Hearth and Home Technologies Heat-Zone-240V Air Duct Kit Installation And Operation Instructions Download Page 2

Hearth & Home Technologies  •  Heat-Zone-240V Air Duct Kit  •  299-900D  •  7/10

2

FLOOR REGISTER

TWO DUCT KITS

WALL REGISTER

WALL REGISTER

WALL REGISTER

CEILING REGISTER

Figure 2

Possible Air Duct Runs/Locations

2.  The Heat-Zone 240V kit is tested and safe when installed 

in accordance with this installation manual. This kit is 
carefully engineered and must be installed only as speci-
fi ed. Modifying the kit or any of its components will void 
the warranty, and may possibly cause a fi re hazard.

3.

 CAUTION: 

Installation of this appliance should only be 

carried out by an authorized person. All relevant codes 
and regulations laid down by the gas piping authorities, 
municipal building regulations, electrical wiring regula-
tions and the requirements of the AS5601 Gas Instal-
lation code must be observed.

4.  Plan the location of the heater and the warm air duct 

run(s).

MAXIMUM

 Duct Run = 

6 M for useful heat output.  

MINIMUM 

Duct Run =  

NA - for runs out from the heater 

to adjacent room OR down to the room below.

MINIMUM 

Duct Run 

= 787 mm top of heater to room 

above.

COVER

PLATE

DUCT

COLLAR

6000 SERIES

XLR-AU

Installation

1.  Remove the cover plate from the side of the heater and 

discard it.

2.  Center the duct collar around the exposed hole and 

attach it to the heater with 3 screws.

 NOTE:

 Do this 

BEFORE 

fi nal positioning of the heater. See Figure 3.

Figure 3

Summary of Contents for Heat-Zone-240V Air Duct Kit

Page 1: ...rs Introduction The HEAT ZONE 240V accessory kit conveys warm air from the heater through air duct s to remote locations in the same room or other rooms of the building See Figures 1 and 2 One or two HEAT ZONE 240V kits can be installed on the heater Preliminary Preparation 1 Contents of kit 6 meters of 152 mm round duct Fan housing assembly Junction box Air register Register adapter frame Heater ...

Page 2: ...person All relevant codes and regulations laid down by the gas piping authorities municipal building regulations electrical wiring regula tions and the requirements of the AS5601 Gas Instal lation code must be observed 4 Plan the location of the heater and the warm air duct run s MAXIMUM Duct Run 6 M for useful heat output MINIMUM Duct Run NA for runs out from the heater to adjacent room OR down t...

Page 3: ...52 mm oval duct to the adapter Complete the duct run and attach the oval duct to the fan housing NOTE 152 mm metal oval air duct is NOT provided with this kit but can be purchased from a heating or air conditioning ventilation supplier ROUND and OVAL DUCT Acombination of 152 mm round and 152 mm oval air duct can be used in the duct run Oval duct components must be purchased from a heating or air c...

Page 4: ...ckage 3 Reference IPI Plus instructions with remote control for fan auxiliary control STUD BROWN HOT BROWN BLUE NEUTRAL BLUE YELLOW GREEN GROUND GROUND SWITCH JUNCTION BOX FAN JUNCTION BOX FAN BLUE BROWN AUX1 3 FAN SPEEDS AUX2 ON OFF CONTROL HIGH ONLY GREEN YELLOW BROWN BLUE GREEN YELLOW BLUE WHITE FAN BROWN BLACK AUX1 AUX2 FAN JUNCTION BOX 2166 191 JUMPER APPLIANCE JUNCTION BOX BLUE BROWN GREEN Y...

Reviews: