Haztec International Ltd ∙ Moorfield Road ∙ Leeds ∙ LS19 7BN ∙ UK
T: +44(0)113 202 9115
∙ [email protected] ∙ www.haztec.uk
8-8114-X EuroMax
Siren PA Amplifier
M352.1.0
- 3 -
November 2021
▪
Relay Outputs
Colour
Connect to
Function
Red (x2) Positive [+]
Common
Orange
As required
Relay output #1
Brown
As required
Relay output #2
➢
Common feed should be supplied by individually fused and suitable rated cables
➢
Each switched output can supply up to a maximum of 10A
▪
Data Logger Output
(only available on certain software versions)
➢
The data logger output replaces relay output #2
➢
Output is present whenever the siren is activated and for all positions of the
volume control for variable volume sirens
➢
Data logger output is not present when in PA or RRB modes
▪
Pre-
selection of minimum volume setting (‘V’ models only)
➢
Turn rotary selector switch to ‘OFF’
➢
Turn volume
control to ‘OFF’
➢
Hold ‘AIR HORN’ switch and button on and turn volume control to ‘ON’
➢
Release both switches ( lights will flash)
➢
Turn rotary switch to the desired tone
➢
Adjust volume control until the required minimum volume is achieved
➢
Press either of the buttons
➢
New setting is stored in memory