Keep  the  remote  controller  where its
signals  can  reach  the  receiver  of  the
indoor unit. (a distance 

with 25 ft (8m)

 is 

recommended

).

When you select the timer operation, the
remote controller automatically transmits
a signal to the indoor unit at the specified
time.
If  you keep  the  remote  controller  in  a
position   that   hinders   proper   signal
transmission, a time lag of up to 15 

minutes  

may  occur.

Location of the remote controller.

.
.

8m

The air conditioner will not operate if curtains, doors or other materials
 block the signals from the remote controller to the indoor unit.
Prevent any liquid from falling into the remote controller. Do not expose 
the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct 
sunlight, the air conditioner may not function properly. Use curtains to 
prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote controller. either move 
these appliances or consult your local dealer.

.

.

TEMP

CLOCK

SPEE

D

MODE

FA

N

SP

EED

ON

OFF

TE

MP

C

4

The remote controller uses two alkaline 

AAA 

dry

batteries (R03/LR03X2)
(1) Slide  the  cover  of  the  battery
     compartment

 out all the way until the battery                                            

     compartment is revealed

, then replace the old  

     batteries with new ones.
(2) After  step (1) is done, push the RESET 
     button.
(3) Before replacing the battery compartment
      cover, confirm that the display screen on 
      the remote controller displays "0:00" and 
      that  the colon is flashing.
  After replacing batteries, 

re

set the remote

  controller clock.

Replacing batteries

AUTO COOL DRY

 HEAT FAN

TEMP

CLOCK

TIMER ON

TIMER OFF

SPEED

AUTO LOW MED HIGH

MODE

ON

OFF

TEMP

FAN

SPEED

AIR

DIRECTION

SWING

CLOCK

ECONOMIC

RUNNING

TIMER ON

TIMER OFF

TIME ADJUST

OK

CANCEL

.

AUTO COOL DRY HEAT FAN

TEMP

CLOCK

TIMER ON
TIMER OFF

SPEED AUTO LOW MED HIGH

MODE

ON

OFF

TEMP.

FAN

SPEED

AIR

DIRECTION

SWING

CLOCK

ECONOMIC

RUNNING

TIMER ON

TIMER OFF

TIME ADJUST

OK

CANCEL

The OPERATION lamp on the display
panel

 

of the indoor unit starts flashing.

1. Mode select button (MODE)
    Select AUTO.
2. Temperature button (TEMP.)
    Set the desired temperature. Normally,

 it is

O

O

O

    

set 

between

 

70 F

/

21 C t o 

84

F

/

2

8

C

3. ON/OFF button
    Push this button to start the air conditioner.
    The OPERATION lamp on the display
    panel of the indoor unit lights. The
    operating mode is selected in accordance
    with the room temperature and operation
    starts after approximately 3 minutes.

O

ON/OFF button
Push this button again to stop the air
conditioner.
If the AUTO mode is uncomfortable, you
can select the desired conditions manually.
When you select the AUTO mode, you do
not have to set the fan speed. The FAN
speed display will show AUTO and the fan
speed will be automatically controlled.

When you set the air conditioner in AUTO
mode, it will automatically select cooling,
heating

 

or

 

fan only operation depending 

on the room

 

temperature.

Once you select the operating mode, the
operating conditions are saved in the 
unit's microcomputer memory.
Thereafter, the air conditioner will start
operating under the same conditions 
when you simply push the ON/OFF 
button of the remote controller.

Start

Stop

2

3

1

7

.

.

F

F

AUTOMATIC OPERATION

HANDLING THE REMOTE CONTROLLER

CAUTIONS

Summary of Contents for B-VCH12FC-1

Page 1: ...Heat Controller Inc 1900 Wellworth Ave Jackson MI 49203 517 787 2100 www heatcontroller com OWNER S MANUAL Remote Controller Ceiling Cassette B VCH12FC 1 B VCH18FC 1 ...

Page 2: ...IR FUNCTIONS NAMES AND FUNCTIONS OF INDICATORS ON REMOTE CONTROLLER HANDLING THE REMOTE CONTROLLER SETTING THE CLOCK LOCK AND RESET BUTTON FUNCTION AUTOMATIC OPERATION COOL HEAT FAN ONLY OPERATION DRYING OPERATION TIMER OPERATION EXAMPLE OF TIMER SETTING ADJUSTING AIR FLOW DIRECTION CONTENTS ...

