Safety Information (continued)  

PERSONAL  SAFETY  (CONTINUED) 

3.    Do not wear loose clothing or jewelry. Contain long 

hair.  Keep  your  hair,  clothing,  and  gloves  away  from  moving 

parts.  Loose  clothes,  jewelry,  or  long  hair  can  be  caught  in 

moving parts. 

 
4.    Keep proper footing and balance at all times. Proper 

footing  and  balance  enables  better  control  of  the  tool  in 

unexpected situations 

 
5.    Do not use on a ladder or unstable support 
 

AIR      COMPRESSOR        AND        PNEUMATIC      TOOL 

SAFETY 

WARNING: Do not attempt to modify this tool or 
create accessories not recommended for use with 
this tool. Any such alteration or modification is 
misuse and could result in a hazardous condition 
leading to possible serious personal injury. 
 
 

CAUTION: Do not use in an environment that is 
dusty or otherwise contaminated. Using the air 
compressor in this type of environment may cause 
damage to the unit. 

 

1.  Keep compressors as far from the spraying area as 

possible, at least 15 ft. from the spraying area and all 

explosive vapors. 

2.    Risk of Bursting. Do not adjust regulator to result in  
 

output pressure greater than marked maximum pressure  

 

of attachment. Do not use at pressure greater than the  

 

rated maximum pressure of this compressor. 

3.     If connected to a circuit protected by fuses, use time- 

 

delay fuses with this product. 

4.  To reduce the risk of electric shock, do not expose to 

rain. Store indoors. 

 

5.  Ensure the hose is free of obstructions or snags. 

Entangled or snarled hoses can cause loss of balance or 

footing and may become damaged. 

 

6.  Use the air compressor only for its intended use. Do not 

alter or modify the unit from the original design or 

function. Never weld or drill holes in the air tank. 

 

7.     Never leave a tool unattended with the air hose 

attached. 

 

8.     Do not operate this tool if it does not contain a legible 

warning label. 

 

9.     Do not continue to use a tool or hose that leaks air or 

does not function properly. 

 

10. Do not attempt to pull or carry the air compressor by 

the hose. 

 

11. Your tool may require more air consumption than this 

air compressor is capable of providing. 

 

12. Never direct a jet of compressed air toward people or 

animals. 

 

13. Protect your lungs. Wear a face or dust mask if the 

operation is dusty. 

 

14. Do not use this air compressor to spray chemicals. Your 

lungs can be damaged by inhaling toxic fumes. A 

respirator may be necessary in dusty environments or 

when spraying paint.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Please contact 

800-514-6729

 for further assistance. 

Summary of Contents for TAW-0412P

Page 1: ...m EST Monday Friday 800 514 6729 figure THANK YOU We appreciate the trust and confidence you have placed in HDX through the purchase of this 3 gallon portable air compressor W strive to continually cr...

Page 2: ...before making adjustments servicing a tool or when a tool is not in use 5 This compressor pump is not equipped and should not be used to supply breathing quality air Additional equipment would be nece...

Page 3: ...ent Do not use at pressure greater than the rated maximum pressure of this compressor 3 If connected to a circuit protected by fuses use time delay fuses with this product 4 To reduce the risk of elec...

Page 4: ...e a drop in line voltage resulting in a loss of power and causing the motor to overheat Use the following chart to determine the minimum wire size required in an extension cord 3 Only use 100 feet or...

Page 5: ...s may vary This warranty applies only to the original retail purchaser and may not be transferred This warranty does not cover normal wear and tear or any malfunction failure or defect resulting from...

Page 6: ...ning horsepower 0 25 HP Air tank capacity 2 gal Air pressure 100 PSI max Air delivery 0 6 SCFM at 40 PSI 0 7 SCFM at 90 PSI Lubrication Oil Free Gauges 2 gauge 1 5 in diameter Input 120 V 60 Hz AC onl...

Page 7: ...cription A Handle B Manual on off switch C Safety valve D Rubber foot E Tank F Quick coupler G Pressure regulator knob H Tank pressure gauge I Regulator pressure gauge J Drain valve 6 Please contact 8...

Page 8: ...compressor automatically shuts off when the pressure reaches the preset maximum Turn off the air compressor Pull the ring on the safety valve C for 20 seconds to release the air Release the ring Air s...

Page 9: ...n the tank pressure drops the compressor will turn on to cut in pressure Ensure the compressor is plugged into a good outlet Replace the shop house fuse Reset the shop home breaker and determine the u...

Page 10: ...lems missing parts Before returning to the store call Husky Customer Service 8 a m 6 p m EST Monday Friday t800 514 6729 f Retain this manual for future use R E V 0 4 0 3 2 0 1 2 PDF pdfFactory Pro ww...

Reviews: