Specifications
24
A1461-2.0
HBM: public
C16i
7
Specifications
Type
C16i D1
Max. capactity (E
max
)
20 t
30 t
40 t
60 t
Accuracy class accord. to OIML R60
Max. numbers of load cell verification inter
vals (n
LC
)
D1 (0.0330 %)
1000
Min. load cell verification interval
(v
min
)
% of
E
max
0.0200
Min. scale verification interval (e
min
)
acc. to EN 45 501
kg
-
-
-
-
Sensitivity (C
n
)
digit
1 000 000
Sensitivity tolerance
%
"
0.0100
Temperature effect on sensitivity
(TK
C
)
% of C
n
/ 10 K
"
0.0250
Temperature effect on zero signal
(TK
0
)
"
0.0285
Hysteresis error (d
hy
% of C
n
"
0.0330
Non‐Linearity (d
lin
"
0.0300
Creep (d
cr
), 30 min.
"
0.0330
Reference excitation voltage (U
ref
)
V (DC)
12
Nominal range ofexcitation voltage
(B
U
)
Current consumption
mA
50
Resolution
Bit
20 (at 1 Hz)
Measuring rate
/ sec
200 | 100 | 50 | 25 | 12 | 6 | 3 | 2 | 1
Filter mode 0
Hz
8 ... 0.05 (Low pass filter)
Filter mode 1
8 ... 3 (Low pass filter)
Asynchrone Interface
RS‐485 / 4‐wire
(Cable length up to 500 m)
Baudrate
Baud
1200 ... 115200
Number of bus adresses
max. 32
Summary of Contents for C16i C3
Page 1: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais C16i...
Page 3: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais C16i...
Page 32: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais C16i...
Page 61: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais C16i...