Page 3: ... that goes from AUTO COOL DRY HEAT FAN ONLY and back to AUTO Push the button to start operation push the button again to stop operation Increases the set temperature up to O 88 F Decreases the set temperature up to O O 62 F 17 C O 30 C This button is used for selecting fan speed Each time you push the button a fan speed is selected in a sequence that goes from AUTO LOW MED HIGH and back to AUTO Sl...

Page 4: ... lock mode when you want to prevent preprogrammed settings from being changed Push the LOCK button again when you want to cancel the LOCK mode In lock mode no other buttons will work Deletes all custom settings and reverts back to factory programmed settings The remote controller above drawing may have some differences from the one that you purchase Air Direction button Economy running button ON O...

Page 5: ...e setting is displayed Displayed by pushing the ON OFF button Push the ON OFF button again to disappear The current time is indicated 0 24 hours The time set for timer operation is indicated 0 24 hours Displayed by pushing the Lock button Push the Lock button again to disappear Displays the selected fan speed AUTO and three fan speed levels LOW MED HIGH can be indicated Displays AUTO when the oper...

Page 6: ...ditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer TEM P CLO CK SPE ED MOD E FAN SPE ED ON OF F TE MP C The remote controller uses two alkaline AAA dry batteries R03 LR03X2 1 Slide the cover of the battery compartment out all the ...

Page 7: ...n which side you Push Initial Setting of the Clock When replacing batteries do not use old batteries or different brands batteries otherwise it may cause the remote controller to malfunction If you do not use the remote controller for a few weeks or more remove the batteries Otherwise battery acid leakage may damage the remote controller The average battery life during normal use is approximately ...

Page 8: ... the factory program Clock When you push the OK button the clock time display stops flashing and the clock starts operating Push the CLOCK button in the battery compartment the colon in the clock display will start to flash To set the new time follow 1 and 2 of Initial Setting of the Clock Clock accuracy is within 10 seconds per day 2 OK button 3 Readjusting the Clock Static electricity or other f...

Page 9: ... it is O O O set between 70 F 21 C to 84 F 28 C 3 ON OFF button Push this button to start the air conditioner The OPERATION lamp on the display panel of the indoor unit lights The operating mode is selected in accordance with the room temperature and operation starts after approximately 3 minutes O ON OFF button Push this button again to stop the air conditioner If the AUTO mode is uncomfortable y...

Page 10: ...1 3 and 4 to select this mode 1 Mode select button MODE Select DRY 2 Temperature button TEMP Push the TEMP Button The fan speed indicator displays AUTO The Indoor fan speed will be automatically selected LOW 3 ON OFF button Push this button to start the air conditioner The OPERATION lamp on the display panel of the indoor unit lights and operation starts after approximately 3 minutes ON OFF button...

Page 11: ...imer operation the remote controller automatically transmits the timer signal to the indoor unit at the specified time Therefore keep the remote controller in a location from which it can transmit the signal to the indoor unit properly The effective operation time set by remote controller is limited in 24 hours 1 ON OFF TIMER button Push the ON or OFF TIMER button as required The current timer set...

Page 12: ... the ON timer indicator of the remote controller 3 Push the OK button Example again next morning at 6 00 1 Push the TIMER OFF button 2 Use the TIME ADJUST button to display 23 00 on the OFF timer indicator 3 Push the TIMER ON button 4 Use the TIME ADJUST button to display 6 00 on the ON timer indicator 5 Push the OK button To stop the air conditioner at 23 00 and start it This feature is useful wh...

Page 13: ...To set the air flow direction you desire Example You can use this setting to start the air conditioner when you wake up and stop it when you leave the house to go to work To start the air conditioner at 6 00 in the morning and stop it at 8 00 1 Push the TIMER ON button 2 Use the TIME ADJUST button to display 6 00 on the ON timer indicator of the remote controller 3 Push the TIMER OFF button 4 Use ...

Page 14: ...oner for long hours with the air flow direction set downward during the cooling or dry operation Otherwise condensation may occur on the surface of the vertical air flow louver and cause dew dripping Do not move the vertical louver manually Always use the AIR DIRECTION button If you move the louver manually it may malfunction during operation If the louver malfunctions stop the air conditioner onc...

Page 15: ...15 Heat Controller Inc VCH Series Owner s Manual 04 2009 8 2012 CR058 RG11A 202055091406 ...