Health O Meter 3001KL-AM User Instructions Download Page 10

10 

SET-UP INSTRUCTIONS  

For Pre-Assembled Scales 

1.  Remove the fully assembled scale by carefully lifting it out from the carton and place 

scale platform on a flat, level, and dry surface. 

2.  Remove the protective plastic film covering the display head (the film is printed 

“FACTORY CALIBRATED”). 

3.  Carefully remove the batteries that are wrapped in bubble wrap and attached to the 

handrail. See 

Powering the Scale 

or 

Battery Installation,

 below, for battery and 

AC adapter instructions.  

 
 

Powering the Scale 

1.  Plug the AC adapter into the power adapter jack (the jack is located on the rear of 

the display head), then plug the sca

le’s AC adapter into the power source. 

 

Warning: 

To avoid a safety hazard, do not use an unspecified AC adapter. Only use 

the Health o meter® Professional AC adapter model ADPT30 designed for this scale.   

 

 

 

 

 

 

 

2.  For battery operation, see Battery Installation below. 

 

Battery Installation 

1.  If connected, unplug the AC adapter from the power source. 
2.  Use a Phillips head screwdriver to remove the battery cover on the side of the 

display head by unscrewing the (2) battery cover screws. 

3.  Replace or install fresh batteries, making sure to install them in the proper direction.  

Health o meter Professional recommends using an alkaline or lithium battery, rated 
for 130°F (54°C) operation.  Do not use Zinc-Carbon batteries. 

4.  Re-attach the battery cover to the display head. 

Warning:

 If the scale will not be used for some time, remove the batteries to avoid a 

safety hazard. Disposal of batteries must be performed in accordance with the 
prevailing national, regional or local regulations that apply to you.   

 

 

 

 

 

 

 

 

Power Adapter 

Jack 

Summary of Contents for 3001KL-AM

Page 1: ...1 Model 3001KL AM 3001KL AMX Antimicrobial Digital Platform Scale User Instructions P N UM3001KL AM 3001KL AMX Rev20170921_EngOnly...

Page 2: ...ecifications 4 Certifications Connectivity Disposal 5 Assembly Instructions 6 Set up Instructions 10 Operating Instructions 11 Maintenance 15 Calibration 16 Troubleshooting 17 Warranty 18 Note This sc...

Page 3: ...ation Ensure that the AC adapter outlet is wired to a circuit breaker or other protected power source Unplug the AC adapter and carefully store both the adapter and adapter cord before moving the scal...

Page 4: ...factory locked in KG mode Refer to Page 12 to learn more about configuring the scale Antimicrobial Powder Coating Unique to the 3001KL AM 3001KL AMX scales the handrails and transport handle have bee...

Page 5: ...lable during normal business hours at 1 800 638 3722 Scale Disposal This Health o meter Professional scale must be disposed of properly as electronic waste Follow the national regional or local regula...

Page 6: ...ly remove each assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid damaging the scale parts when unpacking do not use a box cutter knife scissors or any...

Page 7: ...e completely hand tightened 2 Turn the platform over so it is facing up Locate the handrail and untie the load cell cable connector Position the handrail over the handrail supports on the platform and...

Page 8: ...forward to access the underside of the platform Plug the load cell connector cable into the port 6 Carefully tilt the scale back to an upright position Obtain the display head and align the four hole...

Page 9: ...ell port on the rear of the display head 8 Attach the adapter holder to the handrail using the 2 included sheet metal screws Use a Phillips head screwdriver to tighten the screws The scale is now asse...

Page 10: ...ified AC adapter Only use the Health o meter Professional AC adapter model ADPT30 designed for this scale 2 For battery operation see Battery Installation below Battery Installation 1 If connected unp...

Page 11: ...culate patient s Body Mass Index BMI RECALL Recalls the previous weight TARE PRETARE TARE Deducts the weight of an object on the platform PRETARE Prompts entry of a weight value that will be deducted...

Page 12: ...turn on the scale 3 Wait until the 0 0 LB or 0 0 KG appears on the display 4 Ask the patient to step on the scale The scale will begin to display the patient s weight and will lock on the patient s w...

Page 13: ...manually by using the keypad or automatically as outlined in this section Tare 1 With all weight off the scale press the ON OFF button to turn on the scale 2 Wait until the 0 0 LB or 0 0 KG appears o...

Page 14: ...s weight 4 Press the TARE button The scale will zero out and the word TARE will appear at the bottom center of the display indicating that there is a tare value for the parent s weight 5 Ask the paren...

Page 15: ...ble inspect the AC adapter for cord cracking fraying and for broken bent prongs Cleaning Proper care and cleaning is essential to ensure a long life of accurate and effective weighing Caution Disconne...

Page 16: ...and ZERO button while pressing the ON OFF button Two alphanumeric characters will appear next to U followed by 4 5 characters U XX followed by a 4 5 digit idle scale count number 2 Press the ENTER bu...

Page 17: ...y balanced 3 Place the scale on a level floor Tighten the feet on the underside of the platform to ensure all 4 feet are properly balanced 4 Scale is out of calibration 4 Check weight with known weigh...

Page 18: ...contrary to the operating instructions abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover natural disasters such as fire flood hurri...

Reviews: