10

10

5.

If the Index line falls within the OK range, indicated at the edge of the
cuff, this cuff is suitable for your use. 

If the Index line falls outside of

the OK range, you may need a larger cuff for accurate measurement.
Please consult your local retailer for the purchase of a larger cuff
or visit the Health o meter

®

website at www.healthometer.com.

Sit in a chair with your feet flat on the floor. Rest your left arm on a table
so that the arm cuff is at the same level as your heart.

Taking a Measurement

1.

Press the POWER button. All display segments will appear
for approximately one second before returning to “0.”

2.

The unit will automatically start to inflate slowly to measure your blood
pressure. During inflation, a changing measure of the cuff pressure
will be shown on the display.

5.

Si la línea de Índice cae dentro del espacio OK, indicado en el borde del

brazalete, este brazalete es adecuado para su empleo

. Si la línea de Índice

cayera fuera del rango OK, es muy posible que usted requiera un brazalete

más grande para obtener una medición precisa. Por favor consulte con su

distribuidor local para comprar un brazalete más grande o visite las páginas

de Internet del Health o meter® en el www.healthometer

.com.

Siéntese en una silla con los pies planos en el piso. Descanse su brazo izquierdo sobre

una mesa de modo que el brazalete de brazo esté al mismo nivel que su corazón.

Tomando una Medición

1.

Presione el botón POWER. Todos los segmentos de pantalla aparecerán

pormás o menos un segundo antes de volverse un “0”. 

2.

La unidad empezará a inflarse automática y lentamente para medir su presión

arterial. Durante el inflado, la presión cambiante del brazalete será mostrada

en la pantalla.

7631 01 Text Eng y Español  17-06-2002  14:32  Page 18

Summary of Contents for 7631

Page 1: ...Your Measure for Good Health UPPER ARM Blood Pressure Monitor with ComfortRead Technology...

Page 2: ...STRUCTIONS DO NOT DESTROY Features Fully Automatic One Touch Operation Extra Large Easy To Read Digital Display 90 Automatic Memory Feature ComfortRead Technology Minimizes Cuff Pressure Maximizes Com...

Page 3: ...y 5 About Blood Pressure 5 Blood Pressure Standard 6 Blood Pressure Fluctuation 6 Display Explanations 7 Installing Batteries 7 8 HOW TO USE 8 11 Helpful Tips 8 Applying the Arm Cuff 9 10 Taking a Mea...

Page 4: ...or is to be used by an adult and is intended for in home use Note Please read this manual carefully before use For specific information about your own blood pressure contact your physician Please be s...

Page 5: ...EN 1060 1 Dec 1995 Non invasive blood pressure measuring equipment General requirements EN 1060 3 Feb 1997 Non invasive blood pressure measuring equipment Supplementary requirements for electromechani...

Page 6: ...your optimal blood pressure range Blood Pressure Fluctuation Blood pressure fluctuates all the time Blood pressure will change over the course of the month week and even throughout the day It is also...

Page 7: ...batteries should be replaced Shows the Pulse Rate per minute Occurs when an error was made during measurement Installing Batteries 1 Press down and lift the battery cover in the direction of the arro...

Page 8: ...are a few tips to help you obtain more accurate readings Do not measure your blood pressure immediately after consuming a large meal To obtain more accurate readings please wait one hour before measu...

Page 9: ...Put your left arm through the cuff loop The OK range indication should be positioned at the top with the rubber tube pointing downward in the direction of your forearm Position the artery mark over th...

Page 10: ...site at www healthometer com Sit in a chair with your feet flat on the floor Rest your left arm on a table so that the arm cuff is at the same level as your heart Taking a Measurement 1 Press the POWE...

Page 11: ...the systolic diastolic and pulse reading into memory The last 90 measurement readings will be saved into memory 4 Measurement is now complete Press the POWER button to turn the unit off The unit will...

Page 12: ...No display when the POWER button is pressed EE mark shown on the display or the blood pressure value is displayed excessively low or high Check Point Have the batteries run down Have the batteries bee...

Page 13: ...e suffered from stroke or for unconscious users this device may not be suitable for use 8 Your Health o meter Blood Pressure Monitor can be cleaned with a soft dry cloth Never use an abrasive cleanser...

Page 14: ...ge the terms and conditions of this warranty This warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper volt...

Page 15: ...AS IMPORTANTES Your Measure for Good Health DE BRAZO Medidor de Presi n Arterial con Tecnolog a ComfortRead este manual entero cuidadosamente antes de usar este dispositivo Modelo 7631...

Page 16: ......

Page 17: ...compra de su nuevo Monitor de Presi n Arterial de Brazo Modelo 7631 Este aparato totalmente autom tico es f cil de ecuado para tomar mediciones diarias La pantalla grande incluye st lica la diast lic...

Page 18: ......

Page 19: ...la presi n arterial RCA DE LA PRESI N ARTERIAL si n Arterial s la presi n ejercida contra el interior de la pared arterial sangre a trav s de la arteria La presi n medida cuando el y env a la sangre...

Page 20: ......

Page 21: ...l pulso Por minuto Ocurre cuando se ha cometido un error durante la medici n e las Bater as ante la tapa de las bater as en la direcci n de la flecha ompartimiento de bater as place 4 bater as de 1 5...

Page 22: ......

Page 23: ...ria s principales en el lado interior de su brazo como se muestra bajo El tubo debe correr hacia abajo por el centro de su brazo izquierda hacia arriba y coloque el borde del brazalete de adamente 1 p...

Page 24: ......

Page 25: ...a memoria ras de mediciones ser n almacenadas en la memoria completa ahora Presione el bot n POWER para apagar se apagar autom ticamente despu s de un minuto iona ning n bot n emorias as almacenadas d...

Page 26: ......

Page 27: ...onsulte con su m dico antes de su empleo er limpieza de su Monitor de Presi n Arterial Health o meter uave seco Nunca utilice un limpiador abrasivo ni sumerja el ua ni en ning n otro l quido nes Oscil...

Page 28: ......

Reviews: