16
Wägezelle
•
Load cell
•
Capteur de pesage
C16A/...
4 Technical data
Type
C16A
Accuracy class according
OIML R 60
D1 (0,033%)
C3 (0,017%)
Max. numbers of load cell
verification intervals (n
LC
)
1000 (10 000 NTEP IIIL)
3000
Max. capacity (E
max
)
t
20
30
40
60
100
20
30
40
60
100
Minimum load cell verification
interval (v
min
)
% of C
N
0.0200
0,010
0,0083 0,0167
Minimum scale verification
(e
min
) to
EN 45 501
(Brackets = max. quantity of
load cells)
kg
5kg
(6lc)
10kg
(10lc)
10kg
(10lc)
10kg
(6lc)
20kg
(10lc)
10kg
(
4lc)
20kg
(10lc)
50kg
(
8lc)
Sensitivity (C
N
)
mV/V
2
Sensitivity tolerance
1)
%
≤
+0.5
1)
Temperature effect on
sensitivity (TK
C
)
2)
% of
C
N
/10K
≤ ±
0.0250
2)
≤ ±
0.0080
2)
Temperature effect on zero
balance (TK
0
)
% of
C
N
/10K
≤ ±
0.0285
≤ ±
0.0140
≤±
0.0116
≤±
0.0234
Hysteresis error (d
hy
)
2)
% of
E
max
≤ ±
0.0330
2)
≤ ±
0.0170
Non-linearity (d
lin
)
2)
% of
E
max
≤ ±
0.0300
2)
≤ ±
0.0180
2)
Creep (d
DR
) in 30 min
% of
E
max
≤ ±
0.0330
≤ ±
0.0167
Input resistance (R
LC
)
(black-blue)
Ω
700
±
20
Output resistance (R
0
)
1)
(red-white)
Ω
706
±
3.5
1)
1)
Smaller tolerances on rated output and output resistance are not necessary. Throughout
corner-pre-adjustment the rated output and output resistance are adapted one to the other, so that scale
indication is within permissible limits when offcenter load is applied.
2)
The data for deviation of non linearity, hysteresis and temperature effect on rated output are typical values.
The sum of these data meets the requirements according to OIML R60 respectively NTEP.
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:[email protected]