![Hearth and Home Technologies BE-32 Owner'S Manual Download Page 16](http://html1.mh-extra.com/html/hearth-and-home-technologies/be-32/be-32_owners-manual_2114469016.webp)
Hearth & Home Technologies • BE-32 • InD • 2099-985 Rev. C • 9/06
16
2. Top Vent - Vertical Termination
No Elbow
Figure 5.7
Figure 5.8
Two Elbows
NOTE:
If installing a vertical vent/
termination off the top of the appli-
ance, the optional vertical termina-
tion baffl e should be used.
CAP
V
1
V
2
H
1
V
1
V
1
= 41 ft. Max. (12.5 m)
V
1
H
1
Maximum
V
2
V
1
+ V
2
Min.
1 ft
305 mm
2 ft
610 mm
*
*
*
2 ft
610 mm
4 ft
1.2 m
*
*
*
3 ft
914 mm
6 ft
1.8 m
*
*
*
4 ft
1.2 m
8 ft
2.4 m
*
*
*
5 ft
1.5 m
12 ft
3.7 m
*
*
*
V
1
+ V
2
+ H
1
= 45 ft (13.7 m) Maximum
*No specifi c restrictions on this value EXCEPT
V
1
+ V
2
+ H
1
cannot exceed 45 ft (13.7 m)
Note:
Use SL Series
components only.
Note:
Use SL Series
components only.
NOTE: There MUST be a
25% reduction in total H
when using fl ex vent except
when using the simple up
and out installation (see
Figure 5.3).