59
Hearth & Home Technologies • B36S-AU Installation Manual • 2563-980 • 10/19
A. Vent Components Diagrams (
continued
)
Figure 12.6 SLP Vent Components
13 in.
(330 mm)
15 in.
(381 mm)
8-1/8 in.
(206 mm)
10-7/8 in.
276 mm
10-1/2 in.
267 mm
3°
87°
Effective Length
5-3/4 to 8-3/8 in.
146 to 213 mm
5-1/2 in.
140 mm
8-3/8 in.
213 mm
DVP-HRC-SS
DVP-HRC-ZC-SS
HORIZONTAL TERMINATION CAP
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fireplaces, a one foot minimum
vertical vent section is required before installing
first elbow.
WARNING
• When using DVP-TB1 termination cap on top vented
fireplaces, a three foot minimum vertical vent section is
required before installing first elbow.
Figure 12.5 DVP Vent Components
13 in.
(330 mm)
15 in.
(381 mm)
8-1/8 in.
(206 mm)
SLP-HRC-SS
Horizontal Termination Cap