![Heat & Glo RADIUS-100 Owner'S Manual Download Page 4](http://html.mh-extra.com/html/heat-and-glo/radius-100/radius-100_owners-manual_2115564004.webp)
Page
4
7076-260B · April 8, 2015
Installation
The house owner is responsible for ensuring that all neces-
sary national and local safety measures are observed during
installation and fi tting and also responsible for observing the
fi tting and operating instructions detailed in this manual.
When you install any kind of fi replace or stove, you must
inform the local authorities. You are also responsible for call-
ing in a chimney sweep to inspect and authorize the instal-
lation.
To ensure best-possible functionality and safety for your
installation, we advise you to call a professional fi tter. Our
Hearth and Home Dealer will be able to recommend a quali-
fi ed fi tter in your area. For information on Hearth and Home
Dealers, please go to www.hearthnhome.com.
All installations must comply with AS/NZS2918:2001.
This product was tested and ceritifed using a default fl ue kit
IMPORTANT: Read all instructions carefully before starting
installation. Failure to follow these instructions may result in
a fi re hazard and will void the warranty.
Safety
Any changes made to the product by the dealer, installer
or user could result in the product and safety functions not
functioning as intended. The same applies to the fi tting of
accessories or extra equipment not supplied by Hearth and
Home. This could also be the case if parts that are neces-
sary for the operation and safety of the stove are dismantled
or removed.
External surfaces of the appliance get hot during use and
can cause burns. Use caution around the unit even when
the unit does not appear to be in use. Different materials
can hold heat for different lengths of time.
In the event of a chimney fi re, keep the front door closed,
close all air controls, evacuate the structure and call the
local authorities from a safe location.
Technical data and dimensions
Materials: steel plate, cast iron, galvanized sheet, skamol
Max.
wood
length:
30
cm
Weight Radius 300:
ca. 98 kg
Weight Radius 100:
ca. 96 kg
Connecting piece internal diameter:
135 mm
Connecting piece external diameter:
148 mm
Emissions Test in compliance with AS/NZS
4012/4013
Basic data for the Radius - series
Overall Effi ciency: .............................................. 64%
Average particulate emissions: ......................... 0.8 g/kg
Average Peak Power: ...................................... 8.9 kW
Average Power per setting:
High ..................................................... 6.5 kW
Medium ................................................. 6.0 kW
Low
.......................................................
5.1
kW
Note:
Be aware of the use of exhaust fans when operating
in the same room or space as the appliance, which could
affect the draft of the appliance.
Type plates
All Heat & Glo wood-burning stoves are fi tted with a serial
plate, that specifi es the approval standards.
NOTE: This product design intent is for intermittent use and
not as a primary heat source.
TECHNICAL DATA