background image

Harman®  •  Absolute43-C Owner’s Manual_R8  •  2018 -___  •  05/20

2

3-90-00772C

Congratulations

, The Harman

®

 Absolute43-C pellet stove 

you have selected is designed to provide the utmost in safety, 

reliability, and efficiency.
As the owner of a new pellet stove, you’ll want to read and 

carefully follow all of the instructions contained in this owner’s 

manual. Pay special attention to all cautions and warnings.

This owner’s manual

 

should be retained for future reference. 

We suggest that you keep it with your other important 

documents and product manuals.
Your new Harman

®

 Absolute43-C Freestanding Pellet Stove 

will give you years of durable use and trouble-free enjoyment. 

Welcome to the Harman

®

 family!

Harman

®

 is a registered trademark of Hearth & Home 

Technologies.

Note: Cast iron is an artisan crafted material, which is 

made the same way today as nearly 2000 years ago. 

Due to the intrinsic primitive nature of the casting 

process, part to part variation is normal and adds to the 

character of a hand built cast iron appliance

Read this manual before operating this appliance. 

Please retain this Owner’s Manual for future reference.

Read the Installation Manual before making any installation or finishing changes.

Listing Label Information/Location

The model information regarding your specific stove can be found on the 

rating plate usually located in the control area of the stove.

BARCODE LABEL

HF

Serial No.

N

o

 de série:

MODEL / MODÈLE: “Absolute43-C”

Room Heater Pellet Fuel-Burning Type

SUITABLE FOR MOBILE-HOME INSTALLATION

This pellet burning appliance has been tested and listed for use In

Manufactured Homes In accordance with OAR 814-23-900 through 814-23-909

352 Mountain House Road, Halifax, PA 17032    (É.-U.)

THIS AREA MUST 

BE BLACK

MINIMUM CLEARANCES TO

COMBUSTIBLES

Back Wall to Appliance 

2”

Side Wall to Appliance 

6"

Corner Installation

Walls to Appliance 

6.25”

Use  a  non-combustible  floor  protector 

extending under and to the sides, front 

and  back  of  the  unit  as  shown  in  floor 

protection diagram. Measure front 

distance from the surface of the glass 

door.

Recommended: Non-combustible floor 

protection  extended  beneath  the  flue 

pipe when installed with horizontal 

venting.
Floor Protection*

 

USA 

CANADA

Sides  (A)  6” 

152 mm

Back  (B)  1” 

25 mm

Front  (C)  6” 

152 mm

Alcove Installation

Min. Alcove Height  42” (1067mm)

Max. Alcove Depth  24” (610mm)

Report / Rapport

 #0135PS039E, 0135PS032S

Test to/testé à ASTM E 1509-12, ULC-S627-00, 

ASTM E 2515-11, ASTM E 2779-10

Room Heater, Pellet Fuel-Burning Type, Also For 

Use In Mobile Homes. (UM) 84-HUD

“PREVENT HOUSE FIRES”

 Install and use only 

in accordance with manufactures installation and 

operation instructions.

Contact  local  building  or  fire  officials  about 

restrictions and installation inspection in your area.

WARNING: FOR MANUFACTURED HOMES:

 

Do not install appliance in a sleeping room. An 

outside combustion air inlet must be provided. The 

structural integrity of the manufactured home floor, 

ceiling and walls must be maintained.

Refer to manufacturer’s instructions and local 

codes for precautions required for passing chimney 

through a combustible wall or ceiling. Inspect 

and clean exhaust venting system frequently in 

accordance with manufacturer’s instructions.

Use a 3” or 4” diameter type “L” or “PL” venting 

system.

Do not connect this unit to a chimney flue servicing 

another appliance.

Do not obstruct the space beneath the heater.

FOR USE WITH PELLETIZED WOOD FUEL ONLY.

EPA Certified Emissions: .99 g/hr

Input Rating Max:

 5.0 lb. fuel/hr

Electrical Rating:

 240 VAC, 50 Hz, Start 1.75 

AMPS, Run 1.25 AMPS

U.S. Electrical Rating:

 115 VAC, 60 Hz, Start 3.5 

AMPS, Run 2.5 AMPS

Fuel Type: 

Wood Pellet ONLY

Route power cord away from unit.

Modèle: “Absolute43-C”

Appareil de chauffage à granulés de bois

CONÇU POUR MAISONS MOBILES

3-90-7772_R1

OPERATE ONLY WITH DOORS CLOSED
DANGER

: Risk of electrical shock. Disconnect power supply before servicing.

Replace glass only with 5mm ceramic available from your dealer.
For further instruction refer to owner’s manual.
Keep viewing and ash removal doors tightly closed during operation.

DANGER:

 Risque d’électrocution. Coupez l’alimentation 

électrique avant l’entretien. 

Remplacer le verre avec 5 mm miroir verre céramique de la 

même qualité disponible auprès de votre revendeur. 

En tenant la porte d’entrée et le couvercle de la trémie 

hermétiquement fermé pendant le fonctionnement de 

l’appareil

DISTANCES DE SECURITE PAR RAPPORT AUX 

MATERIAUX COMBUSTIBLES

Paroi arrière à l’appareil 

51 mm

paroi latérale de l’appareil 

152 mm

Installation en angle

Entre murs et apparell 

159 mm

I

nstallation en alcôve

Hauter minimale de l’alcôve 

1067 mm

Profondeur maximale de l’alcôve  610 mm

PROTECTION DU SOL*

Côtés  (A)  152 mm

Arrière (B)  25 mm

Avant  (C)  152 mm
Utiliser une protection de sol non combustible sous l’appereil 

qui s’étend sur les côtes, l’avant et l’arrière du poêle (voir 

schéma). Pour la distance à l’avant, mesurer à partir de la 

surface de la porte en verre.
ll est recommendé que la protection s’étende jusque sous le 

conduit en cas d’installation d’un conduit horizontal ou sous 

le té en cas conduit vertical.

Do not remove this label/Ne pas enlever cette étiquette.

Made in the USA/Fabriqué aux É.-U.

Test pour / tested à la norme ASTM E 1509-12, ULC-S627-00, 

ASTM E 2515-11, ASTM E 2779-10

Chauffe-chambre, Pellet à combustibles Type, également pour les 

maisons mobiles. (UM) 84-HUD

"Empêcher MAISON incendies"

 Installer et utiliser uniquement 

en conformité avec les instructions du fabricant d'installation et 

d'exploitation.

Contactez le service des incendies à propos des restrictions et 

l'inspection d'installation dans votre région.

A

VERTISSEMENT: POUR maisons préfabriquées:

 Ne pas 

installer l'appareil dans une chambre à coucher. Une entrée d'air 

de combustion à l'extérieur doit être fournie. L'intégrité structurale 

de la maison étage, plafond et murs fabriqués doit être maintenue.

Reportez-vous aux instructions du fabricant et les codes locaux 

pour les précautions nécessaires pour faire passer la cheminée à 

travers un mur ou un plafond combustible. Inspectez et nettoyez 

système d'évacuation souvent en conformité avec les instructions 

du fabricant.

Utilisez un "ou 4" Type de diamètre «L» 3 ou le système de 

ventilation "PL".

Ne pas connecter cet appareil à un conduit de cheminée 

desservant un autre appareil.

Ne pas obstruer l'espace sous le chauffe-eau.

À UTILISER AVEC LA GRANULE DE BOIS SEULEMENT.

Émissions certifiés EPA: ,99 g / h

Entrée Max Note:

 £ 5,0 carburant / h

Note électrique:

 240 VAC, 50 Hz, Lancer 1,75 AMPS, Exécuter 

1,25 AMPS

US Note électrique:

 115 VAC, 60 Hz, 3,5 AMPS Démarrer, 

Exécuter 2,5 AMPS

Type de carburant: Bois Pellet SEULEMENT

Route cordon électrique de l'appareil.

Fonctionner uniquement avec les portes fermées

Ce poêle à bois a besoin d’une inspection et d’une réparation 

périodiques pour fonctionner correctement. Consultez le manuel 

du propriétaire pour plus d’informations. Il est contraire à la 

réglementation fédérale d’utiliser ce poêle à bois d’une manière 

non conforme aux instructions d’utilisation du manuel du 

propriétaire.

Date of Manufacture / Date de fabrication:

2018   2019   2020   JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032

LABEL TICKET

ECO:

87270

LABEL SIZE:

5.75” H x 13.562” W

PART # / REV:

3-90-7772_R1

ADHESIVE:

ORIGINATOR:

Spidlet

MATERIAL:

24 Gauge Aluminum

DATE:

06/05/18

INK:

Black Background

(1) Holes = Ø.30

(5) Slotted Holes = .156 x .25

(4) Corners = R.062

Barcode label must have the serial number on it.

The barcode label must be able to read Code 39 Full ASCII.

352 Mountain House Road

Halifax, PA 17032

6"

2"

6.25"

6.25"

A

C

B

US ENVIRONMENTAL PROTECTION AGENCY

The  Absolute43-C is Certified to comply with 2020 particulate 

emission standards. 

L’Absolute43-C est certifié conforme aux normes d’émission de 

particules de 2020.

This wood heater needs periodic inspection and repair for proper operation. 

Consult the owner’s manual for further information. It is against federal regulations 

to operate this wood heater in a manner inconsistent with the operating instructions 

in the owner’s manual.

Model Name

Serial Number

EXAMPLE

Summary of Contents for HARMAN Absolute43-C

Page 1: ...wn WARNING Please read this entire manual before installation and use of this pellet fuel burning room heater Failure to follow these instructions could result in property damage bodily injury or even death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not overfire If any external part starts to glow you are overfiring Reduce f...

Page 2: ...to owner s manual Keep viewing and ash removal doors tightly closed during operation DANGER Risque d électrocution Coupez l alimentation électrique avant l entretien Remplacer le verre avec 5 mm miroir verre céramique de la même qualité disponible auprès de votre revendeur En tenant la porte d entrée et le couvercle de la trémie hermétiquement fermé pendant le fonctionnement de l appareil DISTANCE...

Page 3: ...time Warranty 21 C Loss of Power 23 D Emergency Manual Ignition 23 E Troubleshooting 24 F Contact Information 26 1 Product Specifications and Important Safety Information A Appliance Certification 4 B Glass Specifications 4 C Mobile Home Approvals 4 D BTU Specifications 4 E Electrical Codes 4 2 Important Safety and Operating Information A Appliance Safety 5 B Clear Space 6 C California Safety Info...

Page 4: ...ions in this manual This wood heater needs periodic inspection and repair for proper operation It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual E Electrical Codes 120 VAC 60 Hz Start 4 0 Amps Run 3 0 Amps Notice This appliance must be electrically wired and grounded in accordance with local codes or in the absence of ...

Page 5: ...perative that control compartments and circulating air passageways of this stove be kept clean A Appliance Safety WARNING THIS WOOD HEATER HASAMANUFACTURER SET MINIMUM LOW BURN RATE THAT MUST NOT BE ALTERED ITISAGAINSTFEDERALREGULATIONS TOALTERTHISSETTINGOROTHERWISEOPERATE THISWOODHEATERINAMANNERINCONSISTENT WITHOPERATINGINSTRUCTIONSINTHISMANUAL 2 2 Important Safety and Operating Information Check...

Page 6: ...ed periodically throughout the heating season to determine if creosote buildup has occurred If a significant layer of creosote has accumulated 1 8 or more it should be removed to reduce the risk of a chimney fire If a fire occurs call the fire department shut down the stove and evacuate the residence Before using the appliance have the venting system thoroughly inspected and replace any damaged co...

Page 7: ...ture will rob BTU s and may not burn properly Fuel should not be stored within the stove installation clearances or within the space required for cleaning and ash removal Fuel and Fuel Storage Pellet fuel quality can fluctuate from manufacturer to manufacturer and even from bag to bag Fuel Material Made from sawdust and or other wood by products Source material typically determines ash content Hig...

Page 8: ...Fill hopper with pellets Initial start up Only 1 Select Language 3 Adjust arrows to set room desired temperature 4 Touch the On Off Power Icon Refer to Touch Manual for all other operations Please Note The USB port on the EASY Touch Control is not a charging port for smartphones tablets etc ...

Page 9: ...gency heating needs G Frequently Asked Questions With proper installation operation and maintenance your appliance will provide years of trouble free service If you do experience a problem this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken Contact your dealer for additional information regarding operation and troubl...

Page 10: ...per If you did not fill hopper The message will disappear in 30 seconds Replace the 2 AA batteries in the Wireless Remote Sensor If Wireless Remote Sensor batteries die the Back Up Sensor will continue to heat your home Check and close the front and ash doors for the stove to continue to heat Close the hopper lid for the stove to continue to heat Fill the hopper with pellets Press check mark to re...

Page 11: ...TE THE STOVE MUSTBE COMPLETELYOUTBEFORE YOU VACUUM THE STOVE LIVE PELLET EMBERS IF SUCKED INTO THE VACUUM WILL LIGHT THE VACUUM ON FIRE AND MAY ULTIMATELY CAUSE A HOUSE FIRE Follow the detailed instructions found in this section for each step listed in the chart below Shock and Smoke Hazard Turn unit to the off position let appliance completely cool and combustion fan must be off Now you can unplu...

Page 12: ...t ashes into a steel non combustible container with tight fitting lid outside Use provided paint brush Vacuum loose ash from around igniter and inside burn pot Stove MUST be turned off cold and unplugged from power supply for Yearly Cleaning Yearly4 Brush vacuum the combustion fan and venting exhaust path Wear protective gloves 1 Put ashes into a steel non combustible container with tight fitting ...

Page 13: ...anger Cleaning the Heat Exchanger Clean the heat exchanger with scraper as shown in Figure 2 2 Brush or scrape the inside of the stove to remove fly ash Remove the ash pan and dispose of ashes in an approved manner according to local codes Figure 2 2 Scrape these areas free of flyash or carbon buildup Cleaning the Burn Pot Vigorously scrape the top holed surface and sides of the burn pot down to a...

Page 14: ...he bolts Cleaning Igniter Bracket Check cleanliness of the igniter and inner burnpot If the igniter has ash buildup it must be removed to insure proper ignition Use the provided brush to remove ash buildup from in and around the igniter Once ash is loose vacuum around igniter and at the base of burn pot Yearly Maintenance Cleaning the Combustion Fan Chamber The combustion inlet cover is located be...

Page 15: ...bstances Wash the surface with cool water and rinse thoroughly You may wish to use a non abrasive cleaner specifically designed for use on stove glass In any case dry thoroughly before relighting your stove Inspect all Gaskets While the unit is cool inspect all door gaskets to insure proper seal The gasket should be continuous without frays or tears having plyable gasket means having a correct sea...

Page 16: ...let Stove 05 20 1 90 777100 1 Black Beginning Manufacturing Date July 2018 Ending Manufacturing Date Feb 2020 1 90 777100 14 Majolica Brown Beginning Manufacturing Date July 2018 Ending Manufacturing Date Feb 2020 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 1 90 777101 1 Black w Wireless Beginning Manufacturing Date Feb 2020 1 90 777101 14 Majolica Brown w W...

Page 17: ...g of 100 3 31 94807 100 5 Hopper Lid Hinge w Hardware 1 00 777147 Y Hopper Lid Hinge Pin Plates w Hardware 1 Set 1 00 777560 6 Cast Top Black 4 00 247236S Majolica Brown 1 00 247236 14 7 Hopper Assembly 1 10 777130A Y Gasket Hopper Throat 3 44 677185 Y Gasket 3 8 X 1 2 20 Feet 1 00 375501 Y Gasket 5 8 X 1 2 20 Feet 1 00 625501 Y 8 Left Side Cast Black 4 00 777645P Majolica Brown 1 00 777645 14 9 C...

Page 18: ...0 777149 Y Rollers Hardware 1 Set 1 00 77723 Y 16 Ash Pan 1 10 777121A Y 17 Burn Pot Assembly 17 1 Burn Pot Weldment 1 10 777901A Y Gasket Burn Pot 3 44 237639 Y Flame Guide 3 00 03000 Y 17 2 Ingiter 3 20 677200 Y Pkg of 10 1 00 677200 Y 17 3 Igniter Bracket 1 00 777906 17 4 Burn Pot Clean Out w Hardware 1 00 777908 Y 1 4 20x1 2 Pkg of 50 3 30 2001 50 Y 18 Leg Leveling Kit 1 Set 1 00 12302 19 Leg ...

Page 19: ... 2 req SRV3 21 07775 Y 28 Rear Cover Right 1 00 777124 Y 29 Differential Switch 3 20 6866 Y Tubing 1 8 Silicone 5 Feet 1 00 5113574 Y 30 Rear Cover Left 1 00 777123 Y 31 Feeder Assembly 31 1 Feeder Body 1 10 777513A Y 31 2 Slide Plate Assembly 1 10 777690A Y 31 3 Feed Cover Gasket 2 Sets 1 00 677122 Y 31 4 Pusher Arm 1 10 677187W Y Pillow Block Pkg of 4 3 31 3614087 4 Y 31 5 Auger 3 50 00565 Y 31 ...

Page 20: ...hen requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 5A Ceramic Fuse Pkg of 5 1 00 05237 Y Communication Cable 3 20 72662 Y Draft Meter Assembly 1 00 00637 Draft Meter Bolt Tube 1 00 04004 External Temp Extension 3 20 70607 Y Flue Tube Cleaning Brush 3 40 00126 Heat Shield 1 00 777112 Y Inlet Cover 1 00 777607 Control Board 1 00 05372 ...

Page 21: ...ier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for covered components is produced in the following table The term Limited Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances and 10 ye...

Page 22: ...per handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental conditions inadequate ventilation negative pressure or drafting caused by tightly sealed constructions insufficient make up air supply or handling devices such as exhaust fans or forced air furnaces or other such causes 6...

Page 23: ...e the fire is out the ESP temperature will not rise The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume normal operation Contact your dealer if you have questions about UPS compatibility with your appliance Use only Harman approved battery back up devices Other products may not operate properly can create unsafe condit...

Page 24: ...r has failed Partially burned pellets Feed rate too high Poor air to fuel mixture Check burn pot clean out cover and air intake Burn pot may need to be cleaned Combination of all the above Smoke smell Seal the vent pipe joints and connection to stove with silicone The exhaust vent is the only part of the system that is under positive pressure Fire has gone out No fuel in hopper Draft is too low bl...

Page 25: ...Harman Absolute43 C Owner s Manual_R8 2018 ___ 05 20 25 3 90 00772C ...

Page 26: ..._____ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ______________________________________________________________________...