background image

10

Features

Keeps medications within the USP Standard for Controlled Cold 

• 

Temperature USP 32 – 2009.
Can be a stand-alone (desktop) unit or attached to a wall or surface 

• 

with a wall mount bracket. HCL provides a range of mounting 
brackets to choose from.
Compact, lightweight and perfect for patient room applications.

• 

Meets the American with Disabilities Act of 1990 wall mount 

• 

guidelines of 4" depth.
Solid-state design; integrated chip design; silent operation; 

• 

thermostatically controlled.
Provides for 2-liter storage space or 124.3 cubic inches. 

• 

Overall Dimensions: 15"L x 3

• 

13

16

"W x 8"H (381mm x 97mm x 203mm) 

Tips

The unit is not frost free and will collect moisture inside. Periodically 
wipe the bottom surface of the inside of the unit with a paper towel to 
absorb the moisture. 

Thermoelectric cooling works via the transfer of thermal energy from 
one surface to another. Make sure that items are always in contact 
with the cooling surface or adjacent vials/bags, etc. – the key is 
contact. Do not utilize shelves or racks that suspend the product in 
the open air inside of the unit. 

Note:

 Make sure the glycol thermometer bottle is positioned in the corner per the 

instruction sheet on page 7 to ensure accurate readings.

Make sure the door hinge area is clean and free of debris. Large 
debris can obstruct the hinge and damage the door, or prevent the 
unit from shutting completely.

Make sure the glycol thermometer vial cord is laying flat and exiting 
the top corner of the door. It is important to minimize any door 
obstruction to avoid excess loss of temperature within the unit. See 
page 7.

Summary of Contents for 17976

Page 1: ...rvice Station with Petite Fridge 17976 Health Care Logistics Inc 2011 1 Step 1 Mark drill locations as desired four places Try to hit a stud with two of the four 2 Step 2 Drill holes to fit mount hardware be sure to use hardware that is flush mount flat headed screw Obstructions on the back wall of the cabinet will interfere with the tilter bin function ...

Page 2: ...ridge 17976 Health Care Logistics Inc 2011 5 Step 5 Once level drive the remaining screws flush 6 7 8 Step 6 Cabinet mounted Step 7 Place the bins back inside of the unit as they were removed Step 8 Unit with bins installed 3 Step 3 Drive the first screw flush with the back 4 Step 4 With one screw in the unit place a level on the top of the Service Station and straighten in place ...

Page 3: ...eLogistics com Email hcl HealthCareLogistics com ASSEMBLY INSTRUCTIONS FOR Wall Mount Service Station with Petite Fridge 17976 Health Care Logistics Inc 2011 9 Step 9 The bin should tilt forward and rest against the upper dowel pin 10 Step 10 Bin is in closed position ...

Page 4: ... Information Read and follow all instructions and warnings prior to using this product SAVE THESE INSTRUCTIONS Includes Refrigerator Power Supply Traceable Memory Monitor Refrigerator Thermometer Dual Lock for power supply mounting Dual Lock for probe mounting Call Free 1 800 848 1633 or 1 888 HCL INTL Fax Free 1 800 447 2923 Website www HealthCareLogistics com Email hcl HealthCareLogistics com ...

Page 5: ...s 8 About Thermoelectric Cooling How It Works 9 Features 10 Tips 10 Cleaning and Maintenance 11 Troubleshooting 12 Product Specifications 12 Capacity A Dimensions Weigh B t Power Supply Requirements C Power Cor D d Cooling Performanc E e Thermostat Control F Material Composition G Insulatio H n Heat Dissipation I Electrical Equipment J Accessories Replacement Parts 14 HCL s Hassle Free Return Poli...

Page 6: ... to a power source when it is in an enclosed area such as a cabinet or a drawer Unplug the refrigerator before cleaning and making repairs Because of potential safety hazards under certain conditions we strongly discourage the use of an extension cord However if you must use an extension cord it is absolutely necessary that it be a UL listed in the U S or CSA listed in Canada 3 wire grounding type...

Page 7: ...o 46ºF The user cannot change or select the desired temperature Allow 24 hours for the temperature to stabilize to preset 6 recommended settings This unit will not chill items as fast as a conventional refrigerator 7 Please don t expect it to do so An empty refrigerator will cool down in about 3 hours Warm items placed in the refrigerator will slow the cooling rate as will the amount of items plac...

Page 8: ...as not pull the barrel connector out of the refrigerator 3 Step 1 Peel the protective backing from the dual lock Mounting Power Supply HCL recommends attaching the power supply to the wall or a surface with the provided dual lock tape If the unit is not attached the weight of the power supply could cause the unit to come unplugged Note Wire tie the remaining wire with the provided wire ties so it ...

Page 9: ...he set points of 36ºF to 46ºF or the USP Standard Range for Controlled Cold Temperature It is important to place the probe in the refrigerator so that the wire exits the refrigerator door in one of the upper corners to the door adjacent to the top of the unit The unit can be mounted on the wall with Velcro dual lock or double sided tape See next page for proper placement mounting of probe Note Ope...

Page 10: ...r Press the dual lock side of the probe against the dual lock in the refrigerator Step 5 When closing the Fridge door guide the wire from the thermometer out the top on an angle Make sure the cord lays flat to minimize air leak 1 Step 1 Gather probe one piece of dual lock Peel the protective backing from the dual lock Note This probe location in the photos above will be the same for wall mount or ...

Page 11: ...cool as much as 35ºF 19 4ºC below room temperature The USP Standard Range for Controlled Cold Temperature is between 36ºF and 46ºF The optimum room temperature range of operation is between 69ºF and 73ºF The internal thermostat will automatically activate to keep the temperature within USP limits at the low end of the range The user cannot change or select the desired temperature How the Unit Work...

Page 12: ...ate temperature switch works thermostatically to maintain the optimum temperature range as prescribed by the USP Standard for Controlled Cold Temperature of 36ºF to 46ºF The user cannot change or select the desired temperature Instead of plugging the unit into your vehicle HCL built the unit to utilize a UL approved Medical Grade power supply that connects to a wall socket The unit has only one mo...

Page 13: ... bottom surface of the inside of the unit with a paper towel to absorb the moisture Thermoelectric cooling works via the transfer of thermal energy from one surface to another Make sure that items are always in contact with the cooling surface or adjacent vials bags etc the key is contact Do not utilize shelves or racks that suspend the product in the open air inside of the unit Note Make sure the...

Page 14: ...oler than the water vapor Some examples might include vials being removed from the unit and placed in a container when the door is opened and closed and the contents are cooler than the moist air inside the unit or during periods of high humidity when there is a difference in vial and air temperature At times condensation may build up on the contents of the unit which may in turn become frosted In...

Page 15: ... Shipping Dimensions 161 2 L x 91 2 H x 51 2 W Empty Weight 4 lbs Shipping Weight 6 lbs Power Supply Requirements Unit operates on 12V DC Unit is supplied with a 100 240V AC adapter for wall sockets The unit consumes 4 5 amps of 12V DC power Power Cord The MPU60B series of AC DC switching mode power supplies provide 63 Watts of continuous output power All supplies are UL94V 1 min compliant and inc...

Page 16: ... change or select the desired temperature Thermostat Control Chip in unit automatically cycles On Off to maintain USP Temperature Range for Controlled Cold Temperature The user cannot change or select the desired temperature Material Composition ABS plastic housing with polystyrene insulation material Insulation CFC Free Heat Dissipation Built in fan long lasting brushless motor Electrical Equipme...

Page 17: ...d on our website at www HealthCareLogistics com Accessories Replacement Parts A 18102 Petite Fridge no lock B 18103 Petite Fridge with Keyless Entry Digital Lock C 18104 Petite Fridge with Key Lock D 18105 Universal Locking Mount for Petite Fridge with Keyless Entry Digital Lock E 18106 Universal Locking Mount for Petite Fridge with Key Lock F 17840 Wall Mount System for Petite Fridge D E F A B C ...

Page 18: ... abuse accident or neglect such as physical damage cracks scratches etc to the surface of the product resulting from misuse b contact with harsh chemicals or submersion in water or exposure to the elements or extreme heat c use of non approved accessories or subjecting the product or accessory to abnormal usage or conditions d connecting the 100 240VAC power adapter to a power source other than th...

Page 19: ...Call Free 1 800 848 1633 or 1 888 HCL INTL Fax Free 1 800 447 2923 Website www HealthCareLogistics com Email hcl HealthCareLogistics com ...

Page 20: ...Email hcl HealthCareLogistics com Health Care Logistics Inc 2011 INSTRUCTIONS FOR Battery Replacement on the Digit Lock 1 Step 1 Place the key in the lock and open the door 2 Step 2 If the key is not available a 9V battery can be placed on the terminals on the underside of the lock ...

Page 21: ... housing from the cabinet 6 7 8 Step 6 Remove the middle screw Step 7 Remove the top screw Step 8 Swivel the lock to the side to allow access to the batteries 3 Step 3 Enter the code while keeping the 9V battery in contact with the terminals and open the door 4 Step 4 Use a Phillips head screwdriver to remove the two screws on the lock housing be sure to hold the lock housing in the opposite hand ...

Page 22: ...00 447 2923 Web www HealthCareLogistics com Email hcl HealthCareLogistics com INSTRUCTIONS FOR Digit Lock Health Care Logistics Inc 2011 9 Step 9 Replace the batteries and repeat the steps to mount the unit back on the side of the cabinet ...

Page 23: ...Call Free 1 800 848 1633 Fax Free 1 800 447 2923 Web www HealthCareLogistics com Email hcl HealthCareLogistics com Health Care Logistics Inc 2011 INSTRUCTIONS FOR Programing the Digit Lock ...

Page 24: ...Call Free 1 800 848 1633 Fax Free 1 800 447 2923 Web www HealthCareLogistics com Email hcl HealthCareLogistics com INSTRUCTIONS FOR Digit Lock Health Care Logistics Inc 2011 ...

Reviews: