background image

Heat & Glo  •  MEZZO36-B/ST-B, MEZZO48-B/ST-B, MEZZO60-B/ST-B, MEZZO72-B/ST-B Owner’s Manual  •  2300-974 Rev. K  •  6/18 

6

A.  Appliance Certification

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  

This appliance is tested and approved as either supplemen-

tal room heat or as a decorative appliance.  It should not be 

factored as primary heat in residential heating calculations.

NOTICE: 

This installation must conform with local codes. 

In the absence of local codes you must comply with the 

National Fuel Gas Code, ANSI Z223.1-latest edition in 

the U.S.A. and the CAN/CGA B149 Installation Codes in 

Canada.

Product Specific Information 

 

B.  Glass Specifications

This appliance is equipped with 5 mm ceramic glass. Re

-

place glass only with 5 mm ceramic glass. Please contact 

your dealer for replacement glass.

C.  BTU Specifications

This product is listed to ANSI standards for “Vented Gas 

Fireplace Heaters” and applicable sections of “Gas Burn

-

ing Heating Appliances for Manufactured Homes and 

Recreational  Vehicles”,  and  “Gas  Fired  Appliances  for 

Use at High Altitudes”. 

Models

(U.S. or Canada)

Maximum

Input BTU/h

Minimum

Input 

BTU/h

Orifice

Size 

(DMS)

MEZZO36-B

(NG)

(0-2000 FT)

30,000

17,500

#36

MEZZO36-B

(Propane)

(0-2000 FT)

29,000

15,500 

#52

MEZZO36ST-B

(NG) 

(0-2000 FT)

30,000

17,500

#36

MEZZO36ST-B

(Propane)

(0-2000 FT)

29,000

 15,500

#52

MEZZO48-B

(NG)

(0-2000 FT)

40,000

21,000

.124

MEZZO48-B

(Propane)

(0-2000 FT)

36,000

19,500

#49

MEZZO48ST-B

(NG) 

(0-2000 FT)

40,000

21,000

.124

MEZZO48ST-B

(Propane)

(0-2000 FT)

36,000

19,500

#49

MEZZO60-B

(NG)

(0-2000 FT)

50,000

26,000

#28

MEZZO60-B

(Propane)

(0-2000 FT)

41,000

22,000

#48

MEZZO60ST-B

(NG)

(0-2000 FT)

50,000

26,000

#28

MEZZO60ST-B

(Propane)

(0-2000 FT)

41,000

22,000

#48

MEZZO72-B

(NG)

(0-2000 FT)

58,000

30,000

#23

MEZZO72-B

(Propane)

(0-2000 FT)

46,000

24,000

#45

MEZZO72ST-B

(NG)

(0-2000 FT)

58,000

30,000

#23

MEZZO72ST-B

(Propane)

(0-2000 FT)

46,000

24,000

#45

Installation and service of this appliance should be performed by 

qualified personnel. Hearth & Home Technologies recommends 

HHT Factory Trained or NFI certified professionals.

MODEL:

 MEZZO36-B, MEZZO36ST-B, 

               MEZZO48-B,MEZZO48ST-B,
               MEZZO60-B, MEZZO60ST-B, 
               MEZZO72-B, MEZZO72ST-B

LABORATORY:  

Underwriters Laboratories, Inc. (UL)

TYPE:  

Direct Vent Heater

STANDARD:

 ANSI Z21.88-2017  •  CSA 2.33-2017

Summary of Contents for MEZZO36-B

Page 1: ...gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used DO NOT store or use gasoline or other flam mable vapors and liquids in the...

Page 2: ...Sorte Sorte De De Gaz Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustm...

Page 3: ...pliance Certification 6 B Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Fai...

Page 4: ...y coverage begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the prod...

Page 5: ...ECIFIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior...

Page 6: ...ired Appliances for Use at High Altitudes Models U S or Canada Maximum Input BTU h Minimum Input BTU h Orifice Size DMS MEZZO36 B NG 0 2000 FT 30 000 17 500 36 MEZZO36 B Propane 0 2000 FT 29 000 15 50...

Page 7: ...ore information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To prevent unintended operation when not using your fire place for an extended period of time summer month...

Page 8: ...2 in 12 in APPLIANCE FRONT 165 F 150 F 140 F 130 F 125 F 125 F Figure 3 4 Wall Surface Temperatures Above Appliance MEZZO60 B MEZZO60ST B MEZZO72 B MEZZO72ST B MEASUREMENTS FROM TOP EDGE OF THE OPENIN...

Page 9: ...ireplace 2 Since every home has unique air flow characteristics and maximum allowable operating temperatures can vary from manufacturer to manufacturer and from model to model actual TV temperatures s...

Page 10: ...ing materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjust...

Page 11: ...Follow the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if...

Page 12: ...fixed glass assembly and run continuously on high an additional 12 hours This cures the materials used to manufacture the fire place NOTICE Open windows for air circulation during fire place break in...

Page 13: ...e the switch as you would under normal circumstances Wireless Remote Remote receiver is integrated into the ignition module Use the remote to turn the appliance on To preserve battery life do not use...

Page 14: ...peration without receiving a command from the RC300 remote 4 If you intend to use both an optional wired wall switch and the RC300 remote control to operate your fireplace the wall switch will overrid...

Page 15: ...mend annual service by a qualified service technician Glass Cleaning Frequency Seasonally By Homeowner Tools Needed Protective gloves glass cleaner drop cloth and a stable work surface WARNING Handle...

Page 16: ...plug on IPI models Venting Frequency Seasonally By Homeowner Tools needed Protective gloves and safety glasses Inspect venting and termination cap for blockage or obstruction such plants bird nests l...

Page 17: ...gn objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk broom flashlight vol...

Page 18: ...asive cleaner such as gas appliance glass cleaner may be nec essary See your dealer Metallic noise Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound...

Page 19: ...approximately 095 in 2 41 mm to 135 in 3 43 mm 2 Pilot won t light there is no noise or spark A No power transformer installed incorrectly or depleted batteries Verify that transformer is installed a...

Page 20: ...sensing rod to white sensor wire Polish flame sens ing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continuity with a multi meter with ohm...

Page 21: ...t feature Keep remote controls out of reach of children See your dealer if you have questions Install approved accessories per instructions included with accessories Contact your dealer for a list of...

Page 22: ..._______________________________________________________ ________________________________________________________________________________ _______________________________________________________________...

Reviews: