described at t...

Page 16: ...accordingly Cover the opening of the installed flue pipes Cut and frame the roof hole Use framing lumber the same size as the roof rafters and install the frame securely Flashing anchored to the frame...

Page 17: ...BRN BRN BLUE GRD BLUE JUNCTION BOX DETAIL FAN TEMPERATURE SENSOR SWITCH FAN SPEED CONTROL JUNCTION BOX 1 5 FAN These heaters have a factory installed Fan Electrical Junction Boxes variable speed Rheo...

Page 18: ...EALED A 150 C MINIMUM SEALANT MATERIAL MUST BE USED THESE JOINTS ARE NOT REQUIRED TO BE SEALED ONLY NON COMBUSTIBLE MATERIAL USING 150 C MINIMUM ADHESIVE IF NEEDED CAN BE APPLIED AS FACING TO THE FIRE...

Page 19: ...V382 701 Locate log 1 on grate with knotches and push log towards rear of firebox LOG 2 SRV382 702 Locate log 2 on grate with knotches Slide left end of log forward and right side back against tab Log...

Page 20: ...t the right end on top of log 2 LOG 5 SRV382 705 Place bottom of log 5 between the 4th and 5th grate bars rest the top onto log 1 LOG 6 SRV438 724 Place the Y shaped part of log 6 over the 3rd grate b...

Page 21: ...building WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The control system for this model is a millivolt type It consists of a gas control valve variable regulator a stand ing pilot assembly a ther...

Page 22: ...FORE THE UNIT CAN BE PLACED INTO SAFE OP ERATION DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER IMMEDIATELY CALL AQUALIFIEDSERVICETECHNICIANTOINSPECT THE UNIT AND TO REPLACEANY PART OF TH...

Page 23: ...has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the gas control system which has been under water 2 1 SAFETY LIGHTING INFORMATI...

Page 24: ...houldnotrequireaccessingforlighting purposes The pilot is located inside the combustionchamber THERMOPILE PILOTBURNER 6 To put the control in the pilot position turn the control knob counter clockwise...

Page 25: ...and burner area surrounding the logs clean by vacuuming or brush ing at least twice a year CAUTION THE LOGS GET VERY HOT HANDLE ONLY WHEN COOL WARNING DO NOT USEABRASIVE CLEANERS ON THE GLASS DOOR AS...

Page 26: ...m the underside of the thermopile The thermopile can then be sepa rated from the pilot bracket Unscrew the pilot assembly bracket and remove NOTE When removing the pilot assembly carefully pull the el...

Page 27: ...gnitor 1 Using a match light pilot If pi lot lights turn off pilot and trig ger the red or black button again If pilot lights an improper gas air mixture caused the bad light ing and a longer purge pe...

Page 28: ...he micro switch and connect to terminal TP on the gas valve Turn green knob to pilot position depress and light pilot light If meter reading is greater than 325 m v after 30 seconds the pilot generato...

Page 29: ...llow for igni tion or the heater continues to shut off disconnect the limit switch wire from the gas valve and repeat the lighting instruc tions If the pilot and burner re main lit after the heater wa...

Page 30: ...debris or blockage 1 Adjust the log set so that the flame does not impinge on it 1 Adjust the air shutter at the base of the burner 1 Inspect the opening at the base of the burner It is imperative th...

Page 31: ...nt wholesale price defective electrical or manual components optional components or accessories and glass panels not including glass panels broken during misuse or careless handling HEAT N GLO shall n...