HDE CDM-50 Operating And Instruction Manual Download Page 3

3

INTRODUCTION

The Cable Distance Meter is a unique, handheld instrument, primarily used for the
measurement of the height of overhead cables. The Cable Distance Meters measure
up to 6 cables.

The CDM-50 model measures to a height of up to 50 feet (15m). The CDM-75 model
has an increased range of up to 75 feet (23m). The unit operates by transmitting an
ultra-sonic signal towards the wires, and measuring the time it takes to pick up the
echo from that signal. It automatically compensates for the fact that the speed of
sound varies with temperature by monitoring the ambient temperature using the
internal temperature sensor. The display continuously shows the ambient temperature
reading. Because the temperature sensor reacts relatively slowly to large temperature
changes, it is necessary to wait up to 10 minutes for the temperature reading to stabilize
after taking the meter suddenly from a warm to a cold environment before taking a
measurement, e.g. taking the unit from inside a warm vehicle to outside. Isolate the
CDM from any hot surface such as sun warmed pavement using a notebook or several
sheets of paper.

Cone

Transducer

Temp Indicator

Measurement Units

Height Measurement

ON Switch

CAL Mode

Stored Measurements

Temperature Sensor

Read Stored Measurements

Make Measurement

Clear memory

Battery Compartment

(Side of Unit)

Summary of Contents for CDM-50

Page 1: ...CDM 50 CDM 75 C A B L E D I S TA N C E M E T E R S Operating Instruction Manual 1475 Lakeside Drive Waukegan Illinois 60085 U S A 847 473 4980 fax 847 473 4981 website www HDElectricCompany com ...

Page 2: ...2 ...

Page 3: ...g the ambient temperature using the internal temperature sensor The display continuously shows the ambient temperature reading Because the temperature sensor reacts relatively slowly to large temperature changes it is necessary to wait up to 10 minutes for the temperature reading to stabilize after taking the meter suddenly from a warm to a cold environment before taking a measurement e g taking t...

Page 4: ...hold the MEASURE key to take a measurement The distance to the first cable is shown intheHeightMeasurement locationinthedisplay Ifthereismorethanone cablepresent the difference in height between each cable is stored in memory 6 Press the READ CABLES 1 6 key to display each of the cable height differences stored in memory Stored Measurements The unit will automatically turn off 3 minutes after the ...

Page 5: ...herefore the meter should not be used in rain or snow If water does get into the cone leave it upside down in a dry warm area If the display shows this indicates a poor target and normally happens when the cables are moving due to wind etc Wait until the wind dies down to get an accurate reading CALIBRATE MODE The Calibrate mode switch allows the user to periodically check the unit to ensure that ...

Page 6: ...ement andWALL for horizontal distance to object measurement Ensure no walls or similar obstructions are within 7 feet 2m of either side of the unit as reflections from these can interfere with correct operation SPECIFICATIONS Model CDM 50 Model CDM 75 1 inch 25mm Cable Diameter 10 50 3m 15m 10 75 3m 23m 0 5 inch 12mm Cable Diameter 10 50 3m 15m 10 50 3m 15m 0 25 inch 5 5mm Cable Diameter 10 40 3m ...

Page 7: ...1 4m 50ft 15m 75 ft O ft 0 5 in 12mm 1 in 25mm 1OO ft Minimum Cable Diameter 50 ft 50ft 15m 3ft 0 9m Beam Width 3ft 0 9m 40ft 12m 33ft 10m 33ft 10m 33 ft O ft 0 125 in 2 5mm 0 25 in 5 5mm 0 5 in 12mm 1 in 25mm PERFORMANCE CDM 50MeasurementversusCableDiameter CDM 75MeasurementversusCableDiameter ...

Page 8: ...olete unavailable over time end of life In the event that a Product cannot be repaired or replaced due to unavailability of parts HD Electric Company will use commercially reasonable efforts to obtain substitute parts or conduct work around design but cannot guarantee its ability to do so Items not found defective will be returned at your expense or failing receipt of instruction from you on retur...

Reviews: