51
Hearth & Home Technologies • B41L-AU Installation Manual • 2570-980 Rev. C • 7/20
D. Decorative Barrier Front Finishing
WARNING! Risk of Fire!
A decorative front is required
for this model. DO NOT operate this appliance without a
decorative front in place.
Overlap Fit
(0 - 1 in. max. (0 - 25 mm max.)
Thick Finishing Material)
Figure 10.10 Overlap Fit Method (CFTF Decorative Barrier
Front)
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD
NON-COMBUSTIBLE
FINISHING MATERIAL 0 - 1
IN (0 - 25 mm). THICK
NON-COMBUSTIBLE
FINISHING MATERIAL 0 -
1 IN. (0 - 25 mm) THICK
CFTF
DECORATIVE BARRIER
FRONT SHOWN
DRYWALL OR EQUIVALENT
(10 mm)
Non-Combustible Finish Materials
0 - 1 in. (0 - 25 mm) Thick
Overlap Fit Method
The CFTF is designed to overlap finish materials 0 in.
to
1 in (0 - 25 mm) thick. See Figure 10.10.
NOTICE:
This one inch maximum not only includes the
decorative finish materials (marble, tile, slate, etc) but
also the mortar or adhesive used to attach the decorative
finish material
.
The non-combustible finish material can be installed up to
the fireplace opening.
FRONT FACE OF FIREPLACE
DECORATIVE BARRIER FRONT
1 IN. (25 mm) MAX.
FINISHING MATERIAL
(TOP EDGE)
Figure 10.9 Overlap Fit Decorative Front
(CFTF Decorative Front)
Finishing materials 1 in. (25 mm) maximum thick.
Stop finishing material flush with opening.
Only decorative barrier fronts certified for use with this ap
-
pliance model may be used. Contact your dealer for a list
of decorative barrier fronts that may be used.
THE GUARD IS FITTED TO THIS APPLIANCE
TO REDUCE THE RISK OF FIRE OR INJURY
FROM BURNS AND NO PART OF IT SHOULD
PERMANENTLY BE REMOVED. FOR PROTEC-
TION OF YOUNG CHILDREN OR THE INFIRM.
A SECONDARY GUARD IS REQUIRED.