background image

 

Heat & Glo Lifestyle Collection • Dakota-AU• 4036-914 Rev B • 06/07 

1

Installation & Operation 

Instructions

MODEL: Dakota-AU

Australian Gas Association 

Certi

fi

 cation Number: 7145

This manual must be used for installation and retained 
by Homeowner for operation and maintenance.

This product may be covered by one or more of the following patents: 
(United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 
5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 
5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 
6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 
6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 
2313972; (Australia) 543790; 586383; 780250, 780403, 1418504; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents 
pending.

Summary of Contents for Dakota-AU 7145

Page 1: ...5191877 5218953 5263471 5328356 5341794 5347983 5429495 5452708 5542407 5601073 5613487 5647340 5688568 5762062 5775408 5890485 5931661 5941237 5947112 5996575 6006743 6019099 6048195 6053165 6145502...

Page 2: ...his owner s manual Pay special attention to all cautions and warnings This owner s manual should be retained for future reference We suggest you keep it with your other important documents and product...

Page 3: ...A Mantel Projections 11 B Facing Material 12 8 Fireplace Setup 13 A Clean the Fireplace 13 B Grate Assembly Placement 13 C Positioning the Logs 13 D Placing Lava Rock 16 E Glass Assembly 16 F Reinstal...

Page 4: ...ervicing of this appliance should only be carried out by an authorized person in accordance with the manufacturer s instructions All relevant codes and regula tions laid down by the gas fitting author...

Page 5: ...learance Around air openings To combustibles For service access Locate fireplace away from traffic areas WARNING A Select Fireplace Location When selecting a location for your fireplace it is importan...

Page 6: ...standoffs Combustible Object 914 mm Combustible flooring may be installed next to the front of the appliance 38 mm Drywall if used 0 mm 13 mm Upper front can be covered with non combustible material...

Page 7: ...osure that includes an overhead cover and no more than two walls Figure 3 5 Two Walls and a Roof Open side at least 25 of total wall area 30 or more in total of the remaining wall area is open and unr...

Page 8: ...Leveling and Securing of a Fire place B Securing and Leveling Fireplace The diagram shows how to properly position level and se cure the fireplace see Figure 4 2 Nailing tabs are provided to secure t...

Page 9: ...below Two taps are provided on the outlet side of the gas control for a test gauge connection to measure the inlet and outlet pressures These inlet and outlet pressure taps can be ac cessed through th...

Page 10: ...K OF VALVE IGNITION MODULE 6V ON OFF WALL SWITCH VALVE FLAME SPARKER SENSOR ANT REMOTE CONTROL A Ignition System Wiring This fireplace is equipped with an electronic ignition system which operates on...

Page 11: ...ce mantels or other combustible projections above the top front edge of the fireplace Mantel B A 2 13 m minimum ceiling height Overhang 305 mm max combustible mantel depth Figure 7 1 Clearances to Com...

Page 12: ...Finishing materials must not interfere with Air flow through grilles or louvers Operation of louvers or doors Access for service WARNING B Facing Material Figure 7 2 Non combustible Facing Diagram Fir...

Page 13: ...e Logs Place right rear log on the grate against the fireplace right side wall so that its right end sits in the bracket opening Place the left rear log on the grate against the left wall and rest it...

Page 14: ...og onto the left front bar and rest its back on left rear log Place front log in front of the main grate with its left end resting on left side log as shown Figure 8 11 Front Left Log SRV722 front vie...

Page 15: ...t grate bar and rest its rear on right rear log angled towards the corner as shown Place right center log between the 4th and 5th vertical bars on the log grate resting the back on right rear log Figu...

Page 16: ...0 open them and loosen screws on top and bottom pivot pins Slide each door as necessary and tighten screws To adjust handle loosen screws to move handles as necessary and tighten screws Ashlip Rock Pa...

Page 17: ...nstructions A Before Lighting Fireplace Before operating this fireplace have a qualified technician Remove all shipping materials from inside the firebox Review proper placement of logs and lava rock...

Page 18: ...tructions accompanying fireplace CAUTION Hot while in operation Do not touch Keep children clothing furniture gasoline and other liquids having flammable vapors away Do not operate the fireplace with...

Page 19: ...you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubri cants u...

Page 20: ...utter adjustment Gas connections and fittings Clean Glass Air passageways grilles control compartment Burner burner ports Risk of Fire Delayed ignition or explosion Exposure to combustion fumes Odors...

Page 21: ...remove four screws Loosen lower pressure tap screw before attaching manometer Start up the fireplace to verify the pressure and adjust as necessary Reverse these steps to reassemble before log positi...

Page 22: ...nt Remove switch cover plate from the control box Slide access panel Replace four AA batteries Replace access panel and switch cover plate Ground Wire Control Box Switch Cover Plate Access Panel Batte...

Page 23: ...s Screw tips that have penetrated the sheet metal are sharp and should be avoided 2 Remove any foreign objects 3 Verify unobstructed air circulation Logs 1 Inspect for broken damaged or missing logs R...

Page 24: ...ction Check for spark in location along cable D Valve Replace valve Do not over tighten E Over tightened thermocouple interrupter Replace valve and thermocouple interrupter F Receiver Replace receiver...

Page 25: ...nsion Diagram Dimensions are actual fireplace dimensions Use for reference only For framing dimensions and clearances refer to Sec tion 3 Figure 12 1 Fireplace Dimensions 12 12 Reference Materials 1 2...

Page 26: ...st Service Parts Diagram Outdoor Gas Fireplace Service Parts DAKOTA AU SERIES Beginning Manufacturing Date June 2007 Ending Manufacturing Date Active 25 16 17 18 22 20 21 24 24 26 27 19 28 4 7 10 10 1...

Page 27: ...Bracket 4036 178 4036 178 1 12 Right Bottom Pivot Pin 4036 115 4036 115 1 13 Left Bottom Pivot Pin 4036 116 4036 116 1 14 Right Top Pivot Pin 4036 118 4036 118 1 15 Left Top Pivot Pin 4036 119 4036 11...

Page 28: ...AU 4036 914 Rev B 06 07 Service Parts Diagram Outdoor Gas Fireplace Service Parts DAKOTA AU SERIES Beginning Manufacturing Date June 2007 Ending Manufacturing Date Active 17 15 16 18 25 2 1 13 14 12...

Page 29: ...37 2097 137 1 8 Valve Bracket 2097 138 2097 138 1 9 Screw 4021 394 4021 394 2 10 Thermocouple Block 2098 146 2098 146 1 11 Switch Assembly 2097 145 2097 145 1 12 Compression Nut 32553 32553 1 13 Jam N...

Page 30: ...Dakota AU 4036 914 Rev B 06 07 Service Parts Diagram Outdoor Gas Fireplace Service Parts DAKOTA AU SERIES Beginning Manufacturing Date June 2007 Ending Manufacturing Date Active SRV720 SRV722 SRV723 S...

Page 31: ...e 2007 Ending Manufacturing Date Active Description of Part DAKOTA AU DAKOTA LP AU Qty req Log Set Box 1 of 3 4036 711 4036 711 1 Log SRV720 SRV720 1 Log Set Box 2 of 3 4036 712 4036 712 1 Log SRV727...

Page 32: ...32 Heat Glo Lifestyle Collection Dakota AU 4036 914 Rev B 06 07 This page intentionally left blank...

Page 33: ...Heat Glo Lifestyle Collection Dakota AU 4036 914 Rev B 06 07 33 This page intentionally left blank...

Page 34: ...914 Rev B 06 07 For Service or Replacement Parts Contact Melbourne Jetmaster 444 Swan Street Richmond 3121 03 9429 5573 Sydney Jetmaster 10 Martin Avenue Arncliff 2205 02 9597 7222 Perth Fireplace Cor...

Page 35: ...and glass panels not including glass panels broken during misuse or careless handling HEAT GLO shall not be responsible for any labor transportation or other costs Furthermore it shall not be liable f...

Page 36: ...your nearest Heat Glo LifeStyle Collection dealer please refer to page 34 of this manual or visit www heatnglo lifestyle com NOTES DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenanc...

Reviews: