HealthWay NR-20600-3NR Operation Manual Download Page 4

HealthWay AIr Purifier

TM

 Operation:

Plug the unit into a standard 120 volt earth grounded AC circuit and press either
the speed button on the control panal or the remote to the desired setting. The
control panel lights should be illuminated as follows:

Main  Filter

 - green light is 

ON (Functioning)

Pre-Filter 

 - green light is 

ON (Functioning)

Bio Monitor DFS 

- green light is 

ON (Functioning)

When the unit is operating properly, all three indicator lights will be “green”.

Main Filter Service Light:

  When the Main Filter Function light goes OFF -

this indicates that you have to replace the Main Filter and clean the wires.
The average life expectancy is 12 months. See Main Filter “cange” instruc-
tions. (Fig A-E)

Bio Monitor - (DFS) Light:

  Green light ON indicates that airborne microor-

ganisms are continuously being inactivated in the

 Filtration Grid System

. If

the light goes OFF, microorganism inactivation has been interrupted. Immedi-
ately turn off the unit and unplug it from the outlet. Call CWR customer
service at 1-800-444-3563   NOTE: Never shutt off DFS function.

The remote control 

is located in the shipping box on top of the air purifier.

When using the remote make sure you aim the remote control towards the
control panel sensor.  The remote will work up to 12 feet. To start the unit
press the desired setting, Low/Medium/High. To shut OFF unit, press the
OFF button. The battery is included (Lithium 3 Volt- CR 2025).

Pre-Filter Funciton Light: (Fig F-H)

 This is a warning light that will go OFF

in 6 months and the Pre-Filter is overdue for cleaning. Normally the Pre-filter
should be vacuumed at least once a month and reversed. Before cleaning the
unit, shut the air purifier OFF and unplug it from the outlet. Remove the 7-
Stage Pre-Filter, gently vacuum both sides of the filter.  Reverse and reinsert
into filter drawer.

***NOTE:  People with chemical and environmental (MCS) sensitivities will
detect contaminants at lower levels and will have to change filters sooner.
People with pets  or who live in very polluted areas, will need to clean and
change filters more frequently.

1

.Turn the air purifier off and unplug from power outlet.

2

.To access Main Filter, place fingertips under side re-

cesses of black cover, gently pull outward and lift cover
up to remove. Separate cover from the air purifier.
(Fig. A)

Pre-Filter Change/Cleaning Instructions:

4

.To remove Main Filter, lift filter

from the internal chamber. (Fig. C).
(To Clean- gently wipe the  wires
with alcohol swab or use com-
pressed air can to remove dust.)
Before installing the new Main Fil-
ter, make sure the black filter seal
“O” ring is seated properly in the
“O” ring channel (Fig.D).  The EGF
Filter is labeled with “

FRONT” this

must be positioned to the front
of the unit.

 (Fig.C)

 (Fig. C)

 (Fig. B)

 (Fig. A)

 (Fig. D)

 (Fig. E)

Control Panel Guide

3.

 To release Main Filter, move both

black handles 90° toward front of air
purifier. (Fig.B).  Do not force the
handles.

To Change Main Filter:

 (Fig. F)

 (Fig. G)

1.

 Turn the air purifier off and unplug from power outlet. To change/vacuum Carbon Filter, Open

back panel (Fig.F) remove panel and set it down.  Pull out Carbon Tray (Fig.G) and replace
every 12 months.  If your have high levels of particulates in your home and/or animal hair you
can easily vacuum the Pre-Filters,  between filter changes, which  are located on the underside
of the Carbon Tray, see (Fig.H). Simply vacuum the Carbon Tray Pre-filter.  Then turn the tray
over and reinsert into filter drawer. This procedure can be repeated as necessary, however, it is
highly recommended that this entire filter be replaced annually.

2. 

Reattach back panel.  Your unit is now ready for use.

 (Fig. H)

for Pre-filtration tray

6

.To replace the lid, align the 2 vertical tabs, on the inside of the lid, with the slots in the top of the

machine. Push down gently and snap shut. Plug air purifier into power outlet and turn on. (Fig. A)

Note:

 The unit will not run with top attached improperly.

5

.To load Main Filter, align hole in filter tab with brass contact (Fig.E). Press filter down.

To lock filter in place, move both black handles in 90° toward the center of the filter.

CAUTION: Do not force handles, they should move freely, if not, realign filter.

Remote Control

Remote sensor