8)  Position the extension tube to a 

 

comfortable position by manually 

 

extending or retracting the tube .

9)  Slide the variable steam control down for 

 

small-sized particles of steam. Smaller 

 

particles are ideal when inhaling steam 

 

through the nose . Slide the control up 

 

and large-sized particles will result. 

 

Larger particles are ideal when inhaling 

 

through the mouth . 

NOTE:

 Extending the tube also lowers the 

temperature of the steam .

10) Check that the POWER switch is in the 

 

‘off’ position . Plug the power cord into a 

 

main outlet .

11)  Turn the POWER switch to the ‘ON’ position.

12) Start your treatment .

13) The Steam Inhaler will begin to output 

 

steam in approximately 60 seconds . 

 

Once the level of steam becomes weak 

 

(approximately 6-9 minutues), turn the 

 

POWER switch to the ‘OFF’ position and 

 

unplug the power cord from the outlet .

IMPORTANT!

The Inhaler will automatically shut off if it 

becomes overheated . If/when this happens, 

immediately:

1) Turn the POWER switch to the ‘OFF’

 position .

2) Unplug the power cord from the outlet .

3) Allow the unit to cool for approximately 

30 minutes .

Before restarting the unit, make sure that the air 

vents on the extension tube are not obstructed .

After Every Use

1)  Unplug the unit from the power source .

2)  Allow the unit to completely cool

  (approximately 10 minutes) .

3)  Carefully remove the aromatherapy/drain 

tank and pour out any remaining water .

4)  Follow the cleaning procedures provided in 

this guidebook .

NOTE:

 Occasionally the nozzle that directs the 

steam into the extension tube may become 

obstructed . If the Steam Inhaler begins to  

produce a significanty smaller amount of steam 

or no steam at all, the nozzle needs to be 

cleaned. To clean the nozzle, remove the cover 

from the Steam Inhaler. Firmly grasp the nozzle 

and twist clockwise to remove, 

Fig. 7.

 Insert a 

fine gauge needle or the pin which is stored 

under the bottom of the Steam Inhaler into the 

nozzle to clear the airway, 

Fig. 7

 . To reattach the 

nozzle, align the nozzle brackets with the 

grooves on the nozzle base. Turn  

counterclockwise until the nozzle locks into 

place .

Troubleshooting

If any abnormality occurs during use, please 

check and correct the following:

Condition Correction

Unit does not 

Check the AC connection

operate when 

to the outlet . 

POWER switch 

 

is turned . 

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
No steam  

Check that there is water

or low rate  

in the water heater tank .

of steam

 

Check that there is 

 

saline or aromatherapy 

 

water in the

 

aromatherapy/drain tank 

 

(if applicable) .

 

Make sure that suction 

 

tube and other components  

 

are properly attached .

 

Make sure that the steam 

 

nozzle is clean. Remove 

 

nozzle and clear the airway  

 

with the pin or fine gauge  

 needle .

5

Fig. 7