Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. H • 11/08
19
5
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffi c and away from furniture and draperies.
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
C
B
B
TOP VENT
TOP VENT
TOP VENT
ALCOVE
INSTALLATION
D
B
A
A
F
E
Model
A
B
C
D
E
F
Minimum
SL-550TV-IPI-E
Inches
42
37
59-1/2
See Section
5.D for Alcove
Installation
16-1/4
1/2
Millimeters
1067
940
1511
413
13
SL-750TV-IPI-E
Inches
45-1/2
42
64-3/8
16-1/4
1/2
Millimeters
1156
1067
1635
413
13
SL-950TV-IPI-E
Inches
50-1/2
49
71-1/2
16-1/4
1/2
Millimeters
1283
1245
1816
413
13