Hearth and Home Technologies RCT-MLT-IV Installation And Operating Instructions Manual Download Page 9

DRAFT

This is a DRAFT copy and is subject to change.  It is not approved for release.  DO NOT COPY!

9

Hearth & Home Technologies  •  RCT-MLT-IV Remote Control Instructions  •  100-908 Rev. D  •  12/19

Figure 9.  Intermittent Pilot Ignition (IPI) Wiring Diagram

Figure 10.  Standing Pilot Ignition Wiring Diagram

TRANSFORMER

3 VAC

PLUG IN

RED

BATTERY PACK

THERMOSTAT

WIRE ASSEMBLY

JUMPER WIRE

(TO BROWN)

(WHEN APPLICABLE)

O

R

AN

G

E

G

R

EE

N

VALVE

GROUND TO

FIREPLACE

CHASSIS

WHITE

ORANGE

IGNITION MODULE 3 VAC

INTERMITTENT PILOT IGNITOR

H

O

T

N

EU

TR

A

L

I

S

THERMOSTAT

WIRE ASSEMBLY

PIEZO

W

H

IT

E

RED

VALVE

PILOT

THERMOCOUPLE

Summary of Contents for RCT-MLT-IV

Page 1: ...an radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user i...

Page 2: ...LLED 2 Feed the electrical service wires through the Romex clamp and secure the wires to the clamp 3 Using the wire nuts provided connect the service wires to the junction box The black wires to the black service wire the white wires to the white service wire and the service ground wire to the ground stud of the junction box 4 Re attach the cover plate to the outside of the fireplace NOTE Some app...

Page 3: ...d hole in the variable regulator Turn one to two turns only Do not tighten or damage may occur Wiring the Flame Controller 1 Connect the two leads from the flame control solenoid to the orange leads from the receiver see Figure 5 2 Install a manometer into the pressure tap NOTE All steps required for installation of the flame controller MUST be done by a qualified gas service technician NOTE A man...

Page 4: ... batteries are correctly inserted the screen will display numbers see Figure 7 for LCD Display Screen NOTE If the transmitter is activated from a very cold condi tion it may be necessary to allow the transmitter to stabilize to room temperature could take up to 15 minutes before accurate room temperatures are displayed on the screen NOTE LCD screen is equipped with a backlite for easier viewing of...

Page 5: ...ner valve operational 6 CLOCK Indicates the current time in AM PM 7 ROOM Indicates CURRENT room temperature 8 ºF Indicates degrees Fahrenheit ºC indicates degrees Celsius 9 FAN Indicates fan is on or programmed to come on Three speed settings are available Transmitter Settings Flip open the plastic cover on the front of the transmitter to expose the SET buttons NOTE Flashing numbers on the display...

Page 6: ...ature When the transmitter is in the THERMO mode it should be kept away from direct sources of heat such as fireplaces incandescent lighting and direct sunlight Leaving the trans mitter in direct sunlight for example will cause it to read the room temperature higher than it actually is Setting the Countdown Timer This remote control system can operate with a built in countdown timer when the trans...

Page 7: ...RATING MODES the transmitter sends a signal every fifteen 15 minutes to the receiver indicating that the transmitter is within the normal operating range of 20 feet Should the receiver NOT receive a transmitter signal every 15 minutes COMMUNICATION SAFETY feature the RE CEIVER will begin a 2 HOUR 120 minute countdown tim ing function If during this 2 hour period the receiver does not receive a sig...

Page 8: ...n time on the LCD screen expires After 15 min elapses the system should turn off This REMOTE CONTROL SYSTEM is warranted for 12 months from the date of purchase or installation to the original purchaser to be free from defects in materials and workmanship Damage to the SYSTEM caused by accident misuse abuse or installation error whether performed by a contractor service company or owner is not cov...

Page 9: ...Intermittent Pilot Ignition IPI Wiring Diagram Figure 10 Standing Pilot Ignition Wiring Diagram TRANSFORMER 3 VAC PLUG IN RED BATTERY PACK THERMOSTAT WIRE ASSEMBLY JUMPER WIRE TO BROWN WHEN APPLICABLE ORANGE GREEN VALVE GROUND TO FIREPLACE CHASSIS WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR HOT NEUTRAL I S THERMOSTAT WIRE ASSEMBLY PIEZO WHITE RED VALVE PILOT THERMOCOUPLE ...

Page 10: ...trol Intermittent Pilot Ignition IPI Wiring Diagram GREEN ORANGE JUMPER WIRE TO BROWN WHEN APPLICABLE PLUG IN TRANSFORMER 3 VAC BLACK RED GROUND TO FIREPLACE CHASSIS WHITE ORANGE INTERMITTENT PILOT IGNITOR IGNITION MODULE 3 VAC REMOTE RECEIVER BATTERY PACK I S JUMPER WIRE SUPPLIED WITH RCT MLT IV ADAPTER WIRES FLAME SOLENOID IPI VALVE RED RED Receptacle on back Line cord from fan RED ORANGE RED OR...

Page 11: ...th Home Technologies dealer with any questions or concerns For the location of your nearest Hearth Home Technologies dealer please visit www hearthnhome com Hearth Home Technologies 7571 215th Street West Lakeville MN 55044 www hearthnhome com Figure 12 Remote Control Standing Pilot Ignition Wiring Diagram PIEZO WHITE RED PILOT THERMOCOUPLE VALVE JUMPER WIRE SUPPLIED WITH RCT MLT IV RED ORANGE RED...