Hearth and Home Technologies GO24-IPI-LP Installation Instructions Manual Download Page 9

Hearth & Home Technologies • Grand Oak Gas Log Sets • 4004-299 Rev H • 05/08

9

L. Inspect the Venting System

The fireplace venting system is designed and constructed to 

develop a positive flow adequate to remove flue gases to the 

outside atmosphere. See fireplace installation instructions.

Possible cures if spilling occurs:

•  The damper needs to be opened further.

•  The fireplace opening needs to be reduced by adding a 

drop panel across the top under the lintel.

•  The air supply from outdoors needs to be increased. Open 

the outside air kit if the appliance is so equipped, or crack 

open a door or window.

•  If  necessary,  seek  expert  advice.  Do  not  operate  this 

appliance.

Cleaning

•  Periodic examination and cleaning of the venting system 

of the fireplace should be done before initial use and at 

least annually by a qualified agency.

A spillage test must be made before the installed 

appliance is left with the consumer.

•  Close all doors and windows in the home.

•  Light the log set (see Lighting Instructions).

•  After  three  minutes,  test  with  a  smoke  match,  smoke 

candle, stick incense or cigarette  in. below the top of 

the opening (lintel) moving across the full width. If spillage 

(smoke down into the room) occurs, it will most likely be 

near the top, outside corners.

Before  cleaning  the  appliance,  be  sure  it  is  turned 

completely off. The pilot should also be turned off. The 

unit must be completely cooled.

CAUTION

•  Logs  can  get  very  hot.  Handle  only  when  they  are 

cool.

CAUTION

After burning, the logs become fragile. Take care in 

handling.

CAUTION

M. Cleaning and Maintenance Instructions

Always remember:

•  Do  not  place  any  combustible  material  near  the 

appliance.

•  Do not place any paper, trash or other material on the log 

set or in the fireplace.

•  Do  not  touch  any  part  of  the  appliance  when  it  is  in 

operation.

•  Do not operate this appliance without the fireplace screen 

closed.

Your appliance is designed to be virtually maintenance free, 

although periodic visual inspection and cleaning is required. 

Follow the instructions below for the correct procedures. An 

annual examination and cleaning the venting system by a 

qualified person is also recommended.

N. Safety  Valve  Pilot  Flame  Adjustment  In

-

structions

The  pilot  flame  adjustment  screw  is  located  on  the  front 

side of the pilot gas tubing port. Using a small straight blade 

screwdriver, turn the screw clockwise       to adjust the pilot 

flame down and counterclockwise      to adjust the flame up. 

This screw is sensitive; therefore it will not take much adjust-

ment to accomplish this flame adjustment.

PILOT

 

ON

OFF

 

Pilot

 

Thermocouple

 

Do not allow soot to build up on the logs

Your logs require little care. Keep the burner assembly, logs 

and burner area surrounding the logs clean by brushing with 

a dry paint brush at least twice a year.

•  Always  turn  off  the  gas  to  the  pilot  before  cleaning. 

For  relighting,  refer  to  Section  P  Thru  R.  Lighting 

Instructions.

•  Always keep the appliance clean and free from combustible 

materials,  gasoline  and  other  flammable  vapors  and 

liquids.

•  Never obstruct the flow of combustion and ventilation air. 

Keep the front of the appliance clear of all obstacles and 

materials.

•  Leave clearance of at least 6 in. from the front of the 

fireplace.

Summary of Contents for GO24-IPI-LP

Page 1: ... gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installa...

Page 2: ...nings This owner s manual should be retained for future reference We suggest you keep it with your other important documents and product manuals The information contained in this owner s manual unless noted otherwise applies to all models and gas control systems Your new gas log set will give you years of durable use and trouble free enjoyment Welcome to the Hearth Home Technologies family of appl...

Page 3: ...laced before operation Aqualified service technician must perform installation and repair The appliance should be inspected and cleaned annually by a qualified service technician More frequent cleaning may be required due to excessive lint dust pet hair etc It is imperative that the control compartments burners and air passageways are unobstructed during operation Review proper placement of logs r...

Page 4: ...RE pressure testing gas line at test pressures above 1 2 psig Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1 2 psig WARNING Gas Supply Pressure Minimum inlet gas supply pressure must be 7 0 in W C for natural gas or 11 in W C for LP gas for the purpose of input adjustment Maximum inlet gas pressure must not exceed 10 5 in W C for natural g...

