Electrical connection
Z16A
A04000_03_Y00_00
HBM: public
13
7
Electrical connection
The following can be connected for measurement signal conditioning:
S
Carrier-frequency amplifiers
S
DC amplifiers
designed for strain gage measurement systems.
The load cells are delivered with a six-wire configuration. Optionally available
with different cable lengths.
7.1
Connection in six-wire configuration
white
black
gray
Excitation voltage (+)
green
red
Shield / drain wire connected to
transducer housing
Excitation voltage (-)
Sense lead (-)
Measurement signal (+)
blue
Sense lead (+)
Measurement signal (-)
Fig. 7.1
Pin Assignment
With this connector pin assignment, the output voltage at the measuring
amplifier is positive in the tensile direction when the transducer is loaded.
7.2
Connection in four-wire configuration
When transducers in a six-wire configuration are connected to amplifiers in a
four-wire configuration, the sense leads of the transducer must be connected
to the corresponding excitation voltage leads: Marking (+) with (+) and marking
(-) with (-),
. This measure also reduces the cable resistance of the
Summary of Contents for Z16A
Page 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 25: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 47: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 70: ...Dimensions 24 A04000_03_Y00_00 HBM public Z16A...
Page 71: ...Dimensions Z16A A04000_03_Y00_00 HBM public 25...