background image

Heat & Glo LifeStyle Collection  •  Twilight-II  •  2087-900  Rev. G  •  12/05

30

Maintaining and Servicing Appliance

12

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service
technician should perform an appliance check-up at the beginning of each heating season.

WARNING

Annual inspection by qualified technician recommended.

Check:

• Condition of doors, surrounds and fronts.
• Condition of glass, glass assembly and glass seal.
• Obstructions of combustion and ventilation air.
• Condition of logs.
• Condition of firebox.
• Burner ignition and operation.
• Burner air shutter adjustment
• Gas connections and fittings.
• Obstructions of termination cap.

Clean:

• Glass
• Air passageways, grilles,

control compartment

• Burner, burner ports

Risk of:

• Fire
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors

Handle glass assembly with care.

NOTE:

 Clean glass after initial 3-4 hours

operation. 

Longer operation without

cleaning glass may cause a permanent
white film on glass.

CAUTION

When cleaning glass door:

• Avoid striking, scratching or slamming glass.
• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white film.
• Do NOT clean glass when hot.
• Turn off appliance after 3-4 hours of operation and

ALLOW TO COOL.

• Remove and clean glass assembly.
• Replace glass assembly and operate appliance for

additional 12 hours.

Refer to maintenance instructions.

Risk of injury or property damage.

Before servicing:

• Turn off gas.
• Turn off electricity to appliance.
• Disable remote control, if one is present.
• Ensure appliance is completely cooled.

After servicing:

• Replace any screen or barrier that was removed.
• Reseal and reinstall any venting removed for servicing.

WARNING

Inspect external vent cap regularly.
• Ensure no debris blocks cap.

WARNING

• Combustible materials blocking cap may ignite.
• Restricted air flow affects burner operation.

Summary of Contents for Twilight-II

Page 1: ...ARNING Keep children away CAREFULLY SUPERVISE children in same room as appliance Alert children and adults to hazards of high temperatures Do NOT operate with protective barriers open or removed Keep...

Page 2: ...ertinent information about your appliance Gas and Electric Information Model Number Serial Number Type of Gas The model information regarding your specific appliance can be found on the rating plate u...

Page 3: ...Certification 4 B Glass Specifications 4 C Thermal Performance Data 4 D Air Infiltration Water Resistance and Structural Tests 4 E BTU Specifications 4 F High Altitude Installations 4 G Non Combustib...

Page 4: ...ation above 4500 feet in Canada check with local authorities E BTU Specifications 1 MODEL Twilight II LABORATORY Underwriters Laboratories Inc UL TYPE Direct Vent Gas Appliance STANDARD ANSI Z21 50 20...

Page 5: ...ing tools and building supplies are available Reciprocating saw Framing material Pliers Hi temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric dril...

Page 6: ...ffic areas A Selecting Appliance Location When selecting a location for your appliance it is important to consider the required clearances to walls see Figure 3 1 Figure 3 1 Appliance Locations Model...

Page 7: ...Prevent contact with sagging or loose insulation WARNING C A B Note Framing dimensions as sume use of 1 2 inch thick wall covering materials on exterior of framing only and NO sheet rock on interior...

Page 8: ...learances to Mantels or other Combustibles above Appliance Figure 3 5 Indoor clearances to Mantel Legs or Wall Projections Acceptable on both sides of opening 12 11 10 9 8 7 6 13 5 8 12 5 8 11 5 8 10...

Page 9: ...additional termination caps Q 9 feet 1 2 x Q ACTUAL RMAX 2 caps plus appliance x QACTUAL D E L FP A H M X J or K I A G F FP FP FP FP FP B B B 60 minimum for vinyl clad soffits a appliance shall not o...

Page 10: ...all against vapor barriers or exposed insulation WARNING Do NOT notch into the framing around the appliance spacers CAUTION A Securing and Leveling the Appliance Appliance Preparation 5 Figure 5 1 Pos...

Page 11: ...non combustible for a minimum of 12 inches above and on both sides of the exterior face of the appliance This non combustible finishing material can be up to a maximum of 6 inches thick 6 inches maxi...

Page 12: ...iance provided the hole in the outer wrap does NOT exceed 2 1 2 inches in diameter and does not penetrate the firebox NOTE A listed and Commonwealth of Massachusetts ap proved 1 2 inch 13mm T handle m...

Page 13: ...n Canada check with local authorities Ensure that gas line does not come in contact with outer wrap of appliance Follow local codes Incoming gas line should be piped into the valve com partment and co...

Page 14: ...override IPI safety lockout and may cause explosion This appliance may be used with a wall switch wall mounted thermostat and or a remote control If using thermostat use one compatible with a millivol...

Page 15: ...o gas line installation Figure 7 1 Fan Wiring Diagram C Optional Accessories Optional fan and remote control kits require that 110 120 VAC be wired to the factory installed junction box before the app...

Page 16: ...n box It is highly recommended that the junction box be installed at this time to avoid reconstruction The battery pack requires two D cell batteries not included CAUTION Battery polarity must be corr...

Page 17: ...ound wires to the junc tion box as shown Add a 1 4 inch insulated female connector to the red switch leg wire route it through the knock out in the face of the junction box and connect to the top fan...

Page 18: ...D NON COMBUSTIBLE BOARD SUPPLIED ON APPLIANCE Note Measurements are in inches Interior View MEASURED FROM CORNER FIREPLACE HOOD IN TOP VIEW B Facing Material Fire Risk Do NOT obstruct air inlet or out...

Page 19: ...sing only a 300o F minimum sealant Figure 8 3 Exterior View COMBUSTIBLE SHEATHING HOUSEWRAP NON COMBUSTIBLE SHEATHING NON COMBUSTIBLE FACING 6 INCH MAXIMUM PROJECTION FROM FACE OF APPLIANCE 6 IN MAX R...

Page 20: ...inimum of 12 inches above and on both sides of the exterior face of the appli ance This non combustible finishing ma terial can be up to a maximum of 6 inches thick 6 inches maximum horizontal over ha...

Page 21: ...er placement instructions in manual Do NOT place embers directly over burner ports Replace ember material annually Explosion Risk WARNING Improperly placed embers interferes with proper burner operati...

Page 22: ...the indents on the bottom side of the log to position the large end of the log onto the grate tine as shown Position the thin end of log 1 one inch from port pattern as shown STEP 3 LOG 2 SRV2005 700...

Page 23: ...cover any port holes STEP 5 LOG 4 SRV2005 703 Locate the sharp notch on log 4 against the grate tine as shown The smooth cutout on log 4 should rest on the burner surface As with log 3 be careful not...

Page 24: ...t to ensure it is undamaged Inspect the glass for cracks chips or scratches WARNING Do NOT strike slam or scratch glass Do NOT clean glass with a razor blade Do NOT operate appliance with glass door r...

Page 25: ...injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or the gas supplier...

Page 26: ...service or maintenance can cause injury or property dam age Refer to the owner s informa tion manual provided with this ap pliance This appliance needs fresh air for safe operation and must be in stal...

Page 27: ...plug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time Property damage possible from elevated temperatures CAUTION Fire Hazard Keep comb...

Page 28: ...ction on module with ON OFF switch in ON position Acceptable readings of a good transformer are between 3 2 and 2 8 volts AC b A shorted or loose connection in wiring configuration or wiring harness R...

Page 29: ...h to OFF position Remove ignitor wire I from module Place ON OFF Rocker switch or wall switch in ON position Hold ground wire about 3 16 inch away from I terminal on module If there is no spark at I t...

Page 30: ...umes Odors Handle glass assembly with care NOTE Clean glass after initial 3 4 hours operation Longer operation without cleaning glass may cause a permanent white film on glass CAUTION When cleaning gl...

Page 31: ...and repaint as necessary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top i...

Page 32: ...7 D 43 1091 M 40 3 4 1036 E 1 2 13 N 42 1 8 1070 F 40 3 4 1035 O 23 1 2 597 G 3 3 8 86 P 35 5 8 904 H 2 1 2 64 Q 24 610 I 4 1 2 114 A Appliance Dimension Diagram Dimensions are actual appliance dimens...

Page 33: ...I 2087 900 Rev G 12 05 33 Part number list on following page NG LP Exploded Parts Diagram B Service Parts Twilight II Beginning Manufacturing Date 6 05 Ending Manufacturing Date ___ 10 Log Set Assembl...

Page 34: ...ly LOGS TWI 11 Log 1 SRV2005 701 12 Log 2 SRV2005 700 13 Log 3 SRV2005 702 14 Log 4 SRV2005 703 15 Log 5 SRV2005 704 16 Log 6 SRV2077 701 17 Log 7 SRV703 703 Lava Rock Bag 2005 790 Mineral Wool 050 72...

Page 35: ...e Assembly 593 590A 5 Pilot Assembly NG 2090 012 5 Pilot Assembly LP 2090 013 6 Valve L Bracket 674 168 7 Burner Orifice NG 32C 582 832 7 Burner Orifice LP 50C 582 850 8 Valve Bracket 2087 117 9 Flex...

Page 36: ...he Product or added thereafter are NOT covered by this warranty unless expressly authorized and approved by HEAT GLO in writing 6 Any damages caused by environmental conditions inadequate ventilation...

Page 37: ...ation Please contact your Heat Glo dealer with any questions or concerns For the number of your nearest Heat Glo dealer please call 1 888 427 3973 Printed in U S A Copyright 2005 DO NOT DISCARD THIS M...

Reviews: