25
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
Installation Steps:
If the appliance is equipped with an IFT-ACM, proceed to
step 10. If not, proceed to next step.
5. Locate the IntelliFire™ Touch electronic control module
(IFT-ECM) in the control cavity of the appliance and
move the three-position switch to the OFF position.
See Figure 4.7.
6. Remove protective rubber cap from connector on the
top of the IFT-ECM. See Figure 4.7.
Figure 4.7. IFT-ECM
8. Connect the IFT-ACM to the IFT-ECM by aligning the
pins and tabs and pushing the IFT-ACM into the IFT-
ECM until both tabs latch in place. Ensure the IFT-
ECM and IFT-ACM are aligned with each other and
fastened securely. See Figure 4.8.
Figure 4.8. Connecting IFT-ACM and IFT-ECM
WARNING! Risk of Shock! DO NOT
touch male pins.
Leave rubber cap on all ports unless port is being con-
nected to a load.
9. The IFT-ACM can provide power to HHT approved
options including fan, lights and power vent.
•
To connect a fan kit to the IFT-ACM, insert the
three prong male plug from the fan into the re-
ceptacle located on the right side of the IFT-ACM.
See Figure 4.9.
•
To connect a light kit to the IFT-ACM, remove pro-
tective rubber cap labeled ‘LIGHTS’ and connect
to the female cord that was supplied in your lights
kit into the three male pins on the IFT-ACM. See
Figure 4.9.
•
To connect a power vent kit to the IFT-ACM, re-
move protective rubber cap labeled ‘AUX’ and
connect to the female cord of the PVI-WH wire
harness into the three male pins on the IFT-ACM.
See Figure 4.9.
Figure 4.9. Fan, Lights and Power Vent Connection
WARNING! Risk of Shock! DO NOT
touch male pins.
Leave rubber cap on all ports unless port is being con-
nected to a lead.
POWER CORD
FAN
POWER
VENT
LIGHTS
10. Refer to wiring diagram with Power Vent to make re-
maining connections. See Figure 4.10.
7. Attach velcro included with the IFT-ACM to the bottom
of the ACM. See Figure 4.8.
ATTACH VELCRO
Note:
It will be necessary to re-pair the remote
after installing HHT approved options to the appliance.
Refer to Section 4C for pairing the remote.