Haztec 4-10014 Instructions Download Page 1

Haztec International Ltd ∙ Moorfield Road ∙ Leeds ∙ LS19 7BN ∙ UK 

T: +44(0)113 202 9115 

∙ info@haztec.uk ∙ www.haztec.uk

 

4-10014/10016/10016-D 
Impact LED Warning Light

 

 

  M017.1.2   

 

 

    

 

     - 1 - 

 

 

 

 

   May 2022 

 
 

 

Thank you for purchasing this Haztec product. Before proceeding with installation it is essential 
to read and understand this instruction booklet. 
 

 
 

 

 
 
 
 
 
 
 
 
 

Warning! 
 

 

This product must be installed by persons competent in vehicle electrical installations 

 

Care should be taken to ensure that water ingress cannot occur through mounting or wiring 
holes 

 

Regularly inspect the product to confirm correct operation 

 

DO NOT

 stare directly into the light it produces as permanent damage to the eyes may 

result 

 

Use only a mixture of soap and water to clean this product 

 

DO NOT

 direct a high-pressure water jet at this product 

 

DO NOT

 allow solvents, fuels and acetone-based cleaners etc. to come into contact with 

this product

 

 

Installation Notes: 
 

 

Ensure that the mounting surface is completely flat. The lamp is not flexible, and will be 
damaged  if any attempt is made to mount on a curved surface 

 

Always use the fixing screws provided. If a different fixing screw must be used, it is essential 
that the screw head fits comfortably in the screw-head recess on the lamp 

 

If  the  screw  head  is  larger  than  the  recess  then  the  lamp  lens  will  be  damaged  during 
installation 

 

DO NOT

 over-tighten mounting screws as this will cause damage to the assembly 

 

The  4-10016-D  consists  of  two  lamps  on  a  single  mounting  plate,  therefore  installation 
wiring should be treated as for two individual lamps 

 

Basic Operating Specifications: 
 

Supply voltage range: 

4-10014 

4-10016 

10-30VDC 

10-40VDC 

Maximum current draw: 

0.5A @ 12.5VDC 

1.0A @ 12.5VDC  

Operating temperature range: 

-30°C to +55°C 

 
 

 

Ultra slim LED warning lamp 

 

4 or 6 LEDs [6+6 LEDs for 4-10016-D] 

 

Split into two zones 

 

Zones can have different colours 

 

User selectable flash patterns 

 

Synchronise capable 

 

DIM mode 

 

Cruise mode 

 

R65 versions available [4-10016 only] 

Summary of Contents for 4-10014

Page 1: ...this product Installation Notes Ensure that the mounting surface is completely flat The lamp is not flexible and will be damaged if any attempt is made to mount on a curved surface Always use the fixing screws provided If a different fixing screw must be used it is essential that the screw head fits comfortably in the screw head recess on the lamp If the screw head is larger than the recess then t...

Page 2: ...gative Earth Ground Pink Positive via switch fuse Operates zone 1 Blue Positive via switch fuse Operates zone 2 Green Positive via switch fuse DIM mode 50 intensity Mode 3 external flash controller only Wire Connect To Function Red Positive via switch fuse Main feed Black Negative Earth Ground Pink Positive via switch fuse Operates zone 1 Blue Positive via switch fuse Operates zone 2 Operating Mod...

Page 3: ...ted mode Once for Mode 1 Twice for Mode 2 Three times for Mode 3 Disconnect the wires To avoid accidentally changing the mode once set insulate the yellow wire Synchronising Multiple Lamps Simultaneous Alternating Flash Set all lamps to the same flash pattern and appropriate phase Lamps set to the same phase will flash simultaneously Lamps set to Phase 1 will alternate will those set to Phase 2 Di...

Page 4: ...d Quad 2 125 3 Double Synchronised Double 1 125 4 Double Synchronised Double 2 125 5 Single Synchronised Single 1 125 6 Single Synchronised Single 2 125 7 Quad Alternating Quad 1 125 8 Quad Alternating Quad 2 125 9 Double Alternating Double 1 125 10 Double Alternating Double 2 125 11 Single Alternating Single 1 125 12 Single Alternating Single 2 125 13 Constant 14 Quad Split Constant 1 125 15 Quad...