HearthStone Quality Home Heating Products, Inc ®
44
WFP-75 Model 8411
Note
: The
chimney chase on the roof
must be
the same size as
the flashing
.
WARNING
•
IN EVERY CASE, THE CHIMNEY MUST START WITH A
6'' DIAMETER ANCHOR PLATE SECURED TO THE
FIREPLACE. (SOLD SEPARATELY).
•
IF THE MALE NOZZLE (A) OF THE ANCHOR PLATE
EXCEEDS 2" (51 MM) IN LENGTH (SEE IMAGE BELOW),
IT SHALL BE CUT ABOVE THE LIFTING HOOKS
WELDED TO THE INSIDE OF THE FLUE OUTLET
SO THAT THE ANCHOR PLATE RESTS PERFECTLY
ON TOP OF THE FIREPLACE.
•
IF THE FLUE OUTLET IS CUT ONLY AROUND
THE HOOKS, MAKE SURE THAT THE FLUE DAMPER
MECHANISM WORKS PROPERLY BEFORE CLOSING
THE WALLS.
7.5 CHIMNEY INSTALLATION INSTRUCTIONS
Always refer to the chimney manufacturer’s Installation manual to ensure a safe installation. Some non-
illustrated parts may be required.
7.5.1 EXAMPLES OF TYPICAL CHIMNEY INSTALLATION