32
ARC 800 Order No. BA 93-10-0702A Issue 01.03.08
5.6
Switching on the Power Unit
Improper operation of the stud welding unit is
LIFE-THREATENING!
First read the safety instructions in chapters 1, 3 and 5.
Insert the primary plug of the power unit into an appropriate socket.
Switch on the power unit with the mains switch.
The digital display shows the adjusted charging voltage.
The digital display shows the adjusted welding time.
There is a luminous indication (LED) to the left of the display:
Green –
on, power unit is ready for welding
Red
– on, power unit is locked
•
after welding, until there is electrical contact with the
workpiece
•
if the power unit is overheated (the display shows 8 ... 2).
After a short cooling period, the work can continue.
Green –
lights if the solenoid of the welding gun is controlled
Green –
lights if the welding gun button is triggered
Green –
lights if there is electrical contact between welding element
and workpiece.
Summary of Contents for 93-10-0702A
Page 1: ...ARC 800 Power Unit 93 10 0702A Operating Manual...
Page 8: ...viii ARC 800 Order No BA 93 10 0702A Issue 01 03 08...
Page 47: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 47 Power unit ARC 800 93 10 0702A...
Page 49: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 49 Front plate complete ARC 800 88 11 268A...
Page 53: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 53 Rear wall complete ARC 800 88 11 259A...
Page 55: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 55 Bottom unit complete ARC 800 88 11 386...
Page 57: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 57 Shielding gas module ARC 800 93 50 020...
Page 61: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 61 Transformer board 80 80 491...
Page 62: ...62 ARC 800 Order No BA 93 10 0702A Issue 01 03 08 8 3 Electrical Circuit Diagram...
Page 72: ...72 ARC 800 Order No BA 93 10 0702A Issue 01 03 08 Service Support...
Page 76: ...76 ARC 800 Order No BA 93 10 0702A Issue 01 03 08...
Page 77: ......