Haztec 4-10014 Instructions Download Page 2

Haztec International Ltd ∙ Moorfield Road ∙ Leeds ∙ LS19 7BN ∙ UK 

T: +44(0)113 202 9115 

[email protected] ∙ www.haztec.uk

 

4-10014/10016/10016-D 
Impact LED Warning Light

 

 

  M017.1.2   

 

 

    

 

     - 2 - 

 

 

 

 

   May 2022 

 
 

 

Connection Instructions: 
 

 

Mode 1: 
 

Wire 

Connect to 

Function 

Red 

Positive [+] via switch & fuse 

Main feed 

Black 

Negative [-] 

Earth/Ground 

Pink 

Positive [+] via switch & fuse 

Cruise mode [10% intensity] 

Blue 

See ‘Selecting 

Flash P

attern’

 

Green 

Positive [+] via switch & fuse 

DIM mode [50% intensity] 

Yellow 

See ‘Synchronising 

Multiple L

amps’ 

‘Selecting 

M

ode’

 

 
Mode 2: 

 

Wire 

Connect To 

Function 

Red 

Positive [+] via switch & fuse 

Main feed 

Black 

Negative [-] 

Earth/Ground 

Pink 

Positive [+] via switch & fuse 

Operates zone 1 

Blue 

Positive [+] via switch & fuse 

Operates zone 2 

Green 

Positive [+] via switch & fuse 

DIM mode [50% intensity] 

 

Mode 3 

(external flash controller only):

 

 

Wire 

Connect To 

Function 

Red 

Positive [+] via switch & fuse 

Main feed 

Black 

Negative [-] 

Earth/Ground 

Pink 

Positive [+] via switch & fuse 

Operates zone 1 

Blue 

Positive [+] via switch & fuse 

Operates zone 2 

 

Operating Modes: 
 

 

Before installing the lamp ensure the required mode is set 
 

 

Mode 1

: both zones operate together 

 

Mode 2

: each zone operates independently 

 

Mode 3

: only when operated using an external flasher unit 

 

 

In each mode some wires have different functions. See ‘Connection Instructions’

 

 

Function in each Mode 

Mode 1 

Mode 2 

DIM 

 

 

Cruise 

 

 

Individual zone control 

 

 

Synchronise 

 

 

Flash pattern change 

 

 

 

Summary of Contents for 4-10014

Page 1: ...this product Installation Notes Ensure that the mounting surface is completely flat The lamp is not flexible and will be damaged if any attempt is made to mount on a curved surface Always use the fixing screws provided If a different fixing screw must be used it is essential that the screw head fits comfortably in the screw head recess on the lamp If the screw head is larger than the recess then t...

Page 2: ...gative Earth Ground Pink Positive via switch fuse Operates zone 1 Blue Positive via switch fuse Operates zone 2 Green Positive via switch fuse DIM mode 50 intensity Mode 3 external flash controller only Wire Connect To Function Red Positive via switch fuse Main feed Black Negative Earth Ground Pink Positive via switch fuse Operates zone 1 Blue Positive via switch fuse Operates zone 2 Operating Mod...

Page 3: ...ted mode Once for Mode 1 Twice for Mode 2 Three times for Mode 3 Disconnect the wires To avoid accidentally changing the mode once set insulate the yellow wire Synchronising Multiple Lamps Simultaneous Alternating Flash Set all lamps to the same flash pattern and appropriate phase Lamps set to the same phase will flash simultaneously Lamps set to Phase 1 will alternate will those set to Phase 2 Di...

Page 4: ...d Quad 2 125 3 Double Synchronised Double 1 125 4 Double Synchronised Double 2 125 5 Single Synchronised Single 1 125 6 Single Synchronised Single 2 125 7 Quad Alternating Quad 1 125 8 Quad Alternating Quad 2 125 9 Double Alternating Double 1 125 10 Double Alternating Double 2 125 11 Single Alternating Single 1 125 12 Single Alternating Single 2 125 13 Constant 14 Quad Split Constant 1 125 15 Quad...

Reviews: