Hearthstone
Quality Home Heating Products, Inc.
® Tribute Model 8040
15
I
NSTALLING
I
N
A
M
OBILE
H
OME
Follow these mandatory requirements for installing
your stove in a mobile home:
Install the stove in accordance with 24 CFR,
Part 3280 (HUD)
You must use the Tribute outside air kit
Assembly 390-53400
Ensure that the outside air inlet must remain
clear of any objects, leaves, icing, snow, or other
debris. Keep the inlet away from any exhaust
fans. The inlet requires an adequate amount of
ventilation. If the inlet becomes restricted during
operation, the unit may starve for room air,
which may cause smoke spillage and an inability
to maintain a proper fire. This smoke may set off
any smoke detectors if installed.
Permanently attach the stove to your mobile
h
ome’s floor. Use 1/4" holes in each leg base to
bolt down the stove.
Install one of the following Dura-Vent Mobile
Home Chimney & Connector Kits:
6DP-
MH 6” Diameter S/N 9096N
7DP-
MH 7” Diameter S/N 9196N
8DP-
MH 8” Diameter S/N 9296N
Each kit includes:
Stainless spark arrester cap, storm collar,
Adjustable vented flashing
– 0/12 – 6/12,
Two 24” Dura/Plus* chimney pipes, 24”
support box with built-in starter section and
trim.
* (UL or ULC approved equipment is acceptable).
Chimney must be removed when transporting
Mobile Home.
Use silicone to create an effective vapor barrier
at the location where the chimney or other
component penetrates to the exterior of the
structure.
WARNING: DO NOT INSTALL IN A SLEEPING
ROOM
CAUTION:
MAINTAIN
THE
STRUCTURAL
INTEGRITY OF THE MOBILE HOME WALLS,
FLOOR,
CEILING, AND ROOF WHILE YOUR
STOVE IS INSTALLED AND IN USE.
Figure 11