Page 5: ...y Damper for Venting combustion Products from Decorative Appliances for Installation in Solid Fuel Burning Fireplaces Chimney Ht Feet GO 24 35 LP Gas GO 24 35 Natural Gas GO 30 40 LP Gas GO 30 40 Natural Gas 6 49 2 64 56 6 71 4 8 45 5 59 7 52 4 66 9 10 41 7 54 3 48 2 60 2 15 37 7 48 8 43 2 54 1 20 34 3 44 4 39 8 49 1 30 31 2 40 3 35 9 44 5 Height is measured from the hearth to the top of the chimn...

Page 6: ...ks During shipping and handling of this appliance the safety pilot control valve cover may not be in place Once the burner is installed in the fireplace be sure to place the cover over the valve to prevent overheating See Figure 2 IPI models include a battery box which holds 2 D size batterys The battery box should be placed in the right front corner of your fireplace and covered with the log cove...

Page 7: ... Figure 5 Sand Figure 7 Placing Rock Wool Lightly place dime size pieces of rock wool evenly on top of the sand and vermiculite to achieve a glowing ember effect See Figure 7 Inspect the pilot burner to ensure it is clear of any rock wool Remove the Platinum Bright Embers from the package For optimum performance peel each piece apart in layers and lightly place on top of the vermiculite and rock w...

Page 8: ...hat the controls and switches are unobstructed after the granules are installed DO NOT COVER THE AIR MIXER LOCATED ON THE LOWER LEFT SIDE OF THE BURNER Place logs as shown in Sections S thru Z Place accent logs around burner on floor of fireplace Pour vermiculite into each burner pan to the point where each pan is completely full Level the vermiculite from right to left to ensure an even flame pat...

Page 9: ...Take care in handling CAUTION M Cleaning and Maintenance Instructions Always remember Do not place any combustible material near the appliance Do not place any paper trash or other material on the log set or in the fireplace Do not touch any part of the appliance when it is in operation Do not operate this appliance without the fireplace screen closed Your appliance is designed to be virtually mai...

Page 10: ...by using a corrugated flex connector to hook up the gas log set We recommend the installer use the supplied aluminum connector rather than the corrugated flexible type Can I move or change the position of the logs on my gas log set Omni certified log sets should not be altered log placement must be exactly as indicated in the set s installation instructions Can I install my gas log set myself No W...

Page 11: ... control handle clockwise to the OFF position 3 Wait 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 4 Locate pilot mounted on the right side of the top burner pan 5 Turn control handle counterclockwise to the PILOT position 6 Place a lit match at the p...

Page 12: ...lified service technician to inspect the appliance and to replace any part of the control system and any part of the gas control that has been under water 1 STOP Read the safety information listed above 2 Turn gas control handle clockwise to the OFF position 3 Wait 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information ab...

Page 13: ...Hearth Home Technologies Grand Oak Gas Log Sets 4004 299 Rev H 05 08 13 R Lighting Instructions IPI Pilot Valve IPI ...

Page 14: ...H 05 08 14 SRV738 S GO24 Grand Oak Series Logs Open the log box and remove the paper packaging and logs Inspect each log for breakage that may have occurred during shipping and handling SRV736 SRV738 SRV737 SRV722 SRV723 SRV724 SRV728 SRV729 SRV749 SRV727 SRV743 ...

Page 15: ...n See page 12 Step 3 for placement of log Fire Risk Explosion Risk Personal Injury Risk Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury WARNING T GO24 Grand Oak Series Log Placement Instructions Place logs EXACTLY as the following photos depict ...

Page 16: ... 05 08 16 U GO30 Grand Oak Series Logs Open the log box and remove the paper packaging and logs Inspect each log for breakage that may have occurred during shipping and handling SRV726 SRV720 SRV721B SRV722 SRV723 SRV724 SRV728 SRV740 SRV742 SRV743 SRV721A SRV727 ...

Page 17: ... Sets 4004 299 Rev H 05 08 17 V GO30 Grand Oak Series Log Placement Instructions Place logs EXACTLY as the following photos depict Step 1 Step 2 Step 3 SRV721B SRV720 SRV721A SRV722 SRV723 SRV740 SRV743 SRV728 SRV742 SRV722 SRV724 SRV727 SRV726 ...

Page 18: ...Rev H 05 08 18 W GO35 Grand Oak Series Logs Open the log box and remove the paper packaging and logs Inspect each log for breakage that may have occurred during shipping and handling SRV708 SRV709 SRV737 SRV728 SRV716 SRV816 SRV724 SRV808 SRV707 SRV702 SRV706 ...

Page 19: ... Grand Oak Gas Log Sets 4004 299 Rev H 05 08 19 X GO35 Grand Oak Series Log Placement Instructions Place logs EXACTLY as the following photos depict SRV737 SRV708 SRV709 SRV716 SRV728 SRV816 SRV808 SRV724 SRV707 SRV706 SRV702 ...

Page 20: ... 05 08 20 Y GO40 Grand Oak Series Logs Open the log box and remove the paper packaging and logs Inspect each log for breakage that may have occurred during shipping and handling SRV728 SRV703 SRV816 SRV724 SRV808 SRV707 SRV702 SRV706 SRV721A SRV721B SRV701 SRV700 ...

Page 21: ...nd Oak Gas Log Sets 4004 299 Rev H 05 08 21 Z GO40 Grand Oak Series Log Placement Instructions Place logs EXACTLY as the following photos depict SRV721A SRV721B SRV701 SRV700 SRV703 SRV816 SRV728 SRV724 SRV808 SRV707 SRV706 SRV702 ...

Page 22: ... H 05 08 22 Replacement Parts TM Grand Oak Gas Logs Service Parts Exploded Parts Diagram Beginning Manufacturing Date N A GO Gas Logs Ending Manufacturing Date Active 7 8 9 14 15 16 10 SP Valve Assembly GO24 30 IPI Valve Assembly IPI Valve Assembly GO24 30 35 40 ...

Page 23: ...4004 299 Rev H 05 08 23 TM Exploded Parts Diagram Beginning Manufacturing Date N A GO Gas Logs Ending Manufacturing Date Active Grand Oak Gas Logs 7 9 8 10 11 12 13 Replacement Parts Con t 1 2A 30 29 Service Parts REM Valve Assembly GO24 30 35 40 28 ...

Page 24: ...dle Tube Assy 11 2110 11 2110 1 16 SP Handle Assy 14 1019 14 1019 1 17 Top Burner Orifice NG 24 30 IPI Unit Only BPO 2 26 BPO 2 26 1 17 Top Burner Orifice LP 24 30 IPI Unit Only AM 2 49 AM 2 49 1 18 Bottom Burner Orifice NG 24 30 IPI Unit Only BPO 2 50 BPO 2 50 1 18 Bottom Burner Orifice LP 24 30 IPI Unit Only AM 2 54 AM 2 54 1 19 Switch IPI Unit Only 01 1069 01 1069 1 20 Pilot NG IPI Unit Only 20...

Page 25: ...cturing Date N A GO Gas Logs Ending Manufacturing Date Active Description of Part 24 in 30 in Qty Battery Cover Log IPI units only not shown 568A 568A 1 Sand NG only 4004 108 4004 108 2 Vermiculite 4004 109 4004 109 2 Lava Rock 4004 110 4004 110 2 Rock Wool 4004 111 4004 111 2 Damper Stop Assy 14354 14354 1 Platinum Bright Embers PBE 5 PBE 5 1 ...

Page 26: ... manufactured by HHT HHT expressly excludes from this Limited Warranty any liability hereunder for defects or damage caused by the installation or use of any parts devices or components that are not manu factured by HHT 5 Labor costs to be paid by HHT pursuant to this Limited Warranty must be approved in advance of the performance of the work by HHT and must not exceed the retail price of the repl...

Page 27: ...I S C A R D TM This product may be covered by one or more of the following patents United States 4593510 4686807 4766876 4793322 4811534 5000162 5016609 5076254 5113843 5191877 5218953 5263471 5328356 5341794 5347983 5429495 5452708 5542407 5601073 5613487 5647340 5688568 5762062 5775408 5890485 5931661 5941237 5947112 5996575 6006743 6019099 6048195 6053165 6145502 6170481 6237588 6296474 6374822...

Reviews: