HDOEI SP50 Maintenance Manual Download Page 2

 

SP50/SP50A Automatic Laser Level 

 

Content list 

1. Preface 

1-1 Notes 

1-2 Scope of Repairing 

1-3 Spare parts and Figures 

1-4 Procedure for Disassembly and Re-assembled 

1-5 Flow chart for Trouble shooting 

2. Accuracy 

Checking 

2-1 Horizontal Accuracy Checking 

2-2 Vertical Accuracy Checking 

3.  Accuracy calibrations 

3-1 Horizontal Accuracy calibrations 

3-2 Vertical Accuracy calibrations 

 

Preface 

Never attempt to look at the laser beam directly. Laser beam is harmful for eye. 

It is safer when laser beam rotating. Because passing through only for a short time. 

 

1-1 Notes 

SP50 is an automatic electronic laser level with laser diode of 635nm wavelength. Before repairing,   

pay great attention to important precaution as follows. 

„

 

Description of the laser unit 

Be sure good body grounding to prevent laser diode from short life time caused by static electricity 

in the unit. 

 

1.  Before disconnecting the plugs of the laser unit from the jack, turn power switch off. 

2.  Don’t touch the PCB of laser unit by hand. 

3.  Use special battery as power supply. Avoid as possible to use AC-DC stabilizer. 

4.  Don’t operate to switch ON-OFF repeatedly during short time. The PCB of the unit replacing and 

the compensator repairing should be performed by manufacturer. It is also recommended to entrust 

the manufacturer to solve the difficulties, when replacing parts and repairing dampness parts. 

Introduction of maintenance instruction manual 

This maintenance instruments manual is used only for checking and adjusting without special 

instruments for SP50 laser level with visible laser rays of wavelength 635nm. 

 

1-2 Scope of Maintenance 

The instrument is provided after adjusted. Don’t disassemble the instruments or attempt to perform 

any internal servicing, except instructions noted and permitted in this manual. 

 

 

 

 

Summary of Contents for SP50

Page 1: ...Maintenance Manual Issued 18th Feb 2006 Revised Auto Laser Level SP50 SP50A Changzhou Huada Kejie Opto Electro Instrument Co Ltd ...

Page 2: ...aser diode from short life time caused by static electricity in the unit 1 Before disconnecting the plugs of the laser unit from the jack turn power switch off 2 Don t touch the PCB of laser unit by hand 3 Use special battery as power supply Avoid as possible to use AC DC stabilizer 4 Don t operate to switch ON OFF repeatedly during short time The PCB of the unit replacing and the compensator repa...

Page 3: ...1 3 Spare parts and Figures ...

Page 4: ...B001 ...

Page 5: ...t screw 1 103 Waterproof rubber 1 23 Spring 1 104 Lock pin 2 24 Main frame 1 105 Battery spring single 1 25 Motor frame 1 106 Battery spring double 1 26 Universal bearing 1 108 Metal cover 1 27 Plastic supporter 1 111 Battery cable 1 28 Limiting joint 1 112 Main control PCB 1 29 L supporter 1 130 Screws 6 30 Pin 2 132 Screws 4 31 Rotation head 1 135 Screws 4 32 Penta prism 1 137 Screws 1 33 Rotati...

Page 6: ...canning Rotation Motor Y Step Motor X Step LD Module Y Range Limiting X Range Limiting Keypad A Keypad B Sensor X Sensor Y Sensor Z Step Motor Y LD Module Y Range Step Motor X X Range Scanning Rotation Motor Sensor X Sensor Y Sensor Z ...

Page 7: ... adjusting parts A004 A005 remove the screws which fix the rotating motor module A006 Take off A006 Remove four screws which fix 112 and take off main control PCB 112 1 5 Flow chart for trouble diagnosis 1 5 1 Description After adjusting unit not to be leveling After turning on the unit the unit will not stop making leveling and laser beam will blink and will not rotate 1 5 2 After inclining unit ...

Page 8: ...If the marks are not close enough more than 2mm the X direction needs to be calibrated Check the Y direction same way as X direction 2 2 Vertieal accuracy checking Put the unit in vertical direction and place it on a flat plate 3m away from a plumb line Hanging a ball in a wire with height 2 5m apart from the unit If the unit needs calibration it is better in a dark room Adjusting the foot screws ...

Page 9: ...ress the key CAL to change to Y Calibration Y indication light blinking Calibrating Y is same way as calibrating X After calibrating Y press the key CAL to save the data and to go back to normal operation from calibrating Then press the key I O to turn off the unit 3 2 Vertical accuracy calibrating Put the unit in vertical Turn on the unit After leveling press the key CAL for five seconds Then Z i...