Radio Control System 

 
 
 

 

2.2 General 

Safety 

Instructions 

Radio controls facilitate and increase the operating efficiency of cranes and machines. 
Nevertheless, the operator must thoroughly understand and be in a position to properly 
use a radio control system ! 
 

 

Read the Operating Instructions Manual carefully and thoroughly before working with 
the transmitter for the first time ! 

 

The operator undertakes to strictly adhere to the instructions and proceedings 
described in this manual, as well as to follow the general rules and regulations for 
worker safety and accident prevention. Ignoring any such instructions or regulations 
could pose a fatal threat to the operator or others. 

 

Keep this manual on location and readily available at all times ! 

 

Only authorized and properly trained personnel may operate the transmitter. 

 

Anyone who is under the influence of drugs, alcohol or medication that has a 
detrimental effect on a person's reactions may at no time commission, operate, 
maintain or repair the transmitter. 

 

Before switching the transmitter on ensure that no-one is or can be endangered by 
the initiated operation. 

 

With the first signs of any malfunction related to the operative safety and reliability 
of the device the operator must immediately shut down or not activate the 
transmitter. For the purpose of the present manual "shut down" implies : 
–  switching OFF the transmitter, 
–  storing the transmitter in a safe place and ensuring no unauthorized access, 
– de-energizing 

the 

receiver, 

–  unplugging the connection cable on the receiver ! 

 

Defects must be repaired and sources of interference must be removed 
immediately ! 

 

A defective transmitter may only be repaired by qualified and competent personnel. 
Use only original spare parts of HBC-radiomatic GmbH. The use of any other spares 
will render the technical inspectorate approval invalid as well as substantially 
impede operative safety. 

 

Observe all periodical tests and inspections that are required by law or 
recommended in the present operating instructions ! 

 

When using the transmitter always observe the regulations and instructions 
stipulated in the authoritative worker safety and accident prevention regulations. 
–  The transmitter has been manufactured in accordance with the regulations and 

guidelines stipulated in the German Trade Association's "Safety and Accident 
Prevention Regulations for Operating Cranes by Radio Controls" (VBG 9; ZH 
1/547) and pr EN 12077-1. 

–  The transmitter has been tested and approved in accordance with EMC 

guidelines and complies with the authoritative standards for emitted interference 
and interference immunity. 

 

Use the transmitter cautiously and properly. In particular when using a transmitter to 
radio control a machine or crane for the first time. 

 
 

Summary of Contents for spectrum 1 M

Page 1: ...HBC radiomatic GmbH D 74564 Crailsheim Germany Information and specifications subject to change without notice 2003 02 12 Radio Control System HBC Radio Control R Ra ad di io o T Tr ra an ns sm mi it...

Page 2: ...H Haller Stra e 49 53 74564 Crailsheim Germany Tel 49 0 79 51 3 93 0 Fax 49 0 79 51 3 93 50 E mail info radiomatic com http www hbc radiomatic com HBC radiomatic GmbH is not liable for any misprints o...

Page 3: ...ty Instructions 7 3 Operation 8 Automatic Switch OFF APO Function 9 Slewing Gear Release 9 3 1 Battery and Battery Charger 10 3 1 1 FuB 10 AA and FuB 10 XL Transmitter Batteries 10 3 1 2 FLG 110 Batte...

Page 4: ...ntrol system allocated to another crane or machine The radio control system consists of the spectrum 3 transmitter two rechargeable NiCd batteries a memory effect free battery charger and a receiver w...

Page 5: ...disconnected the device from the mains supply supply voltage operating voltage or input terminal voltage Indicates safety relevant passages You will find this pictograph as an indicator for occupatio...

Page 6: ...related to the operative safety and reliability of the device the operator must immediately shut down or not activate the transmitter For the purpose of the present manual shut down implies switching...

Page 7: ...tter off during breaks and after finishing work to avoid any misoperation of crane or machine by unintended activation of the operator controls These precautions are particularly important whenever ch...

Page 8: ...i e the transmitter is operable Important Information After switching ON the transmitter and before operating the crane or machine you must always trigger the acoustic signal by pressing the Horn pus...

Page 9: ...r any disturbances within the working range Automatic Switch OFF APO Function For safety reasons we have equipped the transmitter with an automatic switch OFF APO Automatic Power Off function The tran...

Page 10: ...ture Older batteries lose capacity over time Temperatures under 32 F 0 C have a negative effect on battery charge When handled properly battery can exceed 500 charging cycles Recharge the battery only...

Page 11: ...indicator LED pos LED lights green battery is charging LED blinks green battery is charged i e ready for operation LED lights red battery is deep discharged or defective A discharged battery recharge...

Page 12: ...his is a standard function by radio control systems for construction cranes and available as an option by radio control systems for industrial cranes The transmitter and receiver are equipped with a S...

Page 13: ...2 has control over the crane control system Transmitter 1 is to be given control The operators must continue as follows 1 Enter the pitch command via the rotary switch or pushbutton on transmitter 2 2...

Page 14: ...ansmitter 2 2 Put the key from master transmitter 2 into master transmitter 1 This activates the release for crane pre selection in the transmitter or 3 Remove the key from master transmitter 1 This s...

Page 15: ...FF the slave transmitter 2 Put the key from slave transmitter into master transmitter This activates the release for crane pre selection in the transmitter 3 Select the corresponding crane by means of...

Page 16: ...io Control System 3 2 4 Option infrakey infrakey is an additional infrared module for the transmitter and the receiver Due to separate crane activation via infrared link it increases the safety of ope...

Page 17: ...eiver to the radio receiver 2 Insert a charged battery into the battery compartment of the transmitter 3 Release the STOP pushbutton on the transmitter if locked and turn on the transmitter using the...

Page 18: ...does not react when switched on There is no power Check the battery contacts for damage or contamination Insert a fully charged battery in battery compartment Recharge battery Low power indicator bli...

Page 19: ...l system contact your local distributor or HBC radiomatic GmbH 5 1 In the Event of a Fault Warning Never operate a crane or machine with a faulty or defective radio control system Never try to repair...

Page 20: ...ress over 65 000 combinations Transmitter Specific Technical Data Transmitting power with FuS 671 3 or FuS 680 3 10 mW synthesizer Transmitter antenna internal Battery type standard optional FuB 10 AA...

Page 21: ...ectrum 3 M BE SP3M V2 4 FCC doc Word 2000 FL US MB Page 21 22 HBC radiomatic GmbH D 74564 Crailsheim Germany Information and specifications subject to change without notice 2003 02 12 Radio Control Sy...

Page 22: ...itter spectrum 3 M Page 22 22 BE SP3M V2 3 DOC Word 2000 FL US HBC radiomatic GmbH D 74564 Crailsheim Germany 2002 12 03 Information and specifications subject to change without notice Radio Control S...