TRANSMITTER SAFETY FEATURES

It is recommended that the TRANSMITTERS always be 
located within a 20 foot operating range of the 

fi

 replace, 

preferably in the same room in which the 

fi

 replace system 

is located. The TRANSMITTER features several safety 
features that alert the user when the TRANSMITTER is 
placed outside the 20 foot normal operating range.

Communication-Safety Features

This remote control has a COMMUNICATION-SAFETY 
function built into its software. It provides an extra margin 
of safety when the TRANSMITTER is out of the normal 
20 foot operating range of the receiver. It is also activated 
when the batteries become weak or are removed from the 
transmitter.
In the THERMO-UPDATING feature (only in the THERMO 
or TIMER modes) the transmitter normally reads the ROOM 
temperature every 2 minutes. In addition to checking the 
temperature, the transmitter sends a signal to the receiver in-
dicating that the transmitter and its batteries are still active. 
In the COMMUNICATION-SAFETY feature, at all times 
and in all OPERATING MODES the transmitter sends a 
signal every 

fi

 fteen (15) minutes to the receiver, indicating 

that the transmitter is within the normal operating range 
of 20 feet. 
Should the receiver NOT receive a transmitter signal every  
15 minutes (COMMUNICATION-SAFETY feature), the RE-
CEIVER will begin a 2 HOUR (120 minute) countdown tim-
ing function. If during this 2 hour period, the receiver does 
not receive a signal from the transmitter, the RECEIVER 
will shut down the 

fi

 replace being controlled by the receiver. 

The RECEIVER will then emit a series of rapid “beeps”. 
Then, after 10 rapid “beeps”, the RECEIVER will continue 
to emit a single “beep” every 4 seconds until a transmitter 
signal is again received. The intermittent 4 seconds beep-
ing will go on inde

fi

 nitely until reset.

To “reset” the RECEIVER and operate the 

fi

 replace system:

1.  Press the MODE  button on  the transmitter. The word 

ON must display on the LCD screen. The COMMUNICA-
TION -SAFETY operation is overridden and the system 
will return to normal operation depending on the MODE 
selected at the transmitter. 

We recommend the user check the batteries in the 
TRANSMITTER to make sure the voltage is no less than 
2.7 volts.

Auto Shutdown

This remote control has an Auto Shutdown feature incor-
porated into its system. When the transmitter MODE is 
in the ON position the 

fi

 replace will continuously operate 

for 9 hours. After 9 hours, the 

fi

 replace will shut down. To 

relight the 

fi

 replace:

1.  Press the MODE button. 
The Auto Shutdown signal comes from the transmitter. The 
transmitter must be positioned within a 20 foot operating 
range for the Auto Shutdown feature to operate.

SYSTEM CHECK

Standing Pilot Valves

Light the appliance following the lighting instructions that 
came with the 

fi

 replace. Con

fi

 rm that the pilot 

fl

 ame is on. 

It must be in operation for the main gas valve to operate.
1.  Slide the 3-position button on the remote receiver to the 

ON position. The main gas 

fl

 ame (i.e., the 

fi

 re) should 

ignite.

2.  Slide the button to OFF. The 

fl

 ame should extinguish 

(the pilot 

fl

 ame will remain on).

3.  Slide the button to REMOTE (the center position), then 

press the MODE button on the transmitter to change 
the system to ON. The main gas 

fl

 ame should ignite.

4.  Press the MODE button on the transmitter to change 

the system to OFF. The 

fl

 ame should extinguish (the 

pilot 

fl

 ame will remain on).

5.  Press the MODE button on the transmitter to change 

the system to THERMO. 

6.  Advance the SET temperature on the transmitter to a 

temperature of at least 2

º

 

F (1

º

 

C) above the ROOM 

temperature displayed on the LCD screen and the 
system 

fl

 ame will ignite.

7.  Set the SET temperature to at least 2

º

 

F (1

º

 

C) below 

the room temperature and the system 

fl

 ame will extin-

guish. Thereafter, it should continue to cycle on and 
off thermostatically approximately every two minutes 
as the ROOM temperature changes, but only when 
the temperature differential between ROOM and SET 
temperatures differs at least 2

º

 

F (1

º

 

C). The 2

º

 

F (1

º

 

C)

 

F differential is the factory setting.

Child Proof Lockout (CP)

The transmitter contains a “Child Proof” lockout feature 
that prevents unauthorized use of the remote control. To 
access the “Child Proof” activation button, remove cover 
on BACK of transmitter. To activate LOCKOUT:
1.  Press and hold in the “setting button” for 5 seconds. The 

letters CP will display on the LCD screen (see Figure 
6). This prevents the activation of 

fi

 replace. When any 

function button is pressed ON/OFF etc. the letter CP 
will display on the LCD screen. 

To deactivate LOCKOUT: 
1.  Press and hold in the “setting button” for 5 seconds. The 

LCD will display CP until 5 seconds have elapsed, and 
then the LCD screen will return to its normal state.

Summary of Contents for SMART-STAT

Page 1: ...nada Operation is subject to the following two condi tions 1 this device may not cause interference and 2 this device must accept any interference including interfer ence that may cause undesired oper...

Page 2: ...to the outside of the fireplace RECEIVER WIRING INSTRUCTIONS Incorrect wiring connections WILL cause damage to the gas valve or electronic module operating the gas appliance and may also damage the r...

Page 3: ...for longer battery life and maximum operational performance Insert 2 AAA size 1 5V batteries into the battery compart ment on the back of the transmitter When the batteries are correctly inserted the...

Page 4: ...ould be heard If no beeping is heard check to see that the receiver has 110 120VAC power to it If you are unsuccessful in matching the security code on the first attempt wait 1 2 minutes before trying...

Page 5: ...emperature is 45 F 7 C NOTE To prevent repeated thermo cycling of the gas appliance the sensing unit in the transmitter will only ac tivate the remote receiver when the temperature change exceeds 1 F...

Page 6: ...volts Auto Shutdown This remote control has an Auto Shutdown feature incor porated into its system When the transmitter MODE is in the ON position the fireplace will continuously operate for 9 hours...