Hear and Learn UConnect Mini Precabling / Wiring Instructions Download Page 1

www.hearandlearn.com.au

UConnect, 955, Redcat, Topcat & SoundHouse are part of the 

www.hearandlearn.com.au

 technology family.  

Offices Australia wide (03)93709355

Hole cutout size for basket  

H250 x W285 x D80mm

250mm

290mm

285mm

114mm

325mm

6

TV

RedCat

PA

See Hear and Learn 

UConnect Install Info sheet 

for cable connection  

instructions

5

4

3

1

2

8

7

UConnect and Media Connector 

mounted on classroom wall 

1000mm from the bottom  

edge to the floor 

80mm

Hole cutout size 30mm

163mm

205mm

HubCover screws to wall  

to cover 50mm hole.

8

230mm

405mm

Mount in the middle of longest wall

GPO required  

at mounting 

location of  

RedCat

Power to rear of UConnect

UConnect Mini comes premade with  

2 x dual GPO’s. These GPO’s are to be in-

stalled inside the UConnect Mini basket 

once connected to power. These GPO’s 

power the UConnect Mini itself (and its 

internal electronics), power the Media 

Connector (via cable between the UCon-

nect Mini and the Media Connector).

Feed from PA speaker in the room.

UConnect Mini needs to receive a feed 

from the PA speaker in the room. Run 

cable (supplied by others) from the rear 

of the PA speaker location to the rear of 

the UConnect Mini. Cable is connected 

to UConnect Mini using terminal built 

into the UConnect Mini.

Audio from AV device (TV/Projector)

Connection between  

UConnect Mini & Media Connector

Right angle 3.5mm plug to 3.5mm plug 

cable (supplied by Hear and Learn) 

needs to have right angle end through 

hole behind 955 and straight end to  

 rear of UConnect.

Power supply for  

Media Connector

The Media Connector receives 

power from a devoted GPO with 

USB inside the UConnect Mini. 

Holes for UConnect basket/wall plate system.

A. HOLES IN WALLBOARD

UConnect Mini/Media Connector must be installed in an unobscured location to allow line 
of sight to the UConnect. It is for everday use and accessible to teachers and students.

B. PRECABLING

285mm x 250mm hole to surround the  

basket, with bottom edge of system  

1000mm approx from the floor.

30mm hole for cables to Media  

Connector, 114mm from top of  

UConnect system to the centre  

of the hole, and in the centre. 

Where cable length from AV device 

to rear of UConnect Mini is less than 

10 metres, run a 3.5mm male cable. 

Where cable length from AV device 

to rear of UConnect Mini  is more 

than 10 metres, run CAT6 (supplied 

by others) and at each end connect 

audio extenders. Connection of 

cable to AV source to be determined 

/completed by others.

Hear and Learn UConnect Mini & Redcat/Media Connector Bundle

Precabling / Wiring Instructions

UConnect Mini is an all in one, remade hearing augmentation hub  

which comes to site at the last stage of construction. For the purpose 

of prewiring/cabling, a sample UConnect Mini will be provided.  

The basket shown is screwed to sides of vertical and horizontal studs 

with the rim of the hub overhanging over the front of the studs by the 

same thickness as the wallboard being used. For example, if you are  

using 10mm Gib Board, ensure that the rim sits out by 10mm.  

Wallboard must surround the hub and not overlap the basket.  

Dimensions of the basket for the purpose of the hole in the wallboard 

is 285 mm x 250 mm. Depth of basket is 80 mm. A frame screws to the 

basket, and plate (complete with storage box) clips into the frame. 

Redcat/Media Connector is a teacher microphones, AV audio control-

ler, amplifier and receiver. Media Connector screws to the wall to 

cover the 30mm hole in wallboard shown. Cables run between the 

Media Connector and the UConnect Mini. If the top of the UConnect 

basket is screwed to a horizontal stud, a 30 mm hole is required in 

the stud to allow for these cables to be run between the two compo-

nents.

Speakers(s) distribute audio for best listening conditions, and hearing 

aided children can connect transmitters to receive augmentation of 

audio direct to receivers built into hearing aids.

Finished look of UConnect 

Mini and HubCover

8

HubCover for Media Connector

Using appropriate fastener/s,  

install HubCover to wall. Input  

power supply and  TV to Media 

Connector and output from 

’ALD’ on Media Connector  

to input in UConnect Mini.

3

1

2

4

5

7

6

Redcat Access 

mounts to 

the wall with 

brackets 

shown.

Redcat Access Wall Mounting Instructions

Detailed instructions at www.hearandlearn.com.au/install

Approx 1800mm from floor.  

Within reach but safe from knocks.

Reviews: