C. Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.  If you do 

experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and 

the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.  Contact 

your dealer to arrange a service call by a qualified service technician.

IntelliFire Touch

Symptom

Possible Cause

Corrective Action

Pilot won’t light, module clicks but 

no spark 90 sec, 3 Red/1 Green 

Lock out.

Incorrect wiring.

Verify ‘S’ (White) sense wire and ‘I’ (orange) ignitor wire are 

connected to correct terminals on 

IFT-

ECM.

Loose connections or electrical 

shorts in wiring.

Verify no loose connections or electrical shorts in wiring from 

module to pilot assembly.  Verify wire insulation is not damaged.  

Verify wires are not grounding out to chassis, pilot burner, or 

any other metal object.  Replace any damaged wires. 

Ignitor gap is too large.

Verify spark gap is approximately 0.095” (2.41 mm) to 0.135” 

(3.43 mm). 

Pilot won’t light, there is no noise 

or spark.

No AC power, AC/DC adaptor 

faulty, backup batteries (if 

being used) depleted, 

IFT-

ECM slider switch in OFF 

position.

Verify 

IFT-

ECM slider switch is in ON or REM position.  Verify 

AC power available to junction box.  Verify AC/DC adaptor is 

plugged into junction box and ECM.  Verify AC/DC adaptor 

output voltage is between 5.7-6.3 Vdc.  If battery pack is used, 

check battery pack voltage is >4.2 V (if not, replace batteries). 

Shorted or loose connection 

in system wiring or wiring 

harness.

Verify system wiring configuration.  Remove and reinstall wiring  

harness  that  plugs  into  module.  Check  continuity  of  wires  in 

valve wiring harness.  Replace any damaged components. 

Poor or no system ground.

Verify black ground wire in valve harness is connected to metal 

chassis of fireplace. 

Pilot won’t light, there is no noise 

or spark, 2 Red/1 Green Lockout.

Pilot solenoid not detected.

Check  if  valve  harness  orange  wire  is  connected  to  pilot 

solenoid valve.  Check pilot solenoid resistance, nominal is 40 

ohms.  If open or shorted, replace valve.  Check valve harness 

wire continuity, if open replace 6-pin harness.

Pilot won’t light, there is no noise 

or spark, 2 Red/2 Green Lockout.

Spark coil failure.

Replace ECM.

ECM LED Error 

Codes

Description

3 Red: 1 Green

IFT-RC400 error message:  ‘Appliance Safely Disabled’, pilot sparks for 90 sec, no flame 

rectification.

2 Red: 1 Green

IFT-RC400 display:  ‘Error Pilot Flame’, pilot valve solenoid not detected.

2 Red: 2 Green

Sparking feedback signal error, spark coil failure.

5 Red: 1 Green

IFT-RC400 display:  ‘Error Power Vent’ (if installed).

Error Codes:

Troubleshooting:

See Troubleshooting matrix for more detail on Lock-out Error Codes, Possible Causes and Corrective Actions.

Summary of Contents for 6000C-IFT

Page 1: ...r See appliance installation manual for additional Commonwealth of Massachusetts requirements DO NOT store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other a...

Page 2: ...z Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approve...

Page 3: ...s 16 B Maintenance Tasks Homeowner 16 C Maintenance Tasks Qualified Service Technician 18 5 Frequently Asked Questions and Troubleshooting A Frequently Asked Questions Appliance 22 B Frequently Asked...

Page 4: ...ized HHT dealer or distributor whichever occurs earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless of the installat...

Page 5: ...or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not su...

Page 6: ...ries Inc UL TYPE Direct Vent Heater STANDARD CSA ANSI Z21 88 19 CSA 2 33 19 B Tempered Glass Specifications Hearth Home Technologies appliances manufactured with tempered glass may be installed in haz...

Page 7: ...the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To...

Page 8: ...allation site Conversions must be made by a qualified service technician using Hearth Home Technologies specified and approved parts Figure 3 3 Good Faith Wall Surface Temperatures Above Appliance D G...

Page 9: ...el to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable ope...

Page 10: ...been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that th...

Page 11: ...11 Heat Glo 6000C IFT 8000C IFT Owner s Manual 2502 981 Rev J 12 20 F Lighting Instructions IPI...

Page 12: ...control If this occurs restart the appliance NOTICE Open windows for air circulation during fire place break in Some people may be sensitive to smoke and odors Smoke detectors may activate H Heat Mana...

Page 13: ...ory installed battery pack is located in the control cavity of the appliance See Figure 3 5 Battery longevity and performance will be affected by long term exposure to the service temperatures of this...

Page 14: ...to pair the IFT ECM with the IFT ACM if installed and or IFT RC400 and IFT RC150 remote controls See the IFT RC400 or IFT RC150 installation manual for detailed instructions on pairing the IFT ECM wit...

Page 15: ...s Kit draws heat from your fireplace to an adjacent room in your home up to 20 feet away Optional Heat Out Gas Kit The Heat Out Gas heat management option is available for use with the 6000C IFT and 8...

Page 16: ...material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Any safety screen guard or barrier removed for servicing the appli ance...

Page 17: ...damage and repair as necessary Check that fireplace openings are not blocked Vacuum and dust surfaces Remote Control Frequency Seasonally By Homeowner Tools needed Replacement batteries and remote co...

Page 18: ...ded Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk...

Page 19: ...me Remove glass assembly from the appliance See Figure 4 1 Note It may be necessary to remove logs in order to clean and inspect the glass refractory Reinstall logs using instructions included in appl...

Page 20: ...ry grate and valve assemblies This task should be performed by a qualified service technician The refractory grate and base refractory do not need to be removed to service the burner assembly Figure 4...

Page 21: ...by a qualified ser vice technician The base refractory valve plate and grate do not need to be removed to access the burner assembly The logs and fiber burner top need to be removed to access the burn...

Page 22: ...s left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Metallic noise Noise is caused by metal expanding and contract...

Page 23: ...etween the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the re...

Page 24: ...r switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3 Vdc If batt...

Page 25: ...valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power...

Page 26: ...our fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have questions Instal...

Page 27: ...164 701 2 Log 2 SRV2164 702 3 Log 3 SRV2164 703 4 Log 4 SRV2164 704 5 Log 5 SRV2164 705 6 Log 6 SRV2164 706 7 Insulation Board 2166 136 8 Burner Top SRV2166 100 Y 9 Burner NG 2164 007 Y Burner Propane...

Page 28: ...GS 8C Y 1 Log 1 SRV2168 701 2 Log 2 SRV2168 702 3 Log 3 SRV2168 703 4 Log 4 SRV2168 704 5 Log 5 SRV2168 705 6 Log 6 SRV2168 706 7 Insulation Board 2170 136 8 Burner Top SRV2170 100 Y 9 Burner NG 2168...

Page 29: ...Bracket 2118 104 18 5 Flex Ball Valve Assembly SRV302 320 Y 18 6 Valve NG SRV2166 302 Y Valve Propane 2166 303 Y 18 7 Male Connector Pkg of 5 303 315 5 Y 18 8 Bulkhead W Tube SRV7000 156 Y 18 9 Jumper...

Page 30: ...or Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Exhaust Shield 385 105 Flue Restrictor Qty 2 req 385 328 Gasket Assembly 2166 081 Contains Vent Burner Neck Valve Plate LED and Adjustable Air...

Page 31: ...________________________________________________________ ________________________________________________________________________________ ______________________________________________________________...

Reviews: