HCWB3 − By-Pass Humidifier / / Page 2

FEATURES

CONTROLS

Manual Humidistat - HCWB3-12 and HCWB3-17

Can be horizontally mounted on wall or duct.

Provides manual control of room relative humidity.

Wired in series with the humidifier water solenoid 

valve.
Adjustable setting.

Automatic Humidifier Control - HCWB3-12A and 

HCWB3-17A

Wall or duct mounted.

Automatic or manual mode control. Manual Mode label 

(with resistor to bypass outdoor temperature sensor) 

are furnished to indicate when humidistat is installed in 

Manual Mode.

Senses indoor relative humidity and outdoor 

temperature. Includes outdoor temperature sensor 

for use with automatic control option and resistor for 

manual control setting.
Adjusts humidity setpoint to provide optimum humidity 

levels within the space.
Adjustable setting.

WATER SUPPLY

Consists of supply tubing, orifice, distribution tray, 

cleanable/replaceable internal strainer and 24 volt 

brass water solenoid valve with stainless steel seat.

Drain

1/2 in. drain fitting at bottom of cabinet.
1/2 in. ID plastic tubing must be field provided.

Unused water from the evaporator pad is drained from 

the unit to help remove mineral deposits left from the 

evaporative process.

Distribution Tray

Reservoir and unique polyester liner provides even 

water distribution across the evaporator media pad for 

optimal performance.
Tray and support frame removable for cleaning or 

replacement.

Evaporator Media Pad

Provides large evaporation capacity.
Pad and support frame removable for cleaning or 

replacement.
Annual pad replacement recommended.

Saddle Valve

All necessary fittings furnished as standard equipment.

Field installs in the water supply line

OPTIONAL ACCESSORIES

Installation Kit (Canada Only)

Kit contains: 6 in. dia. duct ring flange, 2.5 ft. of 6 

in. dia. galvanized steel flexible duct, 10 ft. of 1/4 in. 

OD polyethylene water feed tube,  15 ft. of 1/2 in. 

ID clear nylon drain tube, 10 ft. of 2-conductor 18 

AWG thermostat wire, one hose clamp, two plastic 

compression sleeves, and two plastic compression 

ferrules.

MAINTENANCE SUPPLIES

Replacement Media

Recommended annual replacement of media pad.

See Specifications table for catalog number.

SPECIFICATIONS

Model No.

With Manual Humidistat Control

HCWB3-12

HCWB3-17

With Automatic Humidifier Control

HCWB3-12A

HCWB3-17A

Capacity - 120°F plenum temperature, 0.20 in. w.c. static pressure drop

12 US gallons per day

17 US gallons per day

Water Feed Rate (gallons per hour @ 50 PSI water pressure)

3

3

Evaporator pad size - H x W x D - in.

9-1/2 x 9-5/8 x 1-11/16

13 x 10 x 1-11/16

Connections

Plenum H x W - in.

9-1/2 x 9-1/2

12-3/4 x 10

By-Pass Duct  - in.

6 round

6 round

Water supply

1/4 in. compression

1/4 in. compression

Drain

1/2 in. I.D.

1/2 in. I.D.

Electrical characteristics

24V

24V

Shipping Data - lbs. (1 package)

8

9

MAINTENANCE SUPPLIES - MUST BE ORDERED EXTRA

Replacement Media

X2660

X2661

OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA

Installation Kit (Canada Only)

21N85

21N85

Summary of Contents for HCWB3

Page 1: ...nstall where freezing may occur Humidifier saddle valve and manual or automatic humidifier control depending on model shipped in one package Sequence of Operation Humidifier will only operate when indoor blower is operating When the level of moisture in the return air or living space area drops below the set point of the humidifier control the water solenoid valve opens water flows into distributi...

Page 2: ...ovable for cleaning or replacement Evaporator Media Pad Provides large evaporation capacity Pad and support frame removable for cleaning or replacement Annual pad replacement recommended Saddle Valve All necessary fittings furnished as standard equipment Field installs in the water supply line OPTIONAL ACCESSORIES Installation Kit Canada Only Kit contains 6 in dia duct ring flange 2 5 ft of 6 in d...

Page 3: ... 8 156 DIA BY PASS DUCT CONNECTION B OPENING 1 AIR FLOW NOTES By pass duct air flow direction is dependent on application For downflow applications air flow is to the humidifier from the supply air duct 1 Left hand air inlet outlet shown For right hand inlet outlet rotate humidifier cabinet 180º top for bottom and relocate drain to alternate location on cabinet See Installation Instructions for ad...

Page 4: ... VOLUME OF HOME Model No Type of Home 8 Foot Ceiling 9 Foot Ceiling 10 Foot Ceiling Home Area sq ft Home Area sq ft Home Area sq ft HCWB3 12 HCWB3 12A Loose 750 666 600 Average 1500 1350 1200 Tight 3000 2700 2400 HCWB3 17 HCWB3 17A Loose 1000 888 800 Average 2000 1800 1600 Tight 4000 3600 3200 NOTES Loose Home Two Air Change Rates per hour Typically loose in construction and is over 20 years old N...

Reviews: