47
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. G • 2/13
12
Electrical Information
Figure 12.1 IPI Wiring Diagram /RC300AU
A. Wiring Requirements
NOTICE:
This appliance must be installed by a qualified
electrician in accordance with the relevant national and
local regulations.
• Wire the appliance junction box to 220-240 VAC. This is
required for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
220-240 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE:
The main supply to the appliance must have
isolation of a minimum 1/8 in. (3 mm) contact separation
in both poles.
WARNING! Risk of Injury!
The gas supply shall be shut
off prior to disconnecting the electrical power and remov-
ing batteries (if installed) before proceeding with any
maintenance to the appliance.
GREEN
(MAIN)
ORANGE
(PILOT)
8K1 WIRE
HARNESS
GROUND
CONTROL MODULE
OPTIONAL ON/OFF
WALL SWITCH
RED
BLACK
BATTERY PACK
6V DC (C X 4)
BROWN
S
I
GROUND
TO CHASSIS
TO CORD ASSEMBLY
120VAC
WALL SWITCH
JUMPER WIRE
MODULE RESET
SWITCH
WIRE ASSEMBLY
OPTIONAL
JUNCTION CORD
WHITE
ORANGE
GAS TUBE
FLAME
SENSE
IGNITOR
B. IntelliFire Plus
TM
Ignition System Wiring
• Wire the appliance junction box to 220-240 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus
TM
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the appliance OR install 4 C cell
batteries (not included) into the battery pack before use.
• An in-line isolation switch must be installed within 1
meter of the fireplace. This is required for servicing and/
or resetting the control module in the event of a control
module LOCK-OUT.
C. Optional Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
• Hearth & Home Technologies recommends that Intel-
liFire Plus
TM
wireless controls be used for their features
and functionality with the IntelliFire Plus
TM
ignition sys
-
tem
.
WARNING! Risk of Shock!
Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock!
Replace damaged wire with
type 105 ºC (221 ºF) rated wire. Wire must have high tem-
perature insulation.
NO FAN OPTION