i30-X Linear and stretch base

Assembly instructions

Step1.
Unbox the base and identify each component
using the table on page 3.

Step 2.
Locate and position the top panel on a clean
and flat surface upside down.
The side panels are attached using the supplied
nuts (x6) which are fixed to captive welded bolts
on the inside of the top panel.

Step 3.
Identify the left and right side panels. Each side
panel will have a larger return on the front side
and bolt holes that line up to the top panel
captive bolts.

Fit the side panels one at a time by positioning
them onto the top panel first and sliding on to
the captive bolts. Then tighten the nuts as
shown.

Step 4.
Locate and position the rear panel.

The panel will fit between the base vertical return
and is fixed in place using the supplied black
screws

NOTE: A PH1 size bit is best suited to the screw
head size.

Step 5.
Locate and secure the base panel with the
supplied screws.

Once the base is secured, flip the base back
over to begin assembly of the case.

Page 4

Summary of Contents for i30-X

Page 1: ...uctions are to be used in conjunction with the general i30 X installation manual that is shipped with the unit DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE DO NOT USE OR STORE FLAMMABLE MATERIAL...

Page 2: ...ght Panel 1 5 Top Panel spigot attached 1 6 Black self tapping screws Pack of 30 1 7 Ceiling Ring 1 8 Plastic gromet 1 The fireplace will require the I30X flex liner flue kit together with 8inch solid...

Page 3: ...nel to sides 6 NOTE If installing the fireplace on either the linear or stretch base assemble the base first and then assemble the casing on top There are 4 locating holes on both part 5 top panel of...

Page 4: ...have a larger return on the front side and bolt holes that line up to the top panel captive bolts Fit the side panels one at a time by positioning them onto the top panel first and sliding on to the...

Page 5: ...e a return which will be at the back of the case Fit the side panels one at a time by positioning them to the inside lip of the base panel lining up the pre drilled holes and screwing into place using...

Page 6: ...s sitting outside the area of the top panel Excessive force may damage the finished product Step 6 Screw the top panel into place and position in the desired location for unit installation Fix the bas...

Page 7: ...g penetration gap and affix with hi temp silicone If the 8inch solid flue is passing through a ceiling space storage area or a location where blow in insulation is used add an additional 10 ventilated...

Page 8: ...nsure to use the supplied rubber gromet to protect the power cord Step 11 Straighten the unit within the casing and connect the flexible flue slide plate assembly to the unit whilst pushing the unit i...

Page 9: ...Page 9...

Page 10: ...Page 10 If an offset is required below the ceiling the painted 8inch flue must be riveted together and appropriately braced within the ceiling cavity...

Page 11: ...i30 X Freestanding Unit Dimensions Page 11 804mm 567mm 541mm 473 5mm 470mm 148 5mm 473 5mm 1 9 6 m m...

Page 12: ...i30 X Freestanding Base Dimensions LINEAR BASE STRETCH BASE...

Page 13: ...Jetmaster Heat Glo 444 Swan Street Richmond PH 1300 219 875 www jetmastervic com au...