background image

Hearth & Home Technologies Inc. • ST1175 Termination Cap • 34502 Rev E • 01/05

1

��

Models:

ST1175

Termination Cap

Installation

 Instructions

These chimney termination caps have been tested for use with specific Hearth & Home Technologies Inc. (HHT) fireplaces 

and is a fireplace part. Refer to the fireplace installation isntructions for the correct accessories to be used. Check with 

your local building code agency before you begin installation to ensure compliance with local codes, including the need 

for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need clarification 

of any of the instructions contained here, contact the Heatilator Technical Services Dept., Hearth & Home Technologies 

Inc., 1-800-927-6841 or 1-888-427-3973.

Note: 

An arrow (

) found in the text signifies change in 

content.

1a

3

2

1b

FEET

CHASE TOP

MAX. 4-3/4 in.

(121 mm)

Item

Description

Qty

1a

Termination Cap - Top

1

1b

Termination Cap - Base

1

2

Slip Section

1

3

Fastener Package

1

Note: 

The ST1175 is designed for use 

with the SL1100 Series pipe.

Sharp Edges

•  Wear protective gloves and safety 

glasses during installation.

CAUTION

1. 

Assemble the SL1100 Series chimney Sections to within 4-3/4 in. 

(121 mm) below the top of the chase.

2. 

Remove the top by taking out the four screws that secure it to the 

corner posts.  If the top is not screwed on, proceed to Step 3.

3. 

Center the partially disassembled base of the termination cap 

over the chimney (inside the chase). Drop the double walled slip 

section through the flanged opening in the base of the termina-

tion cap so it telescopes both the inner and the outer chimney 

sections.

4. 

Adjust the termination cap so the slip section does not bind the 

chimney section. Rotate the cap so it is square with the chase 

and mark the position using the holes provided in the feet as a 

guide.

5. 

Drill through the chase top using a 1/8 in. (3 mm) diameter drill 

bit at the marked locations. Securely attach the cap to the chase 

using the screws provided in the fastener package.

6. 

Assemble the top of the termination cap and replace and tighten 

all the screws.

7. 

Caulk all screws or nails on the chase top. Periodic re-caulking 

may be needed to prevent leaks from developing.

Fire Risk

You must use the slip section provided with 

this chimney top.

•  Single wall or other variations from the 

slip section MUST NOT be used.

Substitute parts may increase temperatures 

to adjacent combustible materials.

WARNING

Fire Risk

•  Intended  for  use  with  a  metal  chase 

top.

Use  of  combustible  materials  will  cause  a 

fire hazard.

WARNING

Reviews: