Hearthstone Quality Home Heating Products, Inc
®
Craftsbury (Model 8392)
8
I
NSTALLATION
U
NPACKING
Hearthstone packages your Craftsbury woodstove
with the greatest care so that it ships safely. Under
certain circumstances, however, damage may occur
during transit and handling. When you receive the
Craftsbury, carefully unpack and inspect the stove
and all accompanying parts. Ensure that all parts are
included inside the stove. If any parts are damaged or
missing, please contact your authorized Hearthstone
dealer immediately.
Be sure to remove the packaging material in the flue
collar and above the baffle before installing the
chimney.
P
ACK
L
IST
Craftsbury Model 8392 Woodstove
Owner’s Manual
The label is attached by a cable to the bottom of the
stove. Take care when lifting the stove not to
damage the label or cable. After final positioning of
the stove, the label may be stored in the holding clip
on the bottom shield of the stove.
Figure 2 - Label Location
I
NSTALLING
Y
OUR
S
TOVE
Choose a place to install your Craftsbury woodstove.
Consider the location of your stove for optimum
heating efficiency. In general, it is better to place your
stove in a main living area, rather than in a basement
or other confined space.
Inspect this location to make sure that the stove and
stovepipes will have the required clearance from
combustible materials that are near the stove.
Combustibles include walls, floor, ceiling, and
chimney chase. You must carefully consider the
clearances to all of these combustibles before
actually connecting your stove.
If the floor is made of combustible material, then a
non-combustible floor protector is required between
the floor and the stove. An example of a non-
combustible floor protector is a hearth constructed
with a continuous layer of tile, brick, slate, glass or
another non-combustible facing. There is no R-value
requirement.
If you use a rear connector pipe, ensure it is listed with
Underwriter’s Laboratories. Check the listing of your
pipe with UL for the correct clearances.
The diagrams in this manual represent typical
installations, but are specific to the Simpson Dura-
Vent DVL brand.
Clearances to NFPA Code 211 Protected Surfaces
You can reduce the clearances to combustible
surfaces by using any National Fire Protection
Agency (NFPA) approved wall protection system
with
additional approval of the regulatory authority having
jurisdiction in your area. Please refer to NFPA Code
211 for specifications and complete details. You can
obtain this information directly from the NFPA.
National Fire Protection Agency
Batterymarch Park
Quincy, MA 02269
1-800-344-3555
1-617-770-3000
www.nfpa